High Quality Aluminum Core Wire & Cable Low Voltage 0.6/1kv Al/XLPE/PVC AAC ABC AAAC ACSR 4mm2-630mm2

Price $1.00 Compare
Min Order 500 Meters
Shipping From Henan, China
Popularity 264 people viewed
Quantity
+-
 

Henway Electric Group Inc

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
AAAC
Construction, Overhead, Industrial, Power Station, Telecommunication
Low Voltage to High Voltage
DC & AC
Bare
Bare
Round Wire
Aluminum Alloy
ISO, CCC, CE, RoHS
Lhj
Henway
High Quality
ASTM, BS, as, DIN, CSA, IEC, GB/T
Concentric Stranded
Aluminum Alloy
Henway
Wooden Drums, Steel-Wooden Drums, Steel Drums
16mm2 to 2500mm2
China
7614900000
Product Description
Overhead Line Power Transmission Bare All Aluminum Alloy Conductor AAAC

Application:
Aluminum alloy bare conductor is used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristic. Aluminum alloy have higher resistance to corrosion than ACSR and AAC.  It can be used in coastal regions owing to its high degree of corrosion resistance and is also used extensively within the Railway and Metro industries.

Applicable standards:
Aluminum alloy conductor (AAAC) are produced according to ASTM B-399, BS EN-50182, AS/NZS 1531, DIN 48201, CSA 61089, IEC 61089, GB/T 1179, BS 3242, NFC 34-125 or the standards agreed by both of the customers and us.

Advantages
AAAC products have many advantages for use, like low resistance, large carrying capacity, corrosion resistance, easy installation, and so on.

Production Scope:
According to our produce machines, AAC products could up to cross-section 5000 MCM or 2500 mm2,Max. Strand numbers are 127.

Construction:
Aluminum alloy wires, concentrically stranded.


ASTM B-398/B-399 standard:
Code NameTotal AreaStranding and wire diameterApproximate Overall DiameterLinear MassNominal breaking LoadMaximum Resistance at 20ºC 
AWG or MCMmm2mmmmKg/kmdaNΩ/km
Akron67/1.6815.515.0442.74922.15980
 47/1.9621.14 5.89 57.89 6711.58600
Alton48.69(4)7/2.1224.67 6.35 67.56 7831.35570
 27/2.4733.65 7.42 92.14 10690.99870
Ames77.47(2)7/2.6739.26 8.02 107.50 12500.85470
 1/07/3.1253.49 9.35 146.50 16980.62590
Azusa123.3(1/0)7/3. 3762.46 10.11 171.00 19790.53650
 2/07/3.5067.45 10.52 184.70 20480.49740
Anaheim155.4(2/0)7/3.7878.75 11.35 215.16 23980.42640
 3/07/3.9385.00 11.79 232.70 25880.39450
Amherst195.7 (3/0)7/4.2599.20 12.75 271.50 30170.33730
 4/07/4.42107.20 13.26 293.70 32670.31190
Alliance246.9 (4/0)7/4.77125.10 14.30 342.60 38070.26780
 250.0 19/2.91126.70 14.58 346.90 38970.26510
 300.0 19/3.19152.10 15.89 418.60 46770.22060
Butte312.8 19/3.26158.50 16.31 434.00 48760.21120
 350.0 19/3.45177.30 17.25 485.50 52260.18860
Canton394.5 19/3.66199.00 18.31 547.40 58960.16760
  19/3.69202.70 18.44 555.10 59760.16490
 450.0 19/3.91228.00 19.56 624.40 67250.14680
Cairo465.4 19/3.98235.80 19.89 645.70 69550.14310
 500.0 19/4.12253.40 20.60 693.60 74650.13220
 550.0 37/3.10278.70 21.67 762.90 83840.12000
Darien559.5 19/4.36283.50 21.79 776.30 83550.11810
 660.0 37/3.23304.00 22.63 832.00 91430.11050
 650.0 37/3.37329.40 23.57 909.80 99030.10150
Elgin652.4 19/4.71330.60 23.55 970.60 97430.10120
 700.0 37/3.49354.50 24.46 910.60 101930.09464
Flint740.8 37/3.59375.40 25.15 1028.00 107930.08944
Code NameTotal AreaStranding and wire diameterApproximate Overall DiameterLinear MassNominal breaking LoadMaximum Resistance at 20ºC 
AWG or MCMmm2mmmmKg/kmdaNΩ/km
 750.0 37/3.62380.20 25.32 1041.00 109920.08796
 800.0 37/3.73405.40 26.14 1109.00 116910.08285
 900.0 37/3.96456.30 27.74 1249.00 131910.07351
Greeley927.2 37/4.02469.80 28.14 1287.00 135910.07133
 1000.0 37/4.18506.70 29.24 1388.00 145890.06597
 1077.4 61/3.38483.40 30.42 1496.00 155890.06120
 1165.1 61/3.51523.70 31.59 1617.00 168880.05675
 1250.0 61/3.63633.30 32.67 1733.00 179870.05306
 1259.6 61/3.65564.00 32.85 1748.00 181870.05248
 1348.8 61/3.78604.20 34.02 1872.00 194860.04893
 1439.2 61/3.90644.50 35.10 1997.00 207850.04597
 1500.0 61/3.98760.00 35.82 2081.00 216840.04414
 1750.0 61/4.30886.70 38.70 2429.00 252820.03781

Products Pictures

Packing and loading containers pictures:

* We can design and produce ACSR according to client's requirement. Any requirement, feel free to contact us!

Company Information


Certification


FAQ


1. Q:How does your factory control the quality?

A:Factory has a quick and enthusiastic merchandisers team, strict and responsible QC team, service for many well-known brands all around the world with our high-quality products and strict.

2. Q:Can I visit your company?

A: Sure,If you need,we will arrange the driver to pick you up.

3. Q:How can I get some samples?

A: Contact me on below,Determin sample and address for shipping.

4. Q:Have you ever supplied cables to our country?

A:  Henway Cables have been sold to over 100 countries and regions in the world. you can contact me for details.

5. Q:What is your MOQ?

A: MOQ Normally 500 meters for big diameter cables. Please contact me for detail info if you have specific cable requirement.

6.  Q:When can I get the price?

A: Usually quote within 6 hours after we get your inquiry.

7. Q:How long is your delivery time?

A: According to your order's quantity. Usually our lead time is 3 - 20 working days.
 

For more information about wires and cables, please feel free to contact us. Your inquiries will be replied to within 6 hours!!