- Internal Suction Structure: High speed homogenizer adopts internal suction homogenizing structure, which can carry out efficient homogenization, emulsification and extraction of trace organic compounds in water, lipid solubles and soluble organic solvents between two immiscible liquids.
- Application: Homogenizer can make the cell membrane rupture to the nuclear separation, and can be used at different speeds to make the DNA strand break, or make the large molecules into small molecules of material fracture.
- Working Mode: This high speed homogenizer can work continuously for no more than 3 minutes at a time. It is generally recommended to play for 1?2 minutes to pause for 1?2 minutes, which can be repeated several times.
- Button Adjustment:The working speed of the homogenizer can be adjusted by rotating the button. When used at high speed. It can make all kinds of animal and plant tissues to achieve the purpose of uniform mixing. When used at low speed, it can be used as a mixer.
- Homogenizing Function: The high speed homogenizer has a suction homogenizing function. It can emulsify the efficient homogenization between two immiscible liquids and emulsify the trace organic matter in water. Extraction of soluble substances and organic solvent soluble substances.


Product Model | SAH500S-H 50G | SAH500S-H 70G | SAH500S-H 90G |
Voltage | AC220V 50/60Hz | AC220V 50/60Hz | AC220V 50/60Hz |
Input Power | 850W | 850W | 1350W |
Output Power | 500W | 500W | 800W |
Rated Torque | 34.1N.cm | 34.1N.cm | 69.5N.cm |
Working System | S1(Continuity) | S1(Continuity) | S1(Continuity) |
Operation Control Method | Combined control knob | Combined control knob | Combined control knob |
Speed Adjustment Range (no load) | 1000-14000rpm | 2000-14000rpm | 2000-11000rpm |
Speed Control Type | Infinity | Infinity | Infinity |
Digital Revolution Indicator | LED(Digital) | LED(Digital) | LED(Digital) |
Max. Torque of Working Head | 34N.cm | 34N.cm | 69.5N.cm |
Max. Linear speed of Rotor | 16m/s | 20.5m/s | 22m/s |
Working Head Material | SS 316L Stainless Steel | SS 316L Stainless Steel | SS 316L Stainless Steel |
Working Head Diameter | 50mm | 70mm | 90mm |
Min./Max. Immersion Height | 50/236mm | 50/236mm | 50/236mm |
Stator Standard Configuration | Square hole/long hole/inclined hole | 5mm²/20mm²/50mm² | 5mm²/20mm²/50mm² |
Processing Capacity (H2O) | 300-20000ml | 500 ~ 40000ml | 800-60000ml |
Max. Processing Viscosity | 8000mPa.s | 8000mPa.s | 8000mPa.s |
Allowable Ambient Temperature | less than 40 ºC | less than 40 ºC | less than 40 ºC |
Allowable Relative Humidity | less than 80% | less than 80% | less than 80% |
Timing Control Range | 1-1000min | 1-1000min | 1-1000min |
Machine Size | 215*310*720mm | 215*310*720mm | 215*310*720mm |
Machine Weight | 9.2kg | 9.2kg | 10.8kg |
Model | JRJ300-D-1 | JRJ300-SH(digital display) |
Input power | 500W | 500W |
Output power | 300W | 300W |
frequency | 50/60HZ | 50/60HZ |
Rated power supply | AC220V | AC220V |
Speed range | 300-11000rpm | 300-11000rpm |
noise | 79dB | 79dB |
operation temperature | <120ºC | <120ºC |
Processing capacity(H2O) | 40L | 40L |
Working head diameter | Ф70mm | Ф70mm |
Total length of work head | 260mm | 260mm |
Immersion depth of material | 200mm | 200mm |
Suitable volume | 200-40000ml(H2O) | 200-40000ml(H2O) |
Applicable viscosity | <5000cp | <5000cp |
Stator configuration | 5mm2,20mm2,50mm2 | 5mm2,20mm2,50mm2 |


The production of the Pyroceram Top Hotplate introduce
1.Start by the blanking process for the metal part
The part was beginning as the blanking
1.Laser blanking machine capacity :8000*2000*10mm
2.We had about 15 pcs of the laser cutting machine in blanking workshop ,name from No1 to No 15,
3.6S fully carry out in our workshop according to the iso13485,
4.All of the raw material can be Traceability

To form the metal part into the shape we need ,the first part was by the bending press and the bending die


need the bracket for the motor and metal stamping part for the housing and electric connect part,The progressive die stamping can give out the huge volume and low cost for the LED Digital Hotplate Overhead Rotor stator Homogenizers Hot Plate with Ceramic Coated Lab Hotplate, 280ºC Stir Plate, Overhead Mixer 3,000mL Stirring Capacity, 200-1500rpm, Stirring Bar Lab Equipment machine spare metal part.
1.QTY of the welding robot :23pcs
2.Capacity of the welding robot :500A
3.Work station:2000*1500mm


We had about 10 sets of the plastic injection work for the Laboratory Thermostatic Heater machine.
1.The capacity for plastic injection machine was :1000*850*750mm
2.The max ton for plastic injection machine was 1000T
1.We need to know how many part in our warehouse
2.We need to anticipate the part when to full fill in for all the benchtop Laboratory Thermostatic Heater with Drying Function Water Storage Tank


1.CNC QTY:15PCS
2.Tolerance for CNC machine :0.01mm



9.Electric part assemble to the Multifunction Steam Sterilization Machine workshop,the plc or the other computer control part connect to the machine before move to the next production procss.




Customer review our Laboratory Rotor stator Homogenizers Machine workshop,We were welcome all of our customer to visit our company to review and test the ultrasonic homogenizer for Organisms, Medical, Chemistry,Our business vision was :long term business ,win-win for the future
The over sea customer always concern about the packing and loading for the High Shear Emulsifier Homogenizer with Time Setting High Shear Emulsifier Homogenizer Machine,we cant bear the lost for tiny mistake for the Vacuum Steam Machine machine ,one mistake will cause the machine broken or cant work .From the packing for Laboratory Medical Sterilization Machine to the container loading detail show as below
Warehouse and stroage for the medical Medical Sterilization Machine,the temperature should be control within 18-25° for all equipment and test machine ,all the record can trace within 3 years.


The maintain and repair guarantee for the Medical Sterilization Machine workshop was the key to the business ,when a customer bought a machine from us ,the guarantee was the most importance things customer concern.we sent out technical service team to oversea customer site for the maintain and repair for our customer .Our service for the lab equipment was not stop after the Vacuum Steam Machine Machine sold ,it was the start for our company and your company for win win situation .You use the Vacuum Steam Machine Machine we take care of the rest.



We take part into the MedtecChina Canton Fair (The China Import and Export Fair) exhibition every year ,hope one day we can meet each on the fair
The supplier and the customer was togeher for the future ,both parties should be in win-win situation ,so we were looking forwarder to hold hand by hand for bright future.
he compact digital homogenizer unit includes a high-watt motor Utilized speed regulation with six different speed levels for accurate speed adjustment Designed with a digital control interface allows users to precisely set and monitor parameters Fitted with reusable sample tubes that come with specialized attachments or beads for effective homogenization Improved ABS and aluminium die-casting materials are used in the body's construction Built-in with safety features to reduce exposure to dangerous materials and prevent sample contamination Easily adjustable with simple cleaning Minimal maintenance with safety and long-term usability
Item Type: Adjustable High Speed Homogenizer
Material: ABS
Motor Speed: 22000 rpm
Homogenizing Knife 1: 8000-18000 rpm
Homogenizing Knife 2: 8000-20000 rpm
Power: 185W
Continuous Working Time: 3 minutes
How to Use:
Direct installation and use.
packing list:
1 x Homogenizer
1 x Instruction Manual
4 x Measuring Cup
2 x Stand
3 x Fixture
4 x Accessories
Note:
1. The instrument should be placed on the horizontal worktable, the installation of the required homogenizing tool must be in place, turn on the power to try the machine first with a cup or vessel containing water, so that the pentalobe cutter head is submerged in the water, open the power switch, there is a slow to fast to adjust the speed knob, there is no clear metal friction sound (such as metal friction sound, shut off the power, loosening expenditure cutter 6M/M support tightening screw, the external fixed set of randomly steering up to the installation of in place, and then tighten) can work only after the completion of the work. If there is no metal friction sound, turn off the power, loosen the 6M/M support screw of the cutter and install the outer fixing sleeve in place randomly.
2. Cut the plants or microorganisms to be experimented into small pieces or , put them in the randomly equipped glass ware, clamp them in the middle of the magnet bracket (heptagonal), loosen the 8M/M fastening screws of the fixed motor base, slowly move downward against the mouth of the vessel, make the homogenizing head 23mm from the bottom of the vessel as well, and then tighten the 8M/M screws.