High Voltage Application Insulation Material Glass Insulator

Price $5.00 Compare
Min Order 100 Pieces
Shipping From Shanxi, China
Popularity 371 people viewed
Quantity
+-
 

Qianhong Technology (Shanxi) Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
Glass suspension insulators
High-voltage, High-temperature
FRP/GRP
Suspension Insulator
A Type Insulator
High Voltage Power Transmission, Insulation, Electrical Installation
Trough Type
160KN
ISO9001
Green
Qianhong
Glass Insulator
Standard Type, Dirt Resistant Type, Multi-Umbrella
Selectable
Acceptable
Wooden Box Packaging
5.8kg
China
Product Description

Product introduce

Product Operating Performance
 

1. Spontaneous detonations at insulation value, convenient for visual inspections
2. Good arc resistance performance

3. Good self-cleaning performance and not easy to age
4. Large main capacitance and uniform voltage distribution
5. Good vibration fatigue resistance performance
6. Excellent anti-icing performance
7. Excellent sand-proof and anti-U.V.performance
8. Reliable performance of transmission lines, ensure no string breakage failures occur
9. Low spontaneous detonation rate for product annual operation


Standard Profile


CATALOG No
 
UG40B110/200NUG70B146/320NUG100B127/320N
UG100B146/320N
UG120B127/320N
UG120B146/320N
UG160B146/400N
UG160B155/400N
UG160B170/400N
Mechanical Performance
Min.Mechanical failing load(KN)4070100120160
Dimensions
Nominal diameter D(mm)178255255255280
Nominal spacing P(mm)110146127/146127/146146/155/170
Nominal creepage distance(mm)190320320320400
Standard coupling1116161620
 

CATALOG No
 
UG210B170/400NUG240B170/400NUG300B195/485NUG400B205/550N
UG420B205/550N
UG530B240/635N
UG550B240/635N
Mechanical Performance
Min.Mechanical failing load(KN)210240300400/420530/550
Dimensions
Nominal diameter D(mm)280280320360380
Nominal spacing P(mm)170170195205240
Nominal creepage distance(mm)400400485550635
Standard coupling2020/24242832

Antipollution-type
CATALOG NoUG70B146/400HUG70B146/450HUG70B146/550HUG100B146/400HUG100B146/450H
Mechanical Performance
Min.Mechanical failing load(KN)707070100100
Dimensions
Nominal diameter D(mm)255280330255280
Nominal spacing P(mm)146146146146146
Nominal creepage distance(mm)400450550400450
Standard coupling1616161616
 
CATALOG NoUG100B146/550HUG120B146/400HUG120B146/450HUG120B146/550HUG120B146/620H
Mechanical Performance  
Min.Mechanical failing load(KN)100120120120120
Dimensions  
Nominal diameter D(mm)330255280330330
Nominal spacing P(mm)146146146146146
Nominal creepage distance(mm)550400450550620
Standard coupling1616161616
 

CATALOG No
 
UG160B155/450H
UG160B170/450H
UG160B146/550H
UG160B155/550H
UG160B170/550H
UG160B155/620H
UG160B170/620H
UG210B170/450HUG210B170/550H
Mechanical Performance  
Min.Mechanical failing load(KN)160160160210210
Dimensions  
Nominal diameter D(mm)280330330280330
Nominal spacing P(mm)155/170146/155/170155/170170170
Nominal creepage distance(mm)450550620450550
Standard coupling2020202020
 
CATALOG NoUG240B170/450HUG240B170/550HUG300B195/595HUG300B195/635HUG300B195/690H
Mechanical Performance  
Min.Mechanical failing load(KN)240240300300300
Dimensions  
Nominal diameter D(mm)280330320360380
Nominal spacing P(mm)170170195195195
Nominal creepage distance(mm)450550595635690
Standard coupling2424242424
 
CATALOG NoUG400B205/630HUG420B205/630HUG530B240/720HUG550B240/720H
Mechanical Performance 
Min.Mechanical failing load(KN)400420530550
Dimensions 
Nominal diameter D(mm)360360380380
Nominal spacing P(mm)205205240240
Nominal creepage distance(mm)630630720720
Standard coupling28283232

Tri-shed type
CATALOG NoUG70B146/450DUG100B146/450DUG120B146/450DUG160B155/550T
UG160B170/550T
UG210B170/550T
Mechanical Performance  
Min.Mechanical failing load(KN)70100120160210
Dimensions  
Nominal diameter D(mm)280280280330330
Nominal spacing P(mm)146146146155/170170
Nominal creepage distance(mm)450450450550550
Standard coupling1616162020
 
CATALOG NoUG240B170/550TUG300B195/550TUG300B195/635TUG420B205/635TUG550B240/635T
Mechanical Performance  
Min.Mechanical failing load(KN)240300300420550
Dimensions  
Nominal diameter D(mm)330330380/400380/400380/400
Nominal spacing P(mm)170195195205240
Nominal creepage distance(mm)550550635635635
Standard coupling2424242832

Aerodynamic Type
CATALOG NoUG70B127/365A
UG70B146/365A
UG100B127/365A
UG100B146/365A
UG120B127/365A
UG120B146/365A
UG160B146/380A
UG160B155/380A
UG160B155/550A
UG160B170/550A
Mechanical Performance  
Min.Mechanical failing load(KN)70100120160160
Dimensions  
Nominal diameter D(mm)380380380420450
Nominal spacing P(mm)127/146127/146127/146146/155155/170
Nominal creepage distance(mm)365365365380550
Standard coupling1616162020
 
CATALOG NoUG210B170/380AUG240B170/380AUG300B195/550AUG420B205/550A
Mechanical Performance 
Min.Mechanical failing load(KN)210240300420
Dimensions 
Nominal diameter D(mm)420420455455
Nominal spacing P(mm)170170195205
Nominal creepage distance(mm)380380550550
Standard coupling20202428

Ground-wire Type
CATALOG NoUGE70CUEC70CNUEG100CUEG100CNUEG120CUEG120CN
Mechanical Performance   
Min.Mechanical failing load(KN)7070100100120120
Dimensions   
Nominal diameter D(mm)200200200200200200
Nominal spacing P(mm)210210210210210210
Nominal creepage distance(mm)220220220220220220
Standard coupling16C16C16C16C16C16C
Suspending modesSuspensionTensionSuspensionTensionSuspensionTension

 
Company Profile

Qianhong Technology (Shanxi) Co., Ltd., established in December 2023, is an emerging manufacturing company specializing in the design, production, and sales of high-quality tempered glass insulators. The company is located in Caojiazhuang Village, Gucheng Town, Xiangfen County, Linfen City, Shanxi Province and has newly,built two glass insulator production lines with state-of-the-art domestic technology and an annual output of 10 million tempered glass insulators. The company produces 40KN to 530KN standard tempered glass insulators, 70KN to 530KN anti-pollution tempered glass insulators, 70KN to 300KN aerodynamic tempered glass insulators as well as double-umbrella and multi-umbrella tempered glass insulators with anti-pollution capabilities, Fully meeting the needs of transmission line construction for various voltage levels.

The company has passed the IS0900l International Quality Management System IS01400l International Environmental System Certification and IS045001 0ccupational Health Management System Certification and is committed to providing stable and reliable tempered glass insulators for the power transmission of electricity systems. Since its establishment, the company has always adhered to the principle of "quality first, customer foremost, serving society and benefiting the local", ensuring that each product meets or exceeds customer expectations through continuous technological innovation and stringent quality management.

Corporate culture is one of our company's core competencies. We advocate the corporate spirit of "teamwork, integrity, innovation, and striving for excellence", encouraglng employees to give full play to their talents while focusing on team collaboration. By creating an open environment for communication and offering continuous professional development opportunities, we are committed to providing employees with a good working environment and growth space, jointly promoting the sustainable and healthy development of the company.

In the future, Qianhong Technology (Shanxi)Co., Ltd. will continue to be market-oriented, adhere to the philosophy of high quality and innovation-driven development, optimize the production line based on the basic performance of the products and strive to become an advanced company in the industry of tempered glass insulators.

 
Our factory

 

Certifications

 

Exhibition

 

FAQ

 

PRODUCT CHATACTERISTICS
1. What are the advantages of glass insulators?
Glass insulator has zero value self-explosion characteristics, when the insulator deteriorates and loses insulation performance, it will automatically break, which is convenient for operation and maintenance personnel to find and replace in time to ensure the safety of the line. Its mechanical strength is high, can withstand large tensile force, pressure and bending moment and other mechanical loads, adapt to different line conditions. The surface is smooth, not easy to accumulate pollution, compared with other insulator types in the same environment, the pollution lightning voltage is higher, has good anti-pollution performance, and excellent aging resistance, can maintain stable insulation and mechanical properties in long-term operation, long service life, usually up to 30-40 years or even longer.

2. What are its disadvantages?
Glass insulators are relatively heavy and may require more human and material resources during transportation and installation. Its production process is more complex, high requirements for raw materials and manufacturing technology, resulting in the cost may be slightly higher than some other insulators. And once the self-explosion, the glass fragments may fall, there is a certain safety risk to the people and objects below, but now there are also some anti-debris design and measures are gradually applied.

INSTALLATION AND MAINTENANCE
1. What should I pay attention to during installation?
Before installation, check the appearance of the glass insulator to ensure that there are no cracks, damage or other defects. Handle with caution during installation to avoid damage caused by collision. Install the fittings correctly according to the design requirements to ensure the connection is firm and reliable, and strictly control the tilt Angle and tension of the insulator string during installation to ensure uniform force.

2. How to perform routine maintenance?
Perform regular inspection to check for self-detonation, flashover traces, or other anomalies. For dirty areas, timely cleaning can be arranged according to the degree of pollution, generally using water flushing or special electric cleaning equipment. The temperature distribution of insulators is detected by infrared temperature measurement and other technical means to determine whether there is abnormal heating phenomenon such as local overheating. If deterioration or damage is found, it should be recorded in time and arranged for replacement.

TECHNICAL PARAMETERS
1. What are the main technical parameters?
It mainly includes the rated voltage, which determines the voltage level of the power system applicable to the insulator; Mechanical failure load, which represents the maximum mechanical force that the insulator can withstand; Creepage distance affects the anti-fouling performance of insulators. The longer the creepage distance, the stronger the anti-fouling ability; There are also parameters such as insulation resistance and capacitance value, which reflect the insulation performance and electrical characteristics of the insulator. Lines with different voltage levels and application scenarios have different requirements for these technical parameters of glass insulators.

2. How to select the glass insulator with appropriate parameters according to the line requirements?
First, the rated voltage of the insulator is determined according to the voltage level of the line to ensure that it can meet the insulation requirements of the system. According to the mechanical load of the line, such as wire self-weight, tension, wind load, ice load, etc., choose the insulator with the appropriate mechanical damage load, and generally leave a margin. Considering the pollution degree of the environment where the line is located, choose products with sufficient creepage distance. For example, in heavily polluted areas, anti-pollution glass insulators with long creepage distance should be selected, and other relevant parameters should be comprehensively determined in combination with local climate conditions to ensure that the insulator can operate stably on the line for a long time.
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA