FXBW12/100
High-voltage, Low-voltage, High-temperature
Composite Polymer
Suspension Insulator
A Type Insulator
High Voltage Power Transmission, Insulation, Driving, Electrical Installation
Trough Type
100KN
CCC, CE, ISO9001
Grey/Red/Customers' Requirements
SAA Grid
12kv
334mm
3~20 Days
Fiber Glass Core
HDG Steel
SAA GRID
Carton or Plywood Case
Customers' Requirements
China
85469000
Product Description
Application: Used on surge arrester, circuit breaker, capacitor, instrument transformer, power transformer, cable termination & GIS, etc.
Color: Red, Brown, Gray or Customer's requirement
Standard: IEC, GB, BS, ANSI, AS or Customer's requirement
Color: Red, Brown, Gray or Customer's requirement
Standard: IEC, GB, BS, ANSI, AS or Customer's requirement




Rated System Voltage (kV) | Type | Section Length (mm) | Arcing Distance (mm) | Creepage Distance (mm) | Coupling Size | Specified Mechanical Load (kN) | Lightning Impulse Withstand Voltage (kV) | Power Frequency Withstand Voltage (kV) | |
Dry | Wet | ||||||||
10 | FXBW-10/70 | 310 | 160 | 350 | 16 | 70 | 75 | 42 | 38 |
35 | FXBW-35/70 | 670 | 505 | 810 | 16 | 70 | 230 | 106 | 95 |
66 | FXBW-66/70 | 870 | 765 | 1920 | 16 | 70 | 410 | 230 | 185 |
66 | FXBW-66/120 | 870 | 745 | 1920 | 16 | 120 | 410 | 230 | 185 |
110 | FXBW-110/70 | 1240 | 1220 | 3520 | 16 | 70 | 550 | 285 | 230 |
110 | FXBW-110/120 | 1240 | 1220 | 3520 | 16 | 120 | 550 | 285 | 230 |
110 | FXBW-110/160 | 1340 | 1180 | 3520 | 20 | 160 | 550 | 285 | 230 |
220 | FXBW-220/120 | 2240 | 2220 | 7040 | 16 | 120 | 1000 | 440 | 395 |
220 | FXBW-220/160 | 2240 | 2200 | 7040 | 20 | 160 | 1000 | 440 | 395 |
220 | FXBW-220/210 | 2240 | 2200 | 7040 | 16 | 120 | 1000 | 440 | 395 |
330 | FXBW-330/120 | 2930 | 3050 | 10560 | 16 | 120 | 1425 | 630 | 570 |
330 | FXBW-330/160 | 2930 | 3050 | 10560 | 20 | 160 | 1425 | 630 | 570 |
330 | FXBW-330/210 | 2930 | 3050 | 10560 | 20 | 210 | 1425 | 630 | 570 |
500 | FXBW-500/120 | 4050 | 4600 | 16000 | 16 | 120 | 2050 | 820 | 740 |
500 | FXBW-500/160 | 4050 | 4600 | 16000 | 20 | 160 | 2050 | 820 | 740 |
500 | FXBW-500/210 | 4050 | 4600 | 16000 | 20 | 210 | 2050 | 820 | 740 |
500 | FXBW-500/300 | 4450 | 4500 | 16000 | 24 | 300 | 2050 | 820 | 740 |
500 | FXBW-500/420 | 4450 | 4500 | 16000 | 28 | 420 | 2050 | 820 | 740 |
750 | FXBW-750/120 | 7150 | 6750 | 23500 | 16 | 120 | 2700 | 1160 | 1050 |
750 | FXBW-750/210 | 7150 | 6750 | 23500 | 20 | 210 | 2700 | 1160 | 1050 |
750 | FXBW-750/300 | 7150 | 6750 | 23500 | 24 | 300 | 2700 | 1160 | 1050 |
750 | FXBW-750/420 | 7150 | 6750 | 23500 | 28 | 420 | 2700 | 1160 | 1050 |
750 | FXBW-750/550 | 7150 | 6550 | 23500 | 32 | 550 | 2700 | 1160 | 1050 |
1000 | FXBW-1000/210 | 9000/9750a | 8500 | ≥32000 | 20 | 210 | 3200 | 1440 | 1300 |
1000 | FXBW-1000/300 | 9000/9750a | 8500 | ≥32000 | 24 | 300 | 3200 | 1440 | 1300 |
1000 | FXBW-1000/420 | 9000/9750a | 8500 | ≥32000 | 28 | 420 | 3200 | 1440 | 1300 |
1000 | FXBW-1000/550 | 9000/9750a | 8300 | ≥32000 | 32 | 550 | 3200 | 1440 | 1300 |
Order Information: 1.Pollution level; 2.Voltage grade; 3.Mechanical load; 4.Insulation distance; 5.Creepage distance; 6.Section length; 7.Coupling type Ps. Different design could be supplied as customer requirements |







1.Do you accept OEM or ODM?
Yes,we're a factory, any customized requirements we will try our best to help you realize.
2. How does your factory do regarding quality control?
All the products will be 100% checked before the shipment and we have passed through the QC System.
3.CAN YOU PROVIDE SAMPLES?
Yes, plesae contact us to know the sample policy.
4.Usual Payment Term.
We accept terms of T/T in advance, L/C, Western Union and others.
Any question, please ask us!
5. Can I visit your company or factory?
Of course, you are welcome.