Highpeak Advanced Digital Temperature Sensor for Extreme Conditions Use

Price $387.00 Compare
Min Order 1 Piece
Shipping From Shanghai, China
Popularity 259 people viewed
Quantity
+-
 

Cold Valley Intelligent Technology (Shanghai) Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
Tiankang temperature transmitter
Wall-Mounted Current Type
Temperature
LCD
Not Site Display
0.1
IP65
CE
Customized
Highpeak
Wooden
China
90262010
Product Description

Welcome to the revolution in temperature monitoring with our High-Performance Temperature Transmitter. Skillfully engineered to integrations across an array of display instruments, recording devices, and sophisticated electronic computers, this transmitter is your ultimate ally. Delivering a steadfast 4~20mA output, it excels in accurately gauging temperatures across an extraordinary -200ºC to 1300ºC range, encompassing liquids, steam, gaseous media, and solid surfaces. Perfectly suited for environments dealing with explosive materials like carbon chlorides, it ensures safety and precise monitoring, reinforcing your production processes with unmatched reliability.

Experience unparalleled performance with our temperature transmitter's sturdy two-wire system! Not only does it guarantee a 4~20mA output, but it also showcases remarkable resistance to interference, offering precision and dependability even in the most demanding conditions.

Discover the brilliance of our groundbreaking design-significantly diminishing the necessity for compensation wires, our temperature converter saves you considerably on both material and installation costs. Embrace efficiency and cost-effectiveness like never before.

Choose safety, reliability, and longevity with our temperature transmitter. Celebrated for its enduring service life, it stands as a steadfast choice for applications demanding unwavering dependability over time.

Marvel at the sophistication of our transmitter, featuring automatic cold junction temperature compensation and a nonlinear correction circuit. It guarantees uninterrupted, precise performance, effortlessly adapting to a myriad of conditions to keep your operations running smoothly.
Product Parameters

Thermocouple

Model  Graduation
Tolerance level
II1
 
Range of temperature
    measurement ºC


Tolerance value

Range of temperature
measurementºC



Tolerance value
WRNK -40~+375±1.5ºC-40~+333±2.5ºC
 375~1000±0.004Itl333~1200±0.0075Itl
WRM
 
WRE

N

E
 -40~+375±1.5ºC-40~+333±2.5ºC
 375~1000
-40~+375
±0.004ltl
±1.5ºC
333~1200
-40~+333
±0.0075ltl
±2.5ºC
 375~800±0.004ltl333~900±0.0075ltl
WRFJ -40~+375±1.5ºC-40~+333±2.5ºC
 375~750±0.004Itl333~750±0.0075Itl
WRCT -40~+125±0.5ºC-40~+133±1.0ºC
 125~350±0.004ltl133~350±0.0075ltl
Thermal resistance
 
ModelGraduationRange of temperature measurementºCPrecision gradeAllowable deviation
WZPBPt100-200~+500A±(0.15+0.002ltl)
B±(0.30+0.005Itl)
WZCBCu50,Cu100-50~+100--±(0.30+0.006ltl)
Output signal4~20mA.load resistance 250,res4istance of the transmission conductor is 1000.
Output methodSecond-tier system
Precision gradePrecision level of temperature transmitter:0.2;0.1;0.5
Display precision grade:Analog indicator 2.5 Digital display type 1
Power supply24V.DC±10%Protection levellp65

Explosion-proof grade
 Explosion-proof:dIIBT4,dICT5,dIICT6
Essentially safe type:iaIICT6
Insulation resistanceThe insulation resistance between the instrument output terminal and the enclosure shall be not less than 50MQ.
Thermal response time
When the change of phase step appears,the current output signal of the meter changes to the time which is equivalent to
50%of the step change Generally,T0.5is used to show that the stability time of phase step of the temperature transmitter is
not more than one fifth of the stability time of thermal response r0.5,the thermal response time of a thermocouple
(resistance)is used as the thermal response time of the instrument.When the stability time of phase step of the
temperature transmitter is not more than half of the stability time of thermal response T0.5,the thermal response time of
temperature transmitter is used as the thermal response time of the instrument.
Basic errorThe basic error of the instrument should not exceed the synthetic error of the basic error of thermocouple (resistance)and
temperature transmitter.
Company Profile
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. stands proudly as a distinguished arm of the esteemed Hanshan (Cold Mountain) Intelligent Technology Co. Upholding a legacy marked by innovation and excellence, we represent the pinnacle of intelligent technology solutions.
The illustrious Hanshan Intelligent Technology Co., Ltd. embarked on a remarkable journey in the bustling city of Shanghai in 2013, quickly establishing its reputation as a vanguard in the arena of intelligent technology.
Our foundation is bolstered by a team of industry veterans hailing from elite international automation firms, each member bringing over two decades of unparalleled experience in automation and engineering. With a focused decade dedicated to the consultation and implementation of cutting-edge digital solutions, our objective is clear: to deliver premier automation and digitization products and services to a global clientele. Strategically based in the vibrant city of Shanghai, China, we are poised to make a significant impact.
With a legacy spanning over twenty years in the petrochemical sector, our profound understanding of automation and digitization spans the entire industry spectrum-from upstream to downstream. We proudly extend our expertise to offer specialized products, comprehensive solutions, and life cycle services across sectors such as petroleum, chemicals, electric power, biomedicine, APIs, food & beverages, liquor, metallurgy, and non-ferrous metals, ensuring exceptional quality and proficiency.


 
FAQ

How do I select the right product?
A:Upon receipt of your inquiry, we will provide you with a comprehensive technical document. This will enable you to verify the detailed process parameters and technical specifications required. Based on your specific requirements, we will then recommend the most suitable model.

I would like a confirmed model. Can you provide that?
A:Certainly. Once you send us the model you require, we will first need to verify the suitability of the model. If necessary, we will provide some more cost-effective optimization suggestions. After confirmation, we can proceed with a formal quotation.
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA