Profile Certified by SGS/BV
AT5010 DN80 Dual Flange Level Transmitter
Differential Pressure Transmitter
Mono-Crystalline Silicon
Fluids Compatible with Contact Material
±0.2%, ±0.1% Upper Limit
-100 Kpa to 1 MPa (Minimum Range 0 to 10 Kpa)
IP67
Sil2/3, Nace, Nepsi, Atex, CE
Customized
4 to 20 Ma + Hart 7, Modbus-RTU/RS485 and Others
2-Year/3-Year Warranty
DN80 and Other Customized Sizes
HollySys
Transported in Standard Packaging
18 cm*18 cm*25 cm
China
9026201090
Product Description


Introduction
With internationally leading monocrystalline silicon sensor technology and patented packaging process, AT5010 differential pressure remote transmitter is a high-performance pressure transmitter. The monocrystalline silicon sensor is located at the top of the metal body, away from the contact surface of the medium, to achieve mechanical isolation and thermal isolation. The sintered glass integrated sensor leads achieve high-strength electrical insulation with a metal matrix, improving the electronic circuit's flexible performance and ability to withstand transient voltage protection. The monocrystalline silicon sensor packaging technologies ensure that AT5010 differential pressure remote transmitter can handle complex chemical and mechanical loads while providing strong electromagnetic interference resistance for demanding industrial environment applications.

Features
·  SIL2/3, NACE, NEPSI, ATEX, CE
·  -100 kPa to 1 MPa (minimum range 0 to 10 kPa)
·  4 to 20 mA + HART 7, Modbus-RTU/RS485 and others
·  ±0.2% upper limit, ±0.1% upper limit accuracy (special tailor-made)
·  Maintainable within 0.1% over a period of 10 years in the URL
·  Static pressure up to 40 MPa
·  Protection level: SIL2/3, Ex ia IIC T4 Ga, Ex db IIC T4...T6 Gb, IP67
·  Intuitive interface and built-in buttons for quick commissioning of the device
·  316L/HC/Tantalum/316L coated with PTFE/316 L gold plated
·  Multiple standard process connections, as well as filler fluids, enabling connection to various forms of piping
·  Combination of more complex level and volume flow measurements possible
·  Convenient and user-friendly, wide options in forms and material
·  Isolation diaphragms with the unique design, featuring anti-overloading
·  Intelligent diagnosis, self-diagnosis, sensor diagnosis, and process variable diagnosis
·  Electrical interface titled down by 10°, which can effectively avoid water inflow caused by improper installation
·  Innovative calibration algorithm, which guarantees accurate measurement of a sensor in a wide temperature range

Applications
Pressure, level, differential pressure, density, interface and flow rate

Product Images
Technical Specifications
DN80 Dual Flange Level Transmitter
Parameter ClassSpecification CodeClarification
AT5010 DN80 dual flange liquid level transmitter (accuracy ±0.2% FS)
Sensor typeYDPMonocrystalline silicon sensor (gauge pressure -100 kPa to 1 MPa, minimum range 0 to 10 kPa)

Measurement
range
30 to 40 kPa
40 to 250 kPa
50 to 1 MPa
Sealing methodWStainless steel welded seals

Electrical
connection
 
-E1Aluminum housing, polyurethane coating, female thread 1/2 NPT cable entry
-E2Aluminum housing, polyurethane coating, female thread M20 x T5 cable entry
-E3SUS316 stainless steel housing, female thread 1/2 NPT cable entry
-E4SUS316 stainless steel housing, female thread M20 x 1.5 cable entry
Output signalS724 V DC loop power supply, 4 to 20 mA, HART 7, two-wire
RModbus RTU, four-wire, 24 V DC loop power supply
Display modeM0Without display
M5LCD with backlight display module, physical buttons and magnetic bar
Connection
location
/HLConnection of high and low pressure end (same parameters for high and low pressure end/L option not selected)
/HHigh voltage terminal connection (optional if the parameters of the high and low voltage terminals do not coincide)
Connection typeCCapillary tapping
Capillary typePPVC sheath and armored SUS304 stainless steel
H-end capillary length00Capillary-free
011 m capillary tube, PVC sheath and armored SUS304 stainless steel 
022 m capillary tube, PVC sheath and armored SUS304 stainless steel 
033 m capillary tube, PVC sheath and armored SUS304 stainless steel 
044 m capillary tube, PVC sheath and armored SUS304 stainless steel 
055 m capillary tube, PVC sheath and armored SUS304 stainless steel 
066 m capillary tube, PVC sheath and armored SUS304 stainless steel 
077 m capillary tube, PVC sheath and armored SUS304 stainless steel 
088 m capillary tube, PVC sheath and armored SUS304 stainless steel 
099 m capillary tube, PVC sheath and armored SUS304 stainless steel 
1010 m capillary tube, PVC sheath and armored SUS304 stainless steel 
Isolated fluidSNormal temperature silicone oil, temperature range -40 to 205°C
HHigh temperature silicone oil, temperature range 0 to 315°C
Process flangeS4SUS304 stainless steel 
S6SUS316 stainless steel 
Isolation diaphragmASUS316L stainless steelmm
CTantalum (SS316 for process connections)
PSUS316 and PTFE coating (range > 50 kPa)
HHastelloy C-276 (SS316 for process connections)
G316L gold plated
Process connectionH30HG/T 20592-2009 DN80 RF, PN10
H31HG/T 20592-2009 DN80 RF, PN16
H32HG/T 20592-2009 DN80 RF, PN40
H33HG/T 20592-2009 DN80 RF, PN64
XOther connection specifications,please consult the factory
Insert tubeD0No Insert tube
D805OD 66 mm, length 50 mm (for DN80 flange)
D810OD 66 mm, length 100 mm (for DN80 flange)
D815OD 66 mm, length 150 mm (for DN80 flange)
Connection location/LLow pressure end connection (if the parameters of the high and low pressure end are the same, /L option not selected, default provided)
Connection typeCCapillary tapping
Capillary typePPVC sheath and armored SUS304 stainless steel
L-end capillary0Capillary-free
11 m capillary tube, PVC sheath and armored SUS304 stainless steel
22 m capillary tube, PVC sheath and armored SUS304 stainless steel
33 m capillary tube, PVC sheath and armored SUS304 stainless steel
44 m capillary tube, PVC sheath and armored SUS304 stainless steel
55 m capillary tube, PVC sheath and armored SUS304 stainless steel
66 m capillary tube, PVC sheath and armored SUS304 stainless steel
77 m capillary tube, PVC sheath and armored SUS304 stainless steel
88 m capillary tube, PVC sheath and armored SUS304 stainless steel
99 m capillary tube, PVC sheath and armored SUS304 stainless steel
1010 m capillary tube, PVC sheath and armored SUS304 stainless steel
Isolation fluidSNormal temperature silicone oil, temperature range -40 to 205°C
HHigh temperature silicone oil, temperature range 0 to 315°C
Process flangeS4SUS304 stainless steel
S6SUS316 stainless steel
Isolation diaphragmASUS316L stainless steel
CTantalum (316 for process connections)
PSUS316 and PTFE coating (range > 50 kPa)
HHastelloy C-276 (316 for process connections)
G316L gold plated
Process connectionH30HG/T 20592-2009 DN80 RF, PN10
H31HG/T 20592-2009 DN80 RF, PN16
H32HG/T 20592-2009 DN80 RF, PN40
H33HG/T 20592-2009 DN80 RF, PN64
XOther connection specifications, please consult the factory
Insert tubeD0No insert tube
D805OD 66 mm, length 50 mm (for DN80 flange)
D810IOD 66 mm, length 100 mm (for DN80 flange)
D815OD 66 mm, length 150 mm (for DN80 flange)
Mounting
bracket
-B01Bend bracket mounted in 2" fixed pipe with install components and fasteners, carbon steel
-B02Bend bracket mounted in backboard with Install components and fasteners,, carbon steel
-B03Flat bracket mounted in 2" fixed pipe with install components and fasteners, carbon steel
-B14Bend bracket mounted in 2" fixed pipe with install components and fasteners, SUS304 stainless steel
-B34Flat bracket mounted in 2" fixed pipe with install components and fasteners, SUS304 stainless steel
Anti-explosiondExdllCT6, NEPSI
iExiallCT4, NEPSI
NAUnavailable
Special
treatment
TDegreasing (removing oil and grease from product surface)
NAUnavailable
Extended
warranty
2W2-year warranty
3W3-year warranty
Flushing ringR80DN80, 316 stainless steel, clamping type
Subsidiary requirementsENEnglish stainless steel nameplate and stainless steel anti-explosion cable gland
Special
certifications
SILSIL
AdATEX Exd
AiATEX Exla
CECertificate of Compliance
IdIEC Exd
liIEC Exia
Alarm outputHHNAMUR NE43 analog output, high alarm, 20.8 mA
LLNAMUR NE43 analog output, low alarm, 3.8 mA
NAUnavailable
 
Packaging & Delivery
CategoryProduct Size International Commercial Terms (Incoterms)Terms of PaymentNearest Port
AT5010 DN80 Dual Falnge Level Transmitter18 cm*18 cm*25 cmCIF, CFR, DAPLC, T/T, D/PShanghai, Guangzhou, Tianjin

Related Products
AT5010 Differenrial Pressure Transmitter
AT5010 Single Flange Level TransmitterAT5020 Pressure Transmitter
AT5020 Single Flange Pressure TransmitterAT4500S Sanitary Pressure Transmitter
Company Profile

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA