AL2000 Magnetic Level Gauge
Guided Wave
0 to 15,000mm
±8mm
Liquid Level Transmitter
Split Type
2 Year/3 Year
304, 316L, PP, PTFE
0 to 420ºC
-0.1 to 16.0 MPa
LCD Display
SS304, SS316L, PP, PTFE
Auminum Alloy or Stainless Steel
HollySys
as Required
China
9026100000
Product Description
Based on the advantages of similar products at home and abroad, and combining with the actual situation in China, AL2000 series magnetic level gauge is a new generation of liquid level measuring instrument, which is produced on the basis of the standard of magnetic level gauge HG/T21584-95 promulgated by the former Ministry of Chemical Industry of The People's Republic of China, and can be used to detect the liquid level (interface) of liquid media in equipment made of various materials. Because the detection part of level gauges in this series is completely isolated from the display part, it has unique advantages in measuring the liquid level of high temperature, high pressure, high viscosity, toxic, harmful and strongly corrosive media, and has better reliability and safety than traditional glass tube and base type level gauges.
Coupled with a level control and alarm switch, the series of level gauges realize level control, alarm, and linkage. Coupled with a built-in integrated level transmitter, it can convert the level (interface) signal into a two-wire 4~20mADC standard signal to achieve long-distance liquid level detection and control. It is widely applied to liquid level measurement and control in the various industries' production processes-electric power, petrochemicals, chemicals, metallurgy, environmental protection, shipping, construction, food, and more.
Features
· High Accuracy: Provides accurate results, avoiding errors and losses caused by inaccurate measurement.
· High Reliability: Demonstrates good stability and reliability, ensuring stable operation in different working environments with minimal occurrence of faults.
· Interference Resistance: Keep normal operation in harsh environments, including those with magnetic fi elds or other electromagnetic interferences, high temperature, high pressure, and corrosive environments.
· Applicability: It can be applied to various measurement objects and application scenarios, catering to the diverse needs of users. It offers HART signal for convenient remote confi guration and troubleshooting, while also featuring an on-site magnetic column display and LCD digital display.
· Durability: It boats a long service life, extended usage without signifi cant wear or damage.
· Easy Maintenance: Easy to maintain and repair in case of faults, reducing users' maintenance costs and time.
· User-Friendly Operation: With its simple interface and intuitive operating methods, it offers users convenience and comfort during operation.
· High Safety: Takes safety into consideration, preventing abnormal situations such as excessively high or low levels, ensuring the safety of the production process. It is armed with liquid level switch alarm function.
· Cost-Effectiveness: It strikes a balance between performance, quality, and price, offering a high cost-performance ratio. Users can expet favorable economic returns while using it.
Structural and Principle
The magnetic level gauge is developed according to the buoyancy principle (Archimedes) combined with the magnetic coupling effect. When the liquid level in the measured container rises and falls, the float in the main pipe of the level gauge also rises and falls, and the permanent magnetic steel in the float is transmitted to the fi eld indicator (ruler) through the magnetic coupling effect to turn the red and white turning columns. When the liquid level rises, the turning column is turned from white to red. When the liquid level drops, the turning column turns from red to white. The red-white junction of the indicator is the actual height of the medium level in the container
Product Images






Technical Specification
During model selection, firstly select the series models according to the main technical parameters listed in the Model and Specifi cation Table (I), and then select the supporting devices and accessories according to the Model and Specifi cation Table (II). The design temperature and design pressure listed in the Model and Specifi cation Table (I) are standard. If the user's working condition requirements are higher than these technical parameters, please indicate the requirements when ordering.
Model and Specification Table (I)
Model and Specifi cation Table (II)
Schematic Diagram of Installation

Packaging & Delivery
Company Profile



Coupled with a level control and alarm switch, the series of level gauges realize level control, alarm, and linkage. Coupled with a built-in integrated level transmitter, it can convert the level (interface) signal into a two-wire 4~20mADC standard signal to achieve long-distance liquid level detection and control. It is widely applied to liquid level measurement and control in the various industries' production processes-electric power, petrochemicals, chemicals, metallurgy, environmental protection, shipping, construction, food, and more.
Features
· High Accuracy: Provides accurate results, avoiding errors and losses caused by inaccurate measurement.
· High Reliability: Demonstrates good stability and reliability, ensuring stable operation in different working environments with minimal occurrence of faults.
· Interference Resistance: Keep normal operation in harsh environments, including those with magnetic fi elds or other electromagnetic interferences, high temperature, high pressure, and corrosive environments.
· Applicability: It can be applied to various measurement objects and application scenarios, catering to the diverse needs of users. It offers HART signal for convenient remote confi guration and troubleshooting, while also featuring an on-site magnetic column display and LCD digital display.
· Durability: It boats a long service life, extended usage without signifi cant wear or damage.
· Easy Maintenance: Easy to maintain and repair in case of faults, reducing users' maintenance costs and time.
· User-Friendly Operation: With its simple interface and intuitive operating methods, it offers users convenience and comfort during operation.
· High Safety: Takes safety into consideration, preventing abnormal situations such as excessively high or low levels, ensuring the safety of the production process. It is armed with liquid level switch alarm function.
· Cost-Effectiveness: It strikes a balance between performance, quality, and price, offering a high cost-performance ratio. Users can expet favorable economic returns while using it.
Structural and Principle
The magnetic level gauge is developed according to the buoyancy principle (Archimedes) combined with the magnetic coupling effect. When the liquid level in the measured container rises and falls, the float in the main pipe of the level gauge also rises and falls, and the permanent magnetic steel in the float is transmitted to the fi eld indicator (ruler) through the magnetic coupling effect to turn the red and white turning columns. When the liquid level rises, the turning column is turned from white to red. When the liquid level drops, the turning column turns from red to white. The red-white junction of the indicator is the actual height of the medium level in the container
Product Images







Technical Specification
During model selection, firstly select the series models according to the main technical parameters listed in the Model and Specifi cation Table (I), and then select the supporting devices and accessories according to the Model and Specifi cation Table (II). The design temperature and design pressure listed in the Model and Specifi cation Table (I) are standard. If the user's working condition requirements are higher than these technical parameters, please indicate the requirements when ordering.
Model and Specification Table (I)
Installation form | Series model | Structural features | Wetted part material | Measurement range | Design temperature | Design pressure |
Side- mounted | AL2001 | Basic type | 304, 316L | 0-300 ~ 15000mm | 0 ~ 150ºC | -0.1 ~4.0MPa |
AL2002 | Medium-temperature and medium-pressure type | 304, 316L | 0-300 ~ 6000mm | 0 ~200ºC | 4.0 ~6.3MPa | |
AL2003 | High-temperature and high- pressure type | 304, 316L | 0-300 ~ 6000mm | 0~420ºC | 6.4 ~16.0MPa | |
AL2004 | Sanitary type | 316L | 0-300 ~ 6000mm | 0~150ºC | -0.1 ~2.5MPa | |
AL2005 | Low-density type | 304, 316L | 0-300 ~ 6000mm | -15~100ºC | -0.1 ~6.3MPa | |
AL2006 | PP corrosion-proof type (304 lined PP) | PP | 0-300 ~ 6000mm | 0~80ºC | 0 ~0.6MPa | |
AL2007A | PTFE corrosion-proof type (304 lined PTFE) | PTFE | 0-500 ~ 6000mm | 0~150ºC | 0 ~2.5MPa | |
AL2007B | -0.1 ~0MPa, 0 ~10MPa | |||||
AL2008A | Jacket heating type | 304, 316L | 0-300 ~ 6000mm | 0~200ºC | -0.1 ~4.0MPa | |
AL2008B | Electric heat tracing type | 304, 316L | 0-300 ~ 6000mm | 0~100ºC | -0.1 ~4.0MPa | |
AL2009 | Vacuum jacket type | 304, 316L | 0-300 ~ 6000mm | -15~200ºC | -0.1 ~6.3MPa | |
AL2010 | Balanced transmission type | 304, 316L | 0-300 ~ 15000mm | 0~200ºC | 0MPa | |
AL2011 | PP type | PP | 0-300 ~ 3000mm | 0~80ºC | 0 ~0.6MPa | |
AL2012 | Low-temperature and frost- proof type | 304, 316L | 0-300 ~ 6000mm | -60~0ºC | -0.1 ~6.3MPa | |
Top- mounted | AL2020 | Ordinary top-mounted type | 304, 316L | 0-500 ~ 4000mm | -15~420ºC | -0.1 ~2.5MPa |
AL2021 | Top-mounted type without protective tube | 304, 316L | 0-800 ~ 4000mm | -15~420ºC | -0.1 ~4.0MPa | |
AL2022 | PP corrosion-proof and top- mounted type | PP | 0-800 ~ 4000mm | 0~80ºC | 0 ~0.6MPa | |
AL2023A | PTFE corrosion-proof and top- mounted type | PTFE | 0-800 ~ 3500mm | 0~150ºC | 0 ~1.6MPa | |
AL2023B | -0.1 ~0MPa, 0 ~1.6MPa | |||||
Side- mounted | AL2500 | Magnetic sensitive type | 304, 316L | 0-300 ~ 10000mm | 0~200ºC | -0.1 ~16.0MPa |
Model and Specifi cation Table (II)
AL20** | Magnetic Level Gauge | Serial No. | ||||||||||||
P0 | Not provided with blowdown valve | Drain valve | ||||||||||||
P1 | Provided with blowdown valve (ball valve) | |||||||||||||
P2 | Provided with blowdown valve (stop valve) | |||||||||||||
P3 | Provided with blowdown valve (special for polypropylene ball valve AL2006/2011) | |||||||||||||
P4 | Provided with blowdown valve (fluorine-lined diaphragm ball valve) | |||||||||||||
M0 | Not provided with 4~20-m ADC remote transmitter | Transmitter If HART protocol is required, add the suffi x H (e.g. M1H, M2H, M3H, M4H) | ||||||||||||
M1 | Provided with waterproof 4 - 20mADC remote transmitter | |||||||||||||
M2 | Provided with intrinsically safe 4 - 20mADC remote transmitter | |||||||||||||
M3 | Provided with explosion-proof 4 - 20mADC remote transmitter | |||||||||||||
M4 | Provided with YC200 magnetostrictive level transmitter with output of 4~20mADC | |||||||||||||
K0 | Not provided with the level switch | Optional level switch YK01 for linkage YK02 for alarm | ||||||||||||
K1 | Provided with YK01 regional level switch. If the level gauge needs to be equipped with 2 YK01 switches, the selecting type shall be 2K1 | |||||||||||||
K1B | Provided with YK01 regional level switch (Exd), with the same selecting type as above | |||||||||||||
K2 | Provided with YK02 reed memory type level switch, with the same selecting type as above | |||||||||||||
K2B | Provided with YK02 reed memory type level switch (Exd), with the same selecting type as above | |||||||||||||
X0 Without LCD | Without LCD | LCD | ||||||||||||
X1 With LCD | With LCD | |||||||||||||
F1 | Wetted part material: stainless steel 304 | Wetted part material | ||||||||||||
F2 | Wetted part material: stainless steel 316L | |||||||||||||
F3 | Wetted part material: pp/pvc | |||||||||||||
F4 | Wetted part material: 304 + PTFE | |||||||||||||
F5 | Others | |||||||||||||
L | Panel material: aluminum alloy | Panel material | ||||||||||||
S | Panel material: stainless steel | |||||||||||||
- | Flange specifi cation (nominal diameter, nominal pressure and sealing surface | Flange specification | ||||||||||||
- | Measurement range (mm) | Processing parameter | ||||||||||||
- | Installation height (mm) (Note: side-mounted level gauge does not include this item) | |||||||||||||
C | Atmospheric pressure vessel | |||||||||||||
- | Actual operating pressure (MPa) | |||||||||||||
- | Medium density g/cm3 | |||||||||||||
L | Liquid level (can be omitted) | Measurement method | ||||||||||||
J | Interface level |
Schematic Diagram of Installation

1. Side-mounted magnetic level gauge | 2. Top-mounted level gauge without protective tube | 3. Top-mounted level gauge with protective tube | 4. Balanced transmission type level gauge |
AL2001 ~ 2012 side-mounted level gauge is suitable for the medium under the status of room temperature, atmospheric pressure, high temperature, high pressure, low temperature, and high viscosity, low density and strong corrosiveness. | AL2021 top-mounted level gauge without protective tube is suitable for liquid level measurement of heavy oil, crude oil, resin and other high viscosity medium. AL2023 top-mounted corrosion-proof level gauge is suitable for liquid level measurement of low-level hydrochloric acid tank and other liquid levels. | AL2020/2022 top-mounted level gauge with protective tube is suitable for liquid level measurement of underground storage tanks, such as buried oil tanks and low-level acid tanks. | AL2010 balanced transmission type level gauge is specially designed for storage tanks with high viscosity medium and large measurement range. Typical examples include heavy oil storage tanks and oil storage tanks. |
This type of level gauge is equipped with built-in remote transmitter and YK01 and YK02 level switches to realize remote measurement or control alarm of liquid level. |
Packaging & Delivery
Category | International Commercial Terms (Incoterms) | Terms of Payment | Nearest Port |
AL2000 Magnetic Level Gauge | CIF, CFR, DAP | LC, T/T, D/P | Shanghai, Guangzhou, Tianjin |