Honle Zw32 Outdoor High Voltage Vacuum Circuit Breaker Vcb 1250A

Price $1600.00 Compare
Min Order 10 Pieces
Shipping From Zhejiang, China
Popularity 461 people viewed
Quantity
+-
 

Honle Group Co., Ltd.

VIP   Audited Supplier 12 years
Profile Certified by SGS/BV
ZW32
High Voltage Circuit Breakers
Electric Type
Normal Type Circuit Breaker
Vacuum
Fixed
Vcb
3
Circuit Breaker
Conventional Circuit Breaker
12kv, 24kv, or 40.5kv
50Hz
630A, 1250A, 2000A, 2500A, or 3150A
20ka
50ka
20ka
50ka
Honle
Standard Export Package
630A-1250A
Zhejiang, China
Product Description
 
Description:

ZW32-12,24,40.5 outdoor vacuum circuit breaker (hereinafter referred to as circuit breaker) is an outdoor power distribution equipment with rated voltage of 12KV,24KV or 40.5KV and three-phase AC 50Hz. It is mainly used to break and close the load current, overload current and short circuit current in the power system. It is suitable for protection and control in substation and industrial and mining enterprise substation systems, and places where rural power grids operate frequently.

The circuit breaker has the characteristics of small size, light weight, anti-condensation and maintenance-free, and can adapt to harsh weather conditions and dirty environments.



Standards compliant:

GB1984 "AC high voltage circuit breaker"
GB11022 "Common technical requirements for high-voltage switchgear and control equipment standards"
GB311.1-6 "Insulation coordination of high voltage power transmission and transformation equipment"
GB763 "Communication of AC high voltage electrical appliances during long-term work"
BG2706 "Test Method for Dynamic and Thermal Stability of AC High Voltage Apparatus"
GB3309 "Mechanical test of high voltage switchgear at room temperature"
DL/T593 "Technical Conditions for Common Ordering of High Voltage Switchgear"


 

Sr.

Name

Unit

Value

1

Rated voltage

KV

12,24,40.5

2

Rated frequency

Hz

50

3

Rated current

A

630,1250,2000,2500,3150

4

Rated short-circuit breaking current

KA

20

5

Rated peak withstand current (peak)

KA

50

6

Rated short-time withstand current

KA

20

7

Rated short circuit closing current (peak)

KA

50

8

Mechanical life

Time

10000

9

Rated short circuit current breaking times

Time

30

10

Power frequency withstand voltage (1min): (wet) (dry) phase, ground, fracture

KV

42/48

11

Lightning impulse withstand voltage (peak), phase to ground, fracture

KV

75/85

12

Secondary circuit 1min power frequency withstand voltage

KV

2