DR-200
Digital X-ray
20kw
500GB
Shinova
Carton
China
9018909919
Product Description
200mA Veterinary Digital X-ray Machine
Model: DR-200
Feature:
Soft touch user panel
Digital displays of kV, mAs and time
High frequency inverter type generator
Overload protection for kV, mA, Time and Temp
Self-manageable APR function with memory keys
Specification:
Range of tube current: 16~200mA
Inverter frequency: ≥30kHz
Tube voltage range of radiography: 40kv~125kv
Range of exposure time: 0.0025s~6.4s
mAs range: 0.5mAs~320mAs
Input voltage range: AC 220V±22V
Communication interface: RS-232
Other: Capacity lock automatically, fault diagnosis automatically, self-protection
Focus: Small focus:1.0mm Large focus:2.0mm
Anode input power: Small focus:20KW Large focus:40KW
Anode speed: 2800 R/M
Target angle: 17.5°
Anode heat content: 100kJ(140kHU)
Bearing weight: 150kg
Table movement: With wheels
Tabletop movements: Four ways
Tabletop position: By soundless manual brakes
Size: 18"×18"
Grid ratio: 10:1
Grid density: 40L/cm
Focusing distance: 1500mm
Material: CSI
Scanning Area: 17*17 inch
A/D Conversion: 16 Bit
Total Pixel matrix: 3328(h)*3328(v) (11million pixels)
Pixel Size: 127μm
Image Preview Time: Not more than 2s
Memory: 4GB
Disk Capacity: 500GB
Medical LCD: 19″ LCD
Function: Image acquisition, image zoom, image brightness adjustment, image contrast adjustment, image rotation, image rollovers
Connection: 100M network interface, Dicom 3.0 image transmission, and query, editing & print, etc.
Management: DR system to manage animals and image information
Configuration:
200mA HF generator and Console
Collimator
X-ray tube (Toshiba 7239 is optional)
Veterinary radiography table
Grid (JPI in Korea)
Flat panel detector (Rayence in Korea)
Imaging workstation computer and LCD monitor







Model: DR-200
Feature:
Soft touch user panel
Digital displays of kV, mAs and time
High frequency inverter type generator
Overload protection for kV, mA, Time and Temp
Self-manageable APR function with memory keys
Specification:
- HF Generator
Range of tube current: 16~200mA
Inverter frequency: ≥30kHz
Tube voltage range of radiography: 40kv~125kv
Range of exposure time: 0.0025s~6.4s
mAs range: 0.5mAs~320mAs
Input voltage range: AC 220V±22V
Communication interface: RS-232
Other: Capacity lock automatically, fault diagnosis automatically, self-protection
- X-ray Tube
Focus: Small focus:1.0mm Large focus:2.0mm
Anode input power: Small focus:20KW Large focus:40KW
Anode speed: 2800 R/M
Target angle: 17.5°
Anode heat content: 100kJ(140kHU)
- Veterinary Radiography Table
Bearing weight: 150kg
Table movement: With wheels
Tabletop movements: Four ways
Tabletop position: By soundless manual brakes
- Grid
Size: 18"×18"
Grid ratio: 10:1
Grid density: 40L/cm
Focusing distance: 1500mm
- Flat Panel Detector
Material: CSI
Scanning Area: 17*17 inch
A/D Conversion: 16 Bit
Total Pixel matrix: 3328(h)*3328(v) (11million pixels)
Pixel Size: 127μm
Image Preview Time: Not more than 2s
- Imaging Workstation Computer and LCD monitor
Memory: 4GB
Disk Capacity: 500GB
Medical LCD: 19″ LCD
Function: Image acquisition, image zoom, image brightness adjustment, image contrast adjustment, image rotation, image rollovers
Connection: 100M network interface, Dicom 3.0 image transmission, and query, editing & print, etc.
Management: DR system to manage animals and image information
Configuration:
200mA HF generator and Console
Collimator
X-ray tube (Toshiba 7239 is optional)
Veterinary radiography table
Grid (JPI in Korea)
Flat panel detector (Rayence in Korea)
Imaging workstation computer and LCD monitor