Hospital Medical Intelligent 0.5t Superconducting MRI Scan Magnetic Resonance Imaging System Equipment

Price $310000.00 Compare
Min Order 1 Piece
Shipping From Chongqing, China
Popularity 309 people viewed
Quantity
+-
 

Chongqing Vision Star Optical Co., Ltd.

VIP   Audited Supplier 11 years
Profile Certified by SGS/BV
XMR050A
Imaging Diagnostic Equipment
X Ray Equipment
CE, ISO13485
Basda
Yes
Windows 7
≥3.0GHz
≥2.0GB
24″LCD TFT
Standard
1500fps
≥500GB
≥2,650,000
DVD
Yes
Yes
Multi-Parameter
Pressure, Temp, Liquid Level
Visionstar
Wooden
China
Product Description
Hospital Medical Intelligent 0.5T Superconducting MRI Scan Magnetic Resonance Imaging System Equipment


Feature:

* 0.5T Open MRI is trustworthy because  the system combines with both superconductive magnetic resonance system's advantage of fast scanning speed same advantage of patient comfort and low operating cost as permanent magnet MRI.

* 0.5T open type is more competitive compared to 1.5T superconductive MRI.  

* Its electricity cost is much lower than conventional 1.5T MRI systems.

* It config 4k cold head from Japan, the brand is Sumitomo, that provides "zero" consumption of the liquid helium.

* It is very suitable for interventional treatment, this is different with all the traditional 1.5T MRI in the market, thus the hospital can bring more new clinical projects and get the additional benefits.

* It has faster scanning time than permanent MRI, and the image quality is also better than permanent MRI, being close to 1.5T superconductive MRI level.

* Its open type superconducting magnet, has a large opened space that helps to reduce the patient's claustrophobic fear, effectively avoid the involuntary movement which may cause the image artifacts and other potential risk.

Rich Coil Configuration

The Receiver coil, together with parallel acquisition technology, improve the signal-to-noise ratio and image quality. The customer can choose according to the clinical needs (specific configuration of the coil number and types will be subject to final contract): head coil, neck coil, body coil(s), body coil(soft), knee coil, breast coil, body coil(L), shoulder coil, ankle coil, wrist coil.

Gradient Sub System

* Gradient sub system directly determine the spatial encoding of MRI system, it produces the signal information, at the same time it can perform GR series sequence scanning, it is the foundation of MRI system's spatial resolution ability, gradient sub system also directly affect the scanning image thin slice scanning.The linearity of gradient system of MRI system determine the accuracy of spatial location information, ensuring that in any acquisition, the image distortion is limited.

* Gradient switching rate is an important factor of MRI scanning speed. XMR050A using the self-shielding gradient coil and high duty cycle gradient amplifier system, together with eddy zero technology and design, not only can avoid the eddy current between the metal shielding layers, but also can concentrate the eddy current from X axis and Y axis to Z axis, then by software algorithm, eliminate all eddy current. This technology can raise up the spatial encoding ability of the magnetic resonance signal and make the scan more precise, ensure high resolution image quality.

* When gradient system working its current is high, and switching rate is high as well, thus the noise emitted by MRI system is easy to make the patient discomfort, XMR050A using special hardware noise reduction design technology, the original gradient noise is reduced up to 66%, and XMR050A provides a friendlier scanning environment for the patients.

* The gradient system using air cooling to save maintenance cost for the user.

RF Sub System

* The RF sub system is the source of MRI proton excitation energy, its efficiency directly affects the MRI relax signal. RF receiver receive MRI relax signal, a good receiving coil can improve the SNR of image.

* The RF sub system is similar as highway lane, the more lanes, the faster flow of vehicles. Vice versa, the more the RF system channels, the faster parallel acquisition, thus the system can process the greater the amount of data in the same time, reduce the imaging time. XMR050A suing 4 channel radio frequency receiving, combined with the latest parallel sampling technology, using the DDC digital direct sampling, can short the scan time and get excellent image quality.

No.ItemSpecification
1Magnet System
1.1Magnet typeSuperconductive,open type
1.2Field strength0.5T
1.3Magnet shapeDual post
1.4Homogeneity (DSV,VRMS)≤2.5ppm
1.5Magnet stability≤1ppm/h
1.6Shimming method and typePassive/active/dynamic
1.7Total capacity of liquid helium(100%liquid helium full filled)≤100L
1.8Liquid helium"zero"consumption technologyYes
1.9Cold head

Sumitomo from Japan,Air

cooling helium compressor

1.1Magnet gap420mm
1.11Magnet open rate280°
1.125 Gauss fringe field(X,Y,Z axis)≤4.5m,4.5m,4.5m
2Gradient System
2.1Maximum gradient field (single axis,invalid)25mT/m
2.2Maximum gradient slew rate(single axis, invalid)96mT/m/ms
2.3Minimum gradient rise time≤0.26ms
2.4Gradient cooling systemAir cooling
3RF System
3.1Spectrum meterFull digital
3.2RF channel typeFull digital transmit and receive
3.3RF channels4
3.4Max RF amplifier power≥5kW
3.5Receiver bandwidth1.25MHz
3.6Receiver coilMulti-channel phased array
3.7Head coilAvailable to config
3.8Neck coilAvailable to config
3.9Body coil (Small)Available to config
3.1Body coil (Soft)Available to config
3.11Knee coilAvailable to config
3.12Ankle coilAvailable to config
3.13Shoulder coilAvailable to config
3.14Body coil (Large)Available to config
3.15Breast coilAvailable to config
3.16Joint analysis coilAvailable to config
3.17Wrist coilAvailable to config
 Remark:The coil configuration is subject to the final contract 
4Scan environment
4.1Patient tableYes
4.2Maximum patient weight200kg
4.3LocalizerYes
4.4Position accuracy1mm
4.5Table control system on both side of rackYes
4.6Position accessoriesYes
4.7ICE stop keyYes
4.8Calling systemYes
5Computer system
5.1MRI softwareBASDA
5.2IPCYes
5.3OSWindows 7
5.4CPU≥3.0GHz
5.5RAM≥2.0GB
5.6Monitor24″LCD TFT
5.7Mouse and keyboardStandard
5.8Image reconstruction speed(256x 256)1500FPS
5.9HDD≥500GB
5.1HDD storage(256×256)≥2,650,000
5.11Storage typeDVD
5.12DICOM 3.0Yes
5.13EthemetYes
5.14System monitorMulti-parameter
5.15Monitor parameterPressure, temp, liquid level
6Scanning parameter
6.1Max,FOV450mm
6.2Min.FOV50mm
6.3Min.2D slice thickness1.0mm
6.4Min.3D slice thickness0.1mm
6.5Max.imaging matrix1024×1024
7Sequence and technology
7.1Spin-echo sequenceYes
7.1.1FSEYes
7.1.2FSE sharing technologyYes
7.2IR sequenceYes
7.2.1FIRYes
7.2.2FLAIRYes
7.2.3T1-FLAIRYes
7.2.4Water-fat SeparationYes
7.2.5STIRYes
7.3MRA(2D/3D TOF)Yes
7.3.1MRCPYes
7.3.2MRURYes
7.3.3MRMYes
7.3.4Ultra-fast water imaging technologyYes
7.4GRE 2D/3DYes
7.4.1Fast GREYes
7.5DWIYes
7.5.1Max.b value(s/mm2)1000
7.6Section scanning technologyYes
7.7Pre-saturationYes
7.8Pre-saturation field adjustmentYes
7.9MIPYes
7.1MinIPYes
7.113D ReconstructionYes
7.12Anti-movement scanning technologyYes
7.13Metal implant imagingYes
7.14Online filterYes
7.15Online post processingYes
7.163D scoutYes
7.17Scanning parameter presetYes
7.18Queue scanning technologyYes
7.19RF de-phase technologyYes
7.2lmage fusion technologyYes
7.21Eddy current adaptive correctionYes
7.22Gradient linearity correctionYes
7.23Multi-echo phase correctionYes
7.24Rapid automatic correction technologyYes
7.25Automatic frequency tracking technologyYes
7.26Automatic coil recognition technologyYes
7.27Echo navigation technologyYes
7.28RF balance drive technologyYes
7.29Gradient de-phase technologyYes
7.3Respiratory compensationYes
7.31Elimination of magnetic sensitive artifactYes