Essential Details
Name:Biological Indicator Evaluation Resistometer(BIER) | Brand: AIKSMED |
Model: KLY Series | Application:Biological Indicator, Chemical Indicator, Autoclave Tape |
Chamber Volume: 3L, 5L | Door type: Single Door |
Design Pressure: 0.4 MPa | |
Working Pressure: -0.1~0.35 MPa | Working Temperature: 110~145ºC |
Original: China | Warranty: 1 year |
Quantity(sets) | 1 - 1 | 2 - 5 | 6 - 10 | >10 |
Lead time (days) | 60 | 65 | 75 | To be negotiated |

Features:
---PLC control, automatic and reliable.
---10″ touch screen(HMI)displays technical process and parameters, easy to operate.
---Parameters can be set and stored.
---Equipped with PC and printer, access to remote monitoring and data record.
---Built-in steam generator, no need external steam supply.
---Safety valve to avoid over-pressure.
---Water shortage protection function.
---Door pressure safety interlock mechanism.
---Diverse preset cycles, able to customize cycles according to requirements.
Model | Volume (L) | Chamber (Φ*Dmm) | Overall (L*W*Hmm) | |
Hinged Door | KLY-3 | 3 | 125*250 | 900*700*1700 |
KLY-5 | 5 | 150*250 | 900*700*1700 |
AIKSMED is an expert manufacturer of diversed sterilizers and autoclaves, ranging from Cassette Autoclaves for dental &
ophthalmology clinics, Laboratory Steam Sterilizers for research organizations, Saturated Steam Sterilizers for garments and
tools, and Superheated Water Cascade Sterilizers for liquid injections in pharmaceutical industries.
1.What is FAT and SAT?
FAT means Factory Acceptance Test, before delivering autoclaves, customer can send his technician or 3rd party personel to test machines in AIKSMED facotry, it usually takes 2~3 days. SAT means Site Acceptance Test, AIKSMED will send 1~2 engineers to user's site for equipment commissioning and staff training, ensuring production able to be carried out successfully.
2. Is it possible for our autoclave and sterilizers idle for years to restart?
3. Regarding ampoule injection, How to choose between steam sterilizer and superheat water autoclave
Firstly these two kinds of autoclave sterilization machines got their own advantages on heating-up speed and cooling, uniform thermal distribution, and etc. But It mainly depends on the loads packing material and size, if glass ampoule, and size is 1ml, 2ml, 5ml, 10ml, we recommend steam sterilization with advantage of fast heating-up and less cost on utility consumption. However, if the container size over 10ml, then superheated water cascade sterilizer is more appropriate to reduce the broken rate after sterilizing, with advantage of regular heating-up, but it costs more on utility consumption and budget. Customer needs to consider based on own situations and long term operation.