Hot Sale Astmb399 6201 Aluminium Alloy Conductor AAAC Greeley 795mcm

Price $2.10 Compare
Min Order 100 Meters
Shipping From Shanghai, China
Popularity 464 people viewed
Quantity
+-
 

Shanghai QIFAN Cable Co., Ltd.

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
AAAC
Bare
Stranded
Overhead
Alloy
Bare
Bare
Round Wire
Transmission Power Line
ISO9001, CCC, RoHS
QIFAN
Silver
10 Years
200
qifan
Reel and Drum
1/0 2/0 4/0
China
761490000
Product Description
 
Transmission Use overhead aluminium cable AAAC Conductor for Overhead Use


Application:

Used as bare overhead conductor for primary and secondary distribution. Designed for utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics.
(1)AAAC conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coastlines where there can be a problem of corrosion in the steel of an ACSR construction.
(2)The aluminum alloy conductors are used in replace of single-layer ACSR conductors to reduce power loss in overhead distribution and transmission lines,when replacing the aluminum conductor steel reinforced , the AAAC can save 5-8% of the construction cost.
(3)AAAC referred to have higher strength but lower conductivity than pure aluminum. Being lighter, alloy conductors can sometimes be used to replace the conventional ACSR.

 

IEC Standard AAAC Condcutor Parameter Date

Code numberAreaNumber of wiresDiameterLinear massRated strengthD.C resistance
mm2Wire(mm)Cond(mm)kg/kmkNOhm/km
1618.671.845.5250.86.041.7896
252972.36.979.59.441.1453
4046.572.918.72127.115.10.7158
6373.273.6510.9200.223.060.4545
100116192.7914319.337.760.2877
125145193.1215.6399.247.20.2302
160186193.5317.651158.560.1798
200232193.9519.7638.773.20.1439
250290194.4122.1798.491.50.1151
315366373.5524.81008.4115.290.0916
400465374281280.5146.40.0721
450523374.2429.71440.5164.70.0641
500581374.4731.31600.61830.0577
560651613.6933.21795.3204.960.0516

BS Standard AAAC Condcutor Parameter Date

Code NameAreaNo.of wiresDiameterMass per unit lengthRated strengthDC resistance
mm2Wire(mm)Cond(mm)kg/kmkNΩ/km
BOX18.871.855.5551.45.551.748
ACACLA23.872.086.2464.97.021.3828
ALMOND30.172.347.0282.28.881.0926
CEDAR35.572.547.6296.810.460.9273
DEODAR42.272.778.31115.212.440.7797
FIR47.872.958.85130.614.110.6875
HAZEL59.973.39.9163.417.660.5494
PLNE71.673.6110.8195.621.140.4591
HOLLY84.173.9111.7229.524.790.3913
WILLOW89.774.0412.124526.470.3665
OAK118.974.6514324.535.070.2767
MULBERRY150.9193.1815.9414.344.520.2192
ASH180.7193.4817.4496.153.310.183
ELM211193.7618.8579.262.240.1568
POPLAR239.4372.8720.1659.470.610.1387

 
 


 