NMD90
Insulated
Stranded
Heating
Copper
PVC
PVC
Flat Wire
ISO9001, CE, CCC, RoHS, VDE
600V
cUL CSA
Roll/Drum
Building Wire
HT CABLES
Coils and Drums
14AWG, 12AWG, 10AWG, 8AWG, 6AWG
China
8544492100
Product Description
14/2 12/2 12-2 14-2 nmd90 w/g Electric coper wire and cable 15ft 25ft 50ft 100ft 250ft 100' 250' roll with Ground
Applications:
NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations.
The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C for two-conductor cables and -10°C for three-conductor cables (with suitable handling procedures). Material should be properly stored above 0°C for 24 hours prior to installation. The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code1 for further
information related to applications.
Codes / Standards
NMD90 cables meet or exceed the following requirements:
CONSTRUCTION
Canada standard C22.2 No. 48 (non-metallic sheathed cable)
Canadian Electrical Code1
NMD90 cables are available as two- or three-conductor cables with a bare grounding conductor. It is
manufactured using annealed (soft) copper conductors-compressed standing for stranded conductors; a
heat-resistant thermoplastic polyvinyl chloride (PVC) insulation and nylon jacket for the individual conductors with a PVC jacket for the overall construction.
Conductors are white, black and red (for 3 conductor cables). Cable jackets are colour coded by size for quick identification in the Table below

JACKET COLOUR CODE - Typical Application Guide
•WHITE - General Residential Wiring
•RED - 2 Black and Red conductors - 208V-240V Circuits (no neutral)
•ORANGE - No. 10 AWG General Residential Wiring
•YELLOW - No. 12 AWG General Residential Wiring
•BLUE - No. 14 AWG - 2 black and white conductors - 120V Arc Fault Circuit Interupter Applications
CABLE PRINTING
12 AWG 2 CDRS BLACK/WHITE NMD90 NYLON 300 VOLTS FT1
NMD90 jackets which reduces the coefficient of friction, allowing cables to be installed without external
lubricants, resulting in reduced labour and materials costs.
PVC / NYLON INSULATION
PVC JACKET
GROUND CONDUCTOR COPPER CONDUCTOR PVC / NYLON INSULATION
PVC JACKET
Specification:
Size | Number of Conductors | Bonding Wire Size (Copper) | Insulation Thickness | Nylon Thicknes | Jacket Thickness | Approximate Overall Dimensions | Approximate Net Cable Weight | Ampacity 30°C Ambient |
AWG | AWG | mm | mm | mm | mm | kg/km | A | |
14 | 2 | 14 | 0.76 | 0.1 | 0.76 | 4.9 x 9.9 | 99 | 15 |
12 | 2 | 14 | 0.76 | 0.1 | 0.76 | 5.3 x 10.7 | 127 | 20 |
10 | 2 | 12 | 0.76 | 0.1 | 0.76 | 5.9 x 12.2 | 181 | 30 |
(diameter) | ||||||||
14 | 3 | 14 | 0.76 | 0.1 | 0.76 | 8.8 | 126 | 15 |
12 | 3 | 14 | 0.76 | 0.1 | 0.76 | 9.7 | 166 | 20 |
10 | 3 | 12 | 0.76 | 0.1 | 0.76 | 10.9 | 239 | 30 |
8 | 3 | 10 | 0.89 | 0.12 | 1.14 | 14.1 | 391 | 45 |
6 | 3 | 8 | 1.14 | 0.15 | 1.14 | 17.2 | 601 | 65 |
4 | 3 | 8 | 1.14 | 0.15 | 1.52 | 20.3 | 876 | 85 |
3 | 3 | 6 | 1.14 | 0.15 | 2.03 | 22.8 | 1136 | 105 |
2 | 3 | 6 | 1.14 | 0.15 | 2.03 | 24.4 | 1355 | 120 |
NMD90 Packing picture