HSP-150-12
Single
3 Years
150W
AC85~264
Series Switching Power Supply
Self-excited Switching Power Supply
Terminal Power Distribution Equipment
One-way Transmission
RoHS, ISO, CCC, TUV
Dhecn
DHECN
30PCS/CTN
ROHS, UL, CE, IEC, ISO9001
China
85044019
Product Description
Features:
· Universal AC input / Full range
· Built-in active PFC function, PF>0.93
· 100% full load burn-in test
· Protections: Short circuit / Over load / Over voltage / Over temp.
· Built-in constant current limiting circuit
· LED indicator for power on
· Remote ON-OFF control(optional)
· Fixed switching frequency at PFC: 67KHz, PWM: 134KHz
· 3 years warranty
· Dimension: 199*99*50mm (L*W*H)
Specification:
1) INPUT
· Voltage Range: 85-264VAC, 120-370VDC; 47-63Hz
· Power Factor: PF>0.93/230VAC PF>0.98/115VAC at full load
· AC Current: 2.5A/115VAC 1.2A/230VAC
· Inrush Current: Cold start 40A/230VAC
· Leakage Current: <2mA/240VAC
2) PROTECTION
· Over Load: 105%-150%; Constant current limiting, recovers automatically after fault condition is removed.
· Over Voltage: 115%-135%; Shut down o/p voltage, re-power on to recover.
· Over temp.: TSW1(Power transistor) Temp. At 95± 5º C, shutdown o/p voltage; Temp. <95± 5º C, O/I auto-recovery.
· Remote control(option): CN1: 4-10VDC POWER ON, <0-0.8VDC POWER OFF
3) ENVIRONMENT
· Working Temp. & Humidity: -10º C~+60º C; 20%~90% RH.
· Storage Temp. & Humidity: -20º C~+85º C; 10%~95% RH.
· Vibration: 10~500Hz, 2G 10min. /1 cycle, period for 60min, each along X, Y, Z axes.
4) SAFETY STANDARDS
· Withstand Voltage; I/P-O/P: 3KVAC; I/P-FG: 1.5KVAC; O/P-FG: 0.5KVAC
· Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG: 100MΩ /500VDC
· Safety Standards: Design refer to UL1950, TUV, EN60950
· EMC Standards: Design refer to EN55022, EN61000-3-2, -3, EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, EN55024
5) Type No Output Tol. R&N Effi.
HSP-150-3.3 3.3V, 30A ± 2% 100mV 67%
HSP-150-5 5V, 30A ± 2% 100mV 75%
HSP-150-7.5 7.5V, 20A ± 2% 100mV 79%
HSP-150-12 12V, 12.5A ± 2% 100mV 80%
HSP-150-13.5 13.5V, 11.2A ± 2% 100mV 80%
HSP-150-15 15V, 10A ± 2% 100mV 81%
HSP-150-24 24V, 6.3A ± 1% 150mV 83%
HSP-150-27 27V, 5.6A ± 1% 150mV 84%
HSP-150-48 48V, 3.2A ± 1% 250mV 84%




· Universal AC input / Full range
· Built-in active PFC function, PF>0.93
· 100% full load burn-in test
· Protections: Short circuit / Over load / Over voltage / Over temp.
· Built-in constant current limiting circuit
· LED indicator for power on
· Remote ON-OFF control(optional)
· Fixed switching frequency at PFC: 67KHz, PWM: 134KHz
· 3 years warranty
· Dimension: 199*99*50mm (L*W*H)
Specification:
1) INPUT
· Voltage Range: 85-264VAC, 120-370VDC; 47-63Hz
· Power Factor: PF>0.93/230VAC PF>0.98/115VAC at full load
· AC Current: 2.5A/115VAC 1.2A/230VAC
· Inrush Current: Cold start 40A/230VAC
· Leakage Current: <2mA/240VAC
2) PROTECTION
· Over Load: 105%-150%; Constant current limiting, recovers automatically after fault condition is removed.
· Over Voltage: 115%-135%; Shut down o/p voltage, re-power on to recover.
· Over temp.: TSW1(Power transistor) Temp. At 95± 5º C, shutdown o/p voltage; Temp. <95± 5º C, O/I auto-recovery.
· Remote control(option): CN1: 4-10VDC POWER ON, <0-0.8VDC POWER OFF
3) ENVIRONMENT
· Working Temp. & Humidity: -10º C~+60º C; 20%~90% RH.
· Storage Temp. & Humidity: -20º C~+85º C; 10%~95% RH.
· Vibration: 10~500Hz, 2G 10min. /1 cycle, period for 60min, each along X, Y, Z axes.
4) SAFETY STANDARDS
· Withstand Voltage; I/P-O/P: 3KVAC; I/P-FG: 1.5KVAC; O/P-FG: 0.5KVAC
· Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG: 100MΩ /500VDC
· Safety Standards: Design refer to UL1950, TUV, EN60950
· EMC Standards: Design refer to EN55022, EN61000-3-2, -3, EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, EN55024
5) Type No Output Tol. R&N Effi.
HSP-150-3.3 3.3V, 30A ± 2% 100mV 67%
HSP-150-5 5V, 30A ± 2% 100mV 75%
HSP-150-7.5 7.5V, 20A ± 2% 100mV 79%
HSP-150-12 12V, 12.5A ± 2% 100mV 80%
HSP-150-13.5 13.5V, 11.2A ± 2% 100mV 80%
HSP-150-15 15V, 10A ± 2% 100mV 81%
HSP-150-24 24V, 6.3A ± 1% 150mV 83%
HSP-150-27 27V, 5.6A ± 1% 150mV 84%
HSP-150-48 48V, 3.2A ± 1% 250mV 84%