switchgear
CCC, ISO9001, IEC, IEEE, CNAS
Steel Plate
High Voltage
Removable
Floorstanding
a
Customize
up to 35kv
up to 3000A
up to 480V
up to 6300A
50 Hz/60 Hz
IP2X/IP4X
IEC, IEEE, CNAS
KERUN
Export Standard Wooden Case
Customize
China
85353011
Product Description
 
LV Switchgear

Technical Description

Rated power: Customized
Rated voltage: up to 480V
Rated Current: up to 6300A
Frequencies: 50 Hz/60 HZ
Protection level: P2X/IP4X


MV And HV Switchgear

Technical Description

Rated power: Customized
Rated voltage: up to 35kV
Rated Current: up to 3000A
Frequencies: 50 Hz/60 HZ
Protection level: IP2X/IP4X
 

KYN61-40.5 INDOOR AC ARMOURED MOVABLE HIGH VOLTAGE SWITCHGEAR

No.Project NameUnitData
1Rated VoltagekV405
2Maximum Rated CurrentA2000
3Rated Breaking CurrentkA2531.5
4Rated Making Current(Peak Value)6380
5Limiting Th rough-current(Peak Value)6380
64s The rmal Stability Current(Effective Value)2531.5
7
Rated
Insulation
Level
1 min Power Frequency Withstand Voltage(Effective Value)kV95
Lightning Impulse Withstand Voltage(Peak Value)185
lsolating Fracture 1 min Power Frequency Withstand Voltage(Effedive Value)110
Isolation Fracture Lightning Impulse Withstand Voltage(Peak Value)215
8Boundary Dimension(WxD×H)mm1918×3250×3125
9Level of Protection IP2X
10Weightkgabout 1500

• KYN61-40.5 indoor AC armoured movable high voltage switchgear is using high quality coated aluminium zinc plate processing production. With flexible operation, strong interchangeability, stability, high safety performance, high intelligence etc merit. Can matching with domestic, import ZN85-40.5 breaker to use.
•  Apply to power plant(station), substation(distribution room ) and industrial, business, building etc.
• Implement GB3906 national standards.



XGN17-40.5 INDOOR AC BOX TYPE FIXED HIGH VOLTAGE SWITCHGEAR

No.Project Name
Unit

Data
1Rated VoltagekV40.5
2Rated CurrentThe Rated Current of Main BusA630,125,016,002,000
Rated Current with Circuit BreakerA630,125,016,002,000
3Rated Insulation Level1 Min Power Frequency Withstand Voltage Interpolar/between fracturekV95/110
Lightning Impulse Withstand Voltage(peak)interpolar,between phase to
the earth/between Fracture
kV185/215
The power frequency withstand voltage of auxiliary circuit,control circuitV/1min2000
4Rated FrequencyHz50
5Rated Short Circuit Breaking CurrentkA20,25,315
6Rated Short-time with stand current/Rated duration of short-CircuitkA/4s20,25,315
7Rated Peak Withstand CurrentkA50,63,80
8Rated Short-circuit Making CurrentkA50,63,80
9Rated Voltage of Controling loopVDC:110,220V AC:110,220V
10Interphase Centre Distancemm300
11Level of Protection IP4X
 IP2X
12Weightkg2400


• XGN17-40.5 indoor AC box type fixed high voltage switchgear is three-phase ac 50Hz(60Hz)subsection system of the indoor electric power equipment,has a large space,convenient maintenance etc merit.
• Apply to power plant(station), substation (distribution room) and industrial,business,building etc.
• lmplement GB3906 national standards.


KYN28 INDOOR AC ARMOURED MOVABLE HIGH VOLTAGE SWITCHGEAR

No.Project NameProject NameData
1Rated VoltagekV3,6,7.2,12,24
2Rated Insulation Level1min Power Frequency Withstand VoltagekV42
Lightning Impulse Withstand VoltagekV75
3Rated FrequencyHz50
4Main Bus-bar Rated CurrentA63,012,501,600,200,000,000,000,000,000,000,000
5Branch Busbar Rated CurrentA63,012,501,600,200,000,000,000,000,000,000,000
64S Thermal Stability Current(Effective Value)kA16,20,25,31.5,40,50
7Rated Dynamic Current(Peak Value)kA40,50,63,80,100,125
8Level of ProtectionShell ls IP4X,Isolation Room,when Circuit Breaker Room Door Opened is IP2X
9Weightkg1000

• KYN28 indoor AC metal armoured movable high voltage switchgear is using high quality aluminum zinc coated steel plate process and making. With flexible ope ration, strong inter changeabllity, stability, high safety performance, high intelligence etc merit Can matching with domestic, import breaker to use.
• Apply to power plant(station),substation(distribution room) and industrial, business, building etc.
• Implement GB3906 national standards.



XGN2-12 INDOOR HIGH VOLTAGE AC BOX TYPE SWITCHGEAR

No.Project NameUnitData
1Rated VoltagekV3,6,7.2,12
2Rated CurrentA630~3150
3Rated Short-Circuit Breaking CurrentkA20,25,31.5
4Rated Short-circuit Making Current(Peak Value)kA40,50,80,100
5Rated Withstand Current(PeakValue)kA40,50,80,100
6Rated Short Time Withstand CurrentkA20,25,31.5,40
7Rated
Insulation
Level
1 min Power Frequency
Withstand Voltage
Interpolar,between Phase
to the Earth/between Fracture
kV24,32,42
kV28,38,48
Lightning Impulse
Withstand Voltage
Interpolar,between Phase
to the Earth/between Fracture
kV40,60.75
kV46,70,85
8Rated Duration of Short-circuitS4
9Level of Protection IP2X
10Structural Style Single Bus-bar Section And Single Bus-bar With By pass
11Operating Mode Electromagnetic Type,Spring Energy-storage Type
12Boundary Dimension(W×D×H)mm1200x1300x2650(≥2000A)
1100x1200x2650(General)
13Weightkg≈1000


• XGN2-12 indoor high voltage AC box type switchgear has merits of independent function room,flexible operation,convenient maintenance,stability,high safety performance,high intelligence and others.
• Apply to power plant(station),substation(distribution 
room) and industrial,business,building etc.
• Implement GB3906 national standards.


XGN66-12 INDOOR HIGH VOLTAGE AC BOX TYPE SWITCHGEAR

No.Project NameUnitTechnical parameter
1Rated VoltagekV10
2Maximum Wo rking VoltagekV12
3Rated F requencyHz50
41min Power FrequencyWithstandVoltagekVnte rphase And Relatively42,Isolating Fractu re48
5Lightning Impulse Withstand VoltagekVnterphase And Relatively To75,Isolating 85
6Main Bus-bar Rated CurrentA630
7Load
Switch
Rated CurrentA630
8Mechanical LifeTime5000
9Breaking No-load Transformer CapacitykVA1250
10Rated Thermal CurrentkA20(4S)
11Rated Dynamlc CurrentkA50(PeakValue)
12Rated Making CurrentkA50(PeakValue)
13Composite
Apparatus
Fuse Maximum Rated CurrentA100
14Rated Transfer CurrentA1500(2000)
15Rated Short Circuit Breaking CurrentkA31.5
16Power Distribution Fuse Type S -LAJ-12(XRNT-10)
17Maximum Rated Capacity of Distribution TransformerkVA1250

• XGN66-12 indoor high voltage AC box type switchgear have merits of small size,economical and practical price, flexible and convenient operation and others.
• Apply to power plant(station), substation(distribution room) and industrial, commercial, construction field and box-type lransformer substation.
• Implement GB3906 national standards.




SRM 12/24 FULLY INSULATED FULLY SEALED COMMON BOX TYPE RING NETWORK SWITCHGEAR

Project NameC ModuleFModuleV ModuleC BModule
Load SwitchCombination SwitchVacuum Switchlsolation Earthing SwitchVacuum Circuit Breakerlsolation Earthing Switch
Rated Voltage(kV)12124
Rated Current(A)630125630 1250/630 
Frequency Withstand Voltage(kV)42150
Lightning Impulse Withstand Voltage (kV)95/125
Short-time Withstand Current(kV/S)25/2 2016/32016/32520/32520/3
Short Circuit Breaking Current(kA) 31.520/16 25/20 
Mechanical Life(Time)500030005000200050005000
SF6 Gas Pressure(bar)1.4
Environmental ConditionsTemperature 40ºC~-25ºC       Humidity<95%


• SRM 12/24 type fully insulated and totally sealed common box type ring network switch cabinet (referred to as inflatable cabinet) is a new generation of miniaturized modular switchgear. It has the advantages of compact structure, fully enclosed, fully insulated, long life,maintenance-free, small footprint, safe and reliable, and not affected by the working environment.
• Suitable for small secondary power stations, opening and closing stations, industrial and mining enterprises, airports, railways, commercial areas, high-rise buildings, highways, subways, tunnels and other fields.
• Implement the GB3906 national standard.




HXGN15-12 INDOOR HIGH VOLTAGE METAL ENCLOSED SWITCHGEAR (SF6 RING NETWORK CABINET)

Project NameUnitTechnical parameter
Rated VoltagekV12/24
Rated Lightning Impulse Withstand VoltageSame and OppositekV75/125
Between FracturekV85/145
1 min Power Frequency Withstand VoltageSame and OppositekV42/65
Between FracturekV48/79
Rated FrequencyHz50/60
Rated CurrentMain BusA1250/630
Branch BusA1250/630

Rated Short-time Withstand Current
Main CircuitkA20/3S
Earthing CircuitkA20/2S
Rated Peak Withstand CurrentkA50
Transfer CurrentA1700/800
Protection Level IP3X
Load Switch Mechanical LifeTime2000
Earthing Switch Mechanical LifeTime2000


•  HXGN15-12 series is a new generation of metal-enclosed switchgear with sulphur hexafluoride switch as main switch and air insulated whole cabinet for distribution automation. It is compact and expandable. It has simple structure, flexible operation, reliable interlocking and installation. Convenient and other features, can provide a satisfactory technical solution for a variety of different applications and different user requirements.
•  Applicable to urban residential area distribution, small secondary substation, opening and closing, industrial and mining enterprises, shopping malls, airports, subways, wind power, stadiums, railways, tunnels and other fields.
•  Implement the GB3906 national standard.



GTXGN-12V TYPE SOLID INSULATED SWITCHGEAR

Project NameUnitProduct Category
Load SwitchCombination SwitchBreakerIsolation Switch
Rated VoltagekV12121212
Arc Extinguishing Type VaccumVaccumVaccum 
Rated CurrentA630125630630
Rated FrequencyHz50505050
Main Circuit ResistancemQW150< 500 Note 1W150W150
1 min power frequency withstand voltage:Same and Opposite/Between FracturekV42/4842/4842/4842/48
Rated Lightning Impulse Withstand Voltage:Same and Opposite/Between FracturekV75/8575/8575/8575/85
Rated Short-Circuit Breaking CurrentkA-315  Note 220 -
Rated Short-Circuit Making CurrentkA5080 Note 250 -
Rated Short-Time Withstand CurrentkA/s20/4-20/4 -
Rated Peak Withstand CurrentkA5080 Note 250 -
Rated Cable Charging Breaking CurrentA10 - - -
5% Rated Active Load Breaking CurrentA315 - - -
Transfer CurrentA-3150- -
Average Closing Speedm/s09±0.2 -
Average Opening Speedm/s13±0.2 -
Opening and Closing at Different Timesm/sW2 -
Closing Timem/s25-60 -
Opening Timems17-45 -
Closing Bounce TimemsW2 -
Mechanical LifeTimeLoad switch/circuit breaker: 10000; isolation, grounding switch: 3000 
Protection Level IP67
Partial Discharge ValuePcNote 1


• GTXGN-12V solid insulated switchgear adopts modular structure design to realize any combination and expansion of switchgear cabinet for easy maintenance and maintenance. Fully insulated, fully sealed, maintenance free, all live parts are fully insulated. Fully insulated busbars are used for longitudinal arrangement, which is convenient and reliable. It has an independent lowvoltage room, which can be equipped with computer protection and various meters. It does not need to install a low-voltage chamber on the top of the cabinet to make the switch cabinets more beautiful and compact. It has an independent low-voltage room, which can be equipped with computer protection and various meters. It does not need to install a low-voltage chamber on the top of the cabinet to make the switch cabinets more beautiful and compact.
• Implement the GB3906 national standard.



MLS-V LOW VOLTAGE SWITCHGEAR OF DRAWER MODEL

Project NameTechnical parameter
Rated operational Voltage(V)  Main Circuit  ≤AC 400V
  Auxiliary Circuit  ≤AC380V,≤DC 220V
Rated Insulation Voltage (V)  Main Circuit  AC690V
Rated Impulse Withstand Voltage(1.2/50us)kV  Main Circuit  6,8
Rated Operating Current(IP4X time)*A  Main Bus-bar  ≤5000,≤3600(MLS Double side cabinet)
  Vertical Bus  790 1000 1250 1600 (Draw out type),≤2500 (Plug in type MCCB)
Rated Short Time withstand Current kA/1s  Vertical Bus  50,65,80,100
  Main Bus-bar  50,65,80,90
Rated Peak-value Withstand Current kA/0.1 s  Main Bus-bar  105,143,176,220
  Vertical Bus  105,143,176,198

• MLS low voltage switchgear of drawer model is the die standard parts by the factory assembly (FBA) of low voltage switchgear, applicable to AC 50 (60 Hz), rated working voltage is less than or equal to 400V, 5000A rated current and the following in power supply and distribution system, as the electrical distribution, conversion, control and reactive power compensation with.
• Implement GB7251.k GB7251.12, JB79661,IEC60439-1,BS EN60439-1 standards.



MDMAX ST LOW VOLTAGE SWITCHGEAR OF DRAWER MODEL

Project NameTechnical parameter
Rated Voltage (V)   Rated Insulation Voltage690V/1000V AC,3P,1500V DC
   Rated Operational Voltage400V/690VAC,3P,750VDC
   Uimp Rated Impulse Withstand Voltage6/8/12kV
   Overvoltage LevelI/II/IV
   Class of Pollution3
   Rated Operating FrequencyTo 60 Hz
Rated CurrentMain Bus-bar   Rated CurrentTo 6300A
   Rated Peak-value Withstand CurrentTo 220kA
   Rated Short Time withstand CurrentTo 100kA
Distribution Bus   Rated CurrentTo 2000kA
   Rated Peak-value Withstand CurrentTo176kA
   Rated Short Time withstand CurrentTo 80kA


• Mdmax ST low voltage switchgear of drawer model frame adopts aluminum zinc coated plate double folding technology, top level bus area can be removed, with drawer type, movable type, insert three functional units. The drawer type structure, the highest can assemble 36 loop. Without reducing the protection degree of the state, can achieve three drawer position loop conversion, the drawer can shift position matching parts, sound, light, three instructions, perfect drawer type electric circuit operation solutions.
• Implementation of GB7251.1-2013, IEC60439-1,EN60439.1, DIN-VDE0660, the 500th part of the BS5486, UTE63-410 standard.



GCS LOW VOLTAGE SWITCHGEAR OF DRAWER MODEL

Main Circuit Voltage Rating(V) AC380(400),(600)
Auxiliary Circuit Rate Voltage (V) AC200,380(440 )DC 110,220
Rated Frequency(Hz) 50(60)
Rated Insulation Voltage (V) 660(1000)
Rated Current(A)Horizontal Bus ^4000(6300
Vertical Bus(MCC)1000
Busbar Rated Short-time withstand current(kA/1s) 50,80
Busbar Rated Peak withstand Current (kA)105,176
Power Frequency Test Voltage(V/1 S)Main Curcuit2500
Auxiliary Curcuit2000
BusbarThree-Phase Four-Wire System A,B,C,PEN
Three-Phase Five-Wire System A.B.C.PEN
Level of Protection IP30
Weight(kg)650

• GCS low voltage switchgear of drawer model with flexible electrical scheme, convenient combination, strong practicality, strong interchangeability, flexible operation, convenient maintenance, high degree of protection etc merit.
• Apply to power plant (station), substation (distribution 
room) and industrial, business, building etc.
• Implement GB7251 national standards.


GCK LOW VOLTAGE SWITCHGEAR OF DRAWER MODEL

Project NameTechnical parameter
Rated Insulation Voltage(V)   AC660
Rated operational Voltage (V)   AC380
Rated Frequency   50
Level of Protection   IP30
Rated Current (A)Horizontal Bus   630-3150
Vertical Bus   630-1000
Main Circuit connectors   125,200,400
Control Circuit connectors   20
Maximum Current Feeding Circuit   1600
Withstand Electric Circuit Current   630-3150
Rated Short-time Withstand Current (kA)Effective Value  30,50
Peak Value   63.105
Component Drop Capacity Coefficient   0.8le (le is the rated current of the component)
Unit Drawer Breaking Capacity(kV)   30-50*
The Auxiliary Circuit Working Voltage(V)   DC:110,220 AC:63 - 380

• GCK low voltage switchgear of drawer model with flexible electrical scheme, convenient combination, strong practicality, strong interchangeability, flexible operation, convenient maintenance, high degree of protection etc merit.
• Apply to power plant (station), substation (distribution room) and industrial, business, building etc.
• Implement GB7251 national standards.



MNS LOW VOLTAGE SWITCHGEAR OF DRAWER MODEL

Project NameTechnical parameter
Rated Insulation Voltage (V)Ac660
Rated operational Voltage (V)AC400
Rated Frequency(Hz)50
Level of ProtectionP30,IP40
Rated Current (A)   Horizontal Bus630-3150
   Vertical Bus630-1000
   Main Circuit Connectors125,200,400 
   Control Circuit Connectors32
   Maximum Current Feeding Circuit1600
   Withstand Electric Circuit Current630-3150

• MNS low voltage switchgear of drawer model with flexible electrical scheme, convenient combination, strong practicality, strong interchangeability, flexible operation, convenient maintenance, high degree of protection etc merit.
• Apply to power plant (station), substation (distribution room) and industrial, business, building etc.
• Implement GB7251 national standards.



GGD LOW VOLTAGE FIXED TYPE SWITCHGEAR


Model
Specifications

Rated Voltage
(kV)

Rated Current
(A)

Rated Short Circuit
Breaking Current
(kA)

Rated Short Time
Withstand Current
(kA/1 s)

Rated Peak
Withstand Current
(kA)
GGD10.4
(0.66)
A1000151530
B600(630)
C400
GGD20.4
(0.66)
A1500(1600)303063
B1000
C630
GGD30.4
(0.66)
A3150-63005050105
B2500
C2000


• GGD low voltage fixed type switchgear with flexible electrical scheme, convenient combination, strong practicality, flexible operation, convenient maintenance, etc merit.• Apply to power plant (station), substation (distribution room) and 
industrial, business, building etc.
• Implement GB7251 national standards.

LV And HV Switchgear Manufacturers:

 

KERUN engineers have 40 years of experience in the transformer industry and have accumulated a wealth of experience in participating in different projects in various countries. Based on project cooperation cases, KERUN can help you analyze the types of transformers you need in project construction and provide complete power distribution and other solutions.
 


Q:Who are you?
A:KERUNis a company in growth. We have reached many of our goals, and established solid marketing foundation in many countries. 

Q:Are you a manufacturer or a trading company? 
A:We are a professional transformer manufacturer with more than 20 year's experience.Support OEM&ODM.

Q:Which markets do you mostly export to? 
A:We are exporting to more than 20 countries in South America, North America, Europe, Middle East, Africa and so on.

Q:What certificates and standards do you have?
A:ISO9001-2008, OHSAS 18001:2007, ISO4001:2004L certificates. A:IEC, ANSI, KEMA, GOST standard.

Q:How long is your delivery time? 
A:After determining the plan, we will complete production and shipping within 20 days. It mainly depends on the quantity.

Q:What is the standard of package? 
A:Our nomal package are divided into three types:wooden pallets, wooden frames, and wooden boxes.Also it can be customized.

Q:What currencies and payment Type do you support?
A:Payment Currency:USD,CNY.
    Payment Type:T/T,L/C.

Q:Why choose KERUN?
A:After comparing the quality, delivery and price of the same products, believe you will choose KERUN.-
Message Type