Hydride Generator Used for Aas Atomic Absorption Spectrometry Hg-C

Price $2500.00 Compare
Min Order 1 set
Shipping From Shandong, China
Popularity 418 people viewed
Quantity
+-
 

Jinan Mao An Instrument Co., Ltd.

VIP   Audited Supplier 11 years
Profile Certified by SGS/BV
HG-C
Online
Laboratory Apparatus
1 Year
Spectrophotometer
High Sensitive
Classic Spectrometer
Visible Spectrometer
Grating Spectrometer
Polychromator
CE
Customized
Hydride Generator
Hg-C
for Aas, Icp Plasma
All The World Aas Brands
Continuous Sampling(Flame Type)
0-7ml/Min
0-2.5ml/Min
Single Pump
Ar,Supply Pressure 0.32MPa
220V
MAOAN
Carton
Jinan, Shandong, China
Product Description
Product Description
 

     HG-C hydride generator is applicable to various atomic absorption spectrophotometers(AAS) in China and abroad.Not only workable with AAS, also can work with ICP plasma and can be used for liquid phase, combined with UV for morphological  analysis .This instrument has memory function(one button start). Has exceeded international technology. At present, China's atomic absorption system 90% uses our HG-C model hydride generator. And foreign atomic absorption instrument manufacturers and ICP plasma manufacturers gradually use our company's hydride generator to replace imported hydride generators.

 

Working Principle

       Sample containing As, Se, Sn, or Bi elements, HCl and NaBH4 solution are fed into the manifold by the pump, mixed and sent to the reaction coil to generate hydride. The reaction mixture composed of hydride, hydrogen, water vapor and reagent residues are fed to the gas/liquid separator by carrier gas. In the separator, the gas phase is separated from the liquid and sent to the absorption cell by carrier gas, while the latter is drained.  The absorption cell is heated by the air-acetylene flame to pyrolyze hydride. (Inorganic mercury in the aqueous solution is vaporized as free mercury in the presence of reducing agent. Leading mercury vapor to the atomizer, the atomic absorption measurement can be made without heating. )
 

Product Parameters

Model No

                                   HG-C

Measurement mode

continuous flow method

Reducing agent

NaBH4

Sample aspiration

0-7ml/min

Reagent aspiration

0-2.5ml/min

Atomizer

heated absorption cell

(heated by the air-acetylene flame)

Carrier gas

Ar,supply pressure 0.32MPa

Sampling method

Continuous sampling(flame type)

Hg standard solution

5ng, light absorption value≥0.055A

As standard solution

2ng, light absorption value≥0.055A

RSD value

≤2% ( As 6ng standard solution)

R ( linearity)

>0.998%

Power

220V,50HZ,30VA

Dimensions

290×220×208mm

Weight

12kgs

 
Structure Diagram

Product Pictures

 

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA