IEC60044 Current Transformer Testing CT Meter Automatic CT PT Analyzer

Price $8000.00 Compare
Min Order 1 Piece
Shipping From Chongqing, China
Popularity 343 people viewed
Quantity
+-
 

Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.

VIP   Audited Supplier 11 years
Profile Certified by SGS/BV
GDVA-405 CT PT Analyzer
Lifetime Technical Support
1 Year for CT PT Analyzer
Current Transformer & Voltage Transformer Testing
Fully Automatic, Multi-Function, Touch Screen
IEC60044-1/6/2/5, IEC61869, C57.13
0.001-5A(RMS)
500va
0.02%(Typical), 0.1%(Guarantee)
60kv
1-35000
15kg
Engineer Available to Service Overseas
CT Analyzer
Packed in Plywood Case
15KG for net weight
Chongqing, China
9031809090
Product Description
IEC60044 Current Transformer Testing CT Meter Automatic CT PT Analyzer
 

Product Description

 

The GDVA-405 CT PT Analyzer is an advanced and state-of-the-art professional instrument specifically engineered to provide comprehensive testing and analysis capabilities for current transformers (CTs) and potential transformers (PTs). With its cutting-edge technology and precise measurement capabilities, this instrument plays a crucial role in the industry by facilitating accurate assessment and evaluation of transformer performance.

Built with the latest advancements in testing equipment, the CT PT Analyzer offers a wide range of features and functionalities that enable thorough examination of CTs and PTs. It is designed to meet the stringent requirements of the industry, ensuring reliable and accurate results.

Test Items


Test Items by GDVA-405 CT PT Analyzer:

Tests for Current TransformerTests for Potencial Transformer
1) Turn ratio detection
2) Ratio and angle error check
3) Polarity test
4) Excitation characteristic test
5) Secondary winding resistance measurement and secondary burden measurement
6) 5% and 10% error curve measurement
7) Transient characteristics analysis
8) Automatic nameplate inference
9) Knee point voltage/current
10) Accuracy Limit Factor (ALF)
11) Instrument security factor (FS)
12) Secondary time constant (Ts)
13) Remanence coefficient (Kr)
14) Accuracy
15) Saturation and desaturation inductance
16) Knee point electromotive force
17) Limit electromotive force
18) Area factor
19) Iron core analysis and core hysteresis loop measurement
1) Turn ratio measurement
2) Ratio and angle error check
3) Polarity test
4) Excitation characteristic test
5) Primary winding resistance test
6) Secondary winding resistance test
7) Secondary burden measurement

 

Technical Parameter


Technical Parameter of GDVA-405 IEC60044 Transformer CVT Test Machine CT Meter Automatic CT PT Analyzer 

1.Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC61869,IEC60044-5, C57.13
2.Power supply: AC220V±10%, 50/60Hz±10%
3.Voltage output: 0.1-180V (AC)
4.Current output: 0.001-5A(RMS)
5.Power output: 500VA
6.Maximum knee voltage measurement: 60KV
7.Current measurement:
   Range: 0-10A (automatically change range in 0.1/0.4/2/10A) 
   Error: <±0.1%+0.01%FS
8.Voltage measurement:
   Range: 0-200V (automatically change range in 1V/10V/70V/200V)
   Error: < ±0.1%+0.01%FS
9.Turns ratio measurement:
   Range:1-35000
   1-2000     error<0.05%
   2000-5000  error<0.1%
   5000-35000  error<0.2%
10.Phase measurement: error: ±2min; resolution: 0.01min.
11.Winding resistance measurement: 
    Range: 0-8kΩ (automatically change range in          2ohm/20ohm/80ohm/800ohm/8kohm)
    Error: < 0.2%RDG+0.02%FS
    Maximum resolution: 0.1mΩ
12.Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree.
13.CT Secondary burden:
    Range: 0-160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
    Error: <0.2%RDG+0.02%FS 
    Maximum resolution: 0.001ohm
14.PT Secondary burden:
    Range: 0-80kohm (automatically change range in 800ohm/8kohm/80kohm)
    Error :<0.2%RDG+0.02%FS 
    Maximum resolution: 0.1ohm
15.PT ratio measurement:
    Range: 1-35000
    1-10000 error<0.1%
    10000-35000 error<0.2%
16.PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%.
17.PT phase angle measurement: maximum error < 3min.
18.Memory capacity: >1000 groups test results.
19.Working condition: temperature: -10ºC~50ºC; moist: ≤90%
 
Other Functions:
IEC60044 Current Transformer Testing CT Meter Automatic CT PT Analyzer 

1) Make evaluation for test results according to selected standards.
2) Make word report for test result.
3) Make word reports one time for multi-group test records on the PC.
4) Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.
5) Compare excitation curves with saved excitation curves in the same window.

 

Testing Site

 

 

About Us

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA