IVY Factory Direct Stable Bistale Relais 2 Phases 80A 90A 12VDC Coil Latching Relay

Price $3.96 Compare
Min Order 1 Piece
Shipping From Shanghai, China
Popularity 327 people viewed
Quantity
+-
 

IVY METERING CO., LTD.

VIP   Audited Supplier 7 years
Profile Certified by SGS/BV
IM901D
Electromagnetic Relay
Household Appliances Relay, Energy Meter, Industrial Control, EV Charger
2
Ac
2
High Power Relay
Enclosed Relay
Electromagnetic Type
Miniature
Electric Parameter Relay
2 Phases 90A 12VDC Coil Latching Relay
90A, 250VAC
Agsno2
6~24VDC
Black
IVY
Cartons/Pallet
60*34.5*19mm
Zhejiang, China
8536411000
Product Description

Parameter CategoryParameterValue/Specification
General ParametersMain Dimensions60 * 34.5 * 19 mm
Weight80g (excluding peripheral accessories)
Operating Temperature-40 to +85 °C
Operating Humidity45% to 95% RH
Contact ParametersContact MaterialAgSnO2
Contact Form2A or 2B (2 sets of Normally Open or Normally Closed)
Contact Resistance≤ 0.8 mΩ (initial value, @DC 6~24V, 1A)
Maximum Switching Current90A
Maximum Switching Voltage250VAC
Performance ParametersRated Coil VoltageDC 6, 9, 12, 24V
Pulse Duration100ms ~ 200ms (recommended)
Rated Coil Power2.5W (single coil), 5W (dual coil)
Pick-up Time≤ 30ms
Release Time≤ 30ms
Electrical Life10,000 operations (purely resistive load, 90A 230VAC)
Mechanical Life100,000 operations
Insulation Resistance1000 MΩ (500VDC)
Coil to Contacts4000VAC, 50/60Hz, 1 min
Between Different Contact Groups4000VAC, 50/60Hz, 1 min
Across Open Contacts of Same Group2000VAC, 50/60Hz, 1 min
Short-Circuit Current Withstand4500A (50/60Hz), ~10ms (non-explosive)
Shock Resistance (Functional)100 m/s² (10G)
Shock Resistance (Destructive)1000 m/s² (100G)
Vibration1.5mm (double amplitude), 10~55Hz

Dimension and Wiring




Company Profile

 

          Cautions of Latching Relay:

             1.Suggestions of relay's input
            (1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,
            you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory.
            (2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
            times or 2 times of value or lower driving condition plz confirm with our engineer.
            (3)Relays'contact status may be changed during transportation or installation due to impact of external force,
            therefore please reset to the required status.
 
            2.Suggestions of relay's output
            (1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
            the installation.
            (2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection is
            fastened and prevent relay from damages or other safety problems due to temp. Rise..