Inductively Coupled Plasma Emission Spectrometer for Oil and Oil Products Detections

Price $37233.00 Compare
Min Order 1 Set
Shipping From Shanghai, China
Popularity 335 people viewed
Quantity
+-
 

Macylab Instruments Inc.

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
ICP 6800S
Online Technical Support
Laboratory Apparatus
1 Year
Spectrophotometer
High Resolution
Classic Spectrometer
Visible Spectrometer
Grating Spectrometer
Monochromator
RoHS, ISO9001, CE
Customized
Icp-6800s
Rsd <1.5%
27.12MHz±0.05%
< 0.1%
Czerny-Turner
Macylab
Carton
360*
China
9027300090
Product Description
Detailed Product Description

Name:Inductively Coupled Plasma Optical Emission SpectrometerOutput Power:800 -1200W
Frequency:27.12MHz±0.05%Frequency Stability:< 0.1%
Stability:RSD <1.5%Output Power Stability:< 0.3%
WxDxH:125x69.3x64.5cmWeight:205kg
High Light:

inductively coupled plasma emission spectrometer

1200w inductively coupled plasma emission spectrometer

inductively coupled plasma atomic emission spectroscopy

 
 
ICP-6800s Inductively Coupled Plasma Optical Emission Spectrometer

 Petrochemical Inductively Coupled Plasma Optical Emission Spectrometer(ICP6800S) is a professional instrument for the petrochemical industry launched by Macylab Instruments. It can be used to determine more than 30 elements in crude oil, mainly for Fe, Na, Mg, Ni, V, Ca, Pb, Mo, Mn, Cr, Ca, Ba, As; also can be used to measure Fe, Mg, Pb, Si in gasoline ,and the wear elements of additive in lubricating oil, it also can be applied for multielement determination in base oils; for the determination of sodium in formaldehyde and the determination of oil field tracer.
 

Main Features

 

Performance stability

The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient.

 

Injection automation

Adopting four-channel automatic design, the rotational speed can be set up according to the test demand to adjust the flow rate, carrier gas, plasma gas, auxiliary gas are all controlled by advanced mass flow controller, at the same time can be equipped with imported high salt nebulizer, imported hydrofluoric nebulizer and so on to meet the customer's various test needs.

 

Precision analysis

The middle step grating prism cross dispersion mode is adopted, there is no moving optical element, the ultra low stray light design is combined with the unique optical design, nitrogen distributed blowing, imported optical elements, intelligent and accurate automatic wavelength calibration algorithm.

 

Quick test

In American thermoelectric CID detector, the 160-1000nm range is continuously covered, and the intensity integral values of all analytical spectral lines are read out at one exposure to speed up the analysis.

 
Product Parameters

 

RFPower technical parameter

Circuit type

solid-state RF Power supply, with function of automatch

Frequercy

27.12MHz±0.05%

Frequency Stablity

<0.1%

Power Output

800W-1500W

Power Output Stability

<0.3%

Escaped RF radiation

30cm away from the instrument, electric fiekd: E<2Vtm

Sampling System Technical Parameter

Output working coil imer diameter

25mm

Torpue tube

Three concentric, extemal diameter 20mm

Coaxial nebulizer

Outer dameter 6mm

Double barrel atomizing chamber

Outer diameter 34mm

 

Gas Flow Controls

Plasma Argon Flowmeter

(100-1000)L/h(1.6-16L/min)

Auxiliary Argon Fiowmeter

(100-1000)L/h(0.16-1.6L/min)

Auxiliary Carrier Argon Flowmeter

(100-1000)L/h(0.16-1.6L/min)

Pressune Maintaining Value

(0-0.4MPa)

Cooling Water:Temperature

20-25ºC,Rate of Flow>5L/min,Hydraulic Pressure>0.1MPa

 

Spectrometer

Optics

Czerny-Turner type

Focal length

1000 mm

Grating

Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm

Reciprocal linear dispersion

0.26nm/mm

Resolution

≤0.007nm(3600 line grating); ≤0.015nm(2400 line grating)

Wavelength range

3600 line grating:(190nm~500) nm; 2400 line grating:(190nm~800) nm

Minimum pace of stepping motor

≤0.0006 nm

Exit Slit

12μm

Entrance Slit

10μm

 

Photoelectric Converter Performance

Photomultiplier tube specification

R293/R928

Negative HV on PMT

0-1000V

Stability

<0.05%

 

Direct injection sampling and measure iron(Fe), manganese(Mn), lead(Pb) and silicon(Si) in gasoline.Analysis results:

ElementFeMnPbSi
Determination value/(mg/L)3.617.51.82.4
RSD/%0.560.231.380.92


Standard Addition Recovery Rate:

NumberStandard Addition
(mg/L)
FeMnPbSi
  Determination value(mg/L)Recovery
/%
Determination value(mg/L)Recovery
/%
Determination value(mg/L)Recovery
/%
Determination value(mg/L)Recovery
/%
10.450.43696.90.468104.00.43296.00.465103.3
20.90.88798.60.913101.40.86896.40.919102.1

 

 

Application Fields

 

 

Application Fields

Certificates


Application FieldsApplication Fields

 

Company Profile

 

 

Exhibitions
 

 

 

                                                                                                                           Application Field                                                                                                                          Certificate                                                                                                 Company profile                                                                       

 
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA