Industrial Generator 500/1000/1500/1800/2000/2250/2500kVA Cummins Perkins Mitsubishi Sme Baudouin Yuchai Weichai Engine Standby Silent Diesel Power Generators

Price $200000.00 Compare
Min Order 1 SET
Shipping From Fujian, China
Popularity 207 people viewed
Quantity
+-
 

Mecca Power Co., Limited

VIP   Audited Supplier 7 years
Profile Certified by SGS/BV
MC
Responsible
12 Months
Self-Starting Diesel Generator
Fixed
Four Stroke
Water Cooling
AC Three Phase
Low Speed
Land Use
Common Units, Standby Unit, Emergency Crew
Automation Type
Static Exciter
Perkins
Stamford/Marathon/Mecca and Unique Brand for Usage
Deepsea/Comap/Datakom/Delixi/Smartgen and Others
Optional
Silent Sound Proof/Weather Proof/Anti-Rusted Proof
50Hz/60Hz
220-440V 1500rpm, 110-480V 1800rpm
Building Standby/Hospital/Construction
Spare Parts Document
Mech/Elec/ECU/Ecm/Hpcr/Adec
Global Service
as Application Requested
CE, ISO, OEM Authorization etc.
Power Generator Set
Power Generation
Mecca
Both Standard Marine Packing or Compact Packing.
As below Spec. with details
China
85021100
Product Description
Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators.

With more than 10 years of experience in manufacturing and exporting energy products, the Mecca team will advise you on product choices. 

Generator Introduction

Silent/Open/Containerized Type diesel generator with Perkins Engine for construction/factory/building/power plant

-Power by Doosan/Yanmar/Perkins engine
-With Stamford / Leroy Somer / Marathon alternator
-With ABB MCCB & Electronic Components
-Electric start with battery
-10 hours Lasting Base Integrated fuel Tank
-Strictly comply with ISO9001/CE 
-24*365 hours global after-sale services
-Option:ATS, Deepsea / ComAp controller
-All sets COO Certificate


VIEW MORE PRODUCTS CLIK HERE...
Specification
Powered by  Perkins                                                                                                                                        50HZ    220-440 V 10-2500KVA 
ModelLTPPRPEngine
KVA / KW KVA/KW ModelOrigin
MC10P1097403A-11G1CN/UK
MC10P1097403D-11GCN
MC14P1411 1310403A-15G1CN
MC14P1411 1310403D-15GCN
MC16P1613 1512403A-15G2CN
MC23P2318 2016404A-22G1CN
MC23P2318 2016404D-22GCN
MC30P30242822404D-22TGCN
MC33P3326 30241103A-33GUK/IN
MC50P5040 45361103A-33TG1UK/IN
MC66P6653 60481103A-33TG2UK/IN
MC72P7257 65521104A-44TG1CN
MC88P8870 80641104C-44TAG1CN
MC88P8870 80641104A-44TG2CN
MC113P11390 100801104C-44TAG2CN
MC150P150120 1351081106A-70TG1CN
MC165P165132 1501201106A-70TAG2CN
MC200P200160 1801441106A-70TAG3CN
MC220P220176 2001601106A-70TAG4CN
MC220P220176 2001601206A-E70TTAG1UK
MC250P250200 2251801506A-E88TAG2USA
MC250P250200 2251801206A-E70TTAG2UK
MC275P275220 2502001206A-E70TTAG3UK
MC339P339271 3062451706A-E93TAG1USA
MC383P383306 3482781706A-E93TAG2USA
MC275P275220 2502001506A-E88TAG3USA
MC330P330264 3002401506A-E88TAG5USA
MC400P400320 3502802206C-E13TAG2USA
MC450P450360 4003202206C-E13TAG3USA
MC500P500400 4503602506C-E15TAG1USA
MC550P550440 5004002506C-E15TAG2USA
MC660P660528 6004802806C-E18TAG1AUSA
MC715P715572 6505202806A-E18TAG2USA
MC825P825660 7506004006-23TAG2AUK/IN
MC880P880704 8006404006-23TAG3AUK/IN
MC1000P1000800 9007204008TAG1AUK/IN
MC1100P1100880 10008004008TAG2AUK/IN
MC1100P1100880 10008004008TAG2UK/IN
MC1250P12501000 11259004008-30TAG3UK/IN
MC1375P13751100 125010004012-46TWG2AUK/IN
MC1500P15001200 135010804012-46TWG3AUK/IN
MC1650P16501320 150012004012-46TAG2AUK/IN
MC1875P18751500 168813504012-46TAG3AUK/IN
MC2000P20001600 185014804016TAG1AUK/IN
MC2250P22501800 200016004016TAG2AUK/IN
MC2500P25002000 225018004016-61TRG3UK/IN
MORE SEPC. CONTACT US...
Genset Workshop

FAQ

1.Q: What is your MOQ of this item?
A:1 Set

2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight

3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.

4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples

5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.

6.Q:Do you offer OEM service?
A: Yes

7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva

8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.

 

Item
 

Service
 

Option
 

Delivery Time
 
1EngineDoosan, Mtu, Mitsubishi, SME,  Volvo, 
Deutz, Yanmar, Faw, YangDong, Aoling, Yuchai, Lovol, Wandi, ect.
Marine and industry use 
Diesel, gas
2-45days
2AlternatorStamford, Leroysomer,  Meccalte,  Marathon  and 
customer requested alternators
Medium and high voltage, 
Marine and industry use 
High IP Grade
CT Drop kits, PMG, AVR
2-15 days
3RadiatorFast, Beworld brand
Original Radiator come with engine
Local made radiator with authorization by engine supplier
2-7days
4CanopiesPowder coated and form mounted canopy,completely break down with hings,
locks, raincap,bolts,screws, etc.
Exhaust pipe and flanges 
Standard silent type canopy package 
Denyo type canopy package 
Rental type canopy package 
Telecom type canopy package 
Super silent type canopy package 
Containerized type canopy package 
Customerized type canopy package
10days
5Base frameStandard base or simple iron base
Anti-Vibration mountings
With/without tank, base tank volume no limited
Fuel gauges and high pressure fuel pipes
3days
6Control systemController: ComAp, DeepSea, Datacom, SmartGen etc.
Breaker:Delixi,ABB, Chint, etc.
Battery switch, battery charger, emergency stop botton, 
indicator, meters, CT and all wiring and harness.
Batteries and cables
Speed & lub oil & water temp sensors,
A package of standard parts for assembly
3days
7Exhaust SystemIndustrial and residential silencer
Flexible connects and elbow
3days
8
Others
 
Special demands 

-----------------------------------------------------------------------------------------------MAITAINENCE-------------------------------------------------------------------------------------------

General Troubleshooting          

This section lists the generating set for some common fault, the reasons for the failure and determines the           
method of fault. General operators can determine their own fault and note, maintenance it according to the           
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.           
Please remember the following suggestions before repairing:           
- Make sure that study the failure carefully before any operation.           
- Repair with the easiest way and most commonly used method.           
- Find the exact causes of failure and completely solve the fault.     
   

1. Generator Sets          
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.           
(Some models of control panel installed only parts of the following warning indicator light)
IconIndicator LightReasonFault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.


Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary