Infitek -86 Degree Ultra-Low Temperature Freezer Dual refrigeration system Lab Medical Freezer Vaccine Freezer
Key Design Features
Microprocessor-controlled system designed for controlled rage of -40ºC to - 86ºC for cabinet space with 1ºC increment.
Settable high temperature and low temperature alarms.
Automatic clean-filter alarm and sensor error alert.
Adjustable storage shelf height.
Optional temperature recorder, storage racks and storage box.
Double security with two independent cooling system, when one system breakdown, the other system could maintain the inner temperature at -70ºC. (Only for P series)
Safety
Multifunction alarms including high and low temperature, power failure, sensor error, clean-filter, and extremely high ambient, abnormal voltage, thermostat failure, low battery, condenser clean, door ajar.
Capable of producing two types of alarm outputs, audible buzzer and visible flashing light.
Door open feature standard and USB port for temperature date downloading standard on upright models.
Remote alarm contacts.
Installation and Application
Wide rage operating voltage system from 187V to 242V designed to allow units installed in areas with poor voltage condition.
Suitable for 10ºC to 32ºC ambient temperature.
Filed Proven Reliability
Unique insulated inner door design for four separate storage compartments to minimize frost buildup inside the chamber.
Specialized control system design for a well-balanced operation of cascade(dual) refrigeration system.
Positive filed proven reliability record.
Energy Saving
Unique door seal design for the minimum loss of cold temperature during a door opening.
High performance VIP insulation panels to minimize cabinet heat gain and to improve temperature stability.
Model | ULF86-410P | ULF86-590P | ULF86-730P | ULF86-840P | |
Specifications | Shelf/drawer QTY | Stainless steel shelf/3 | Stainless steel shelf/3 | Stainless steel shelf/3 | Stainless steel shelf/3 |
Cooling | Direct cooling | Direct cooling | Direct cooling | Direct cooling | |
Defrost | Manual | Manual | Manual | Manual | |
Refrigerant | Mixed-gas | Mixed-gas | Mixed-gas | Mixed-gas | |
Power Consumption(kWh/24h) | 14.5 | 16.5 | 18.8 | ||
Noise(db) | 53 | 53 | 53 | 55 | |
Ambient temperature(ºC) | 10~32ºC | 10~32ºC | 10~32ºC | 10~32ºC | |
Temperature range(ºC) | -40~-86ºC | -40~-86ºC | -40~-86ºC | -40~-86ºC | |
Cooling system | Compressor brand/QTY | SECOP/2 | SECOP/2 | SECOP/2 | SECOP/2 |
Sensor | PTC | PTC | PTC | PTC | |
Temperature controller | Microprocessor | Microprocessor | Microprocessor | Microprocessor | |
Display | LCD display | LCD display | LCD display | LCD display | |
Power | Voltage/frequency(V/Hz) | 220/50Hz | 220/50Hz | 220/50Hz | 220/50Hz |
Power(W) | 1350W | 1500W | 1700W | ||
Current(A) | 8A | 9.1A | 9.8A | ||
Material | Inside material | 304 Stainless steel | 304 Stainless steel | 304 Stainless steel | 304 Stainless steel |
Outside material | Color sprayed steel | Color sprayed steel | Color sprayed steel | Color sprayed steel | |
Insulation | PURF | PURF | PURF | PURF | |
Size | Capacity(L/cu.ft) | 408 | 588 | 728 | 838 |
NT./GT.(kg) | 255/307 | 297.5/358.5 | 360/401.5 | 336.5/416 | |
Exterior size(W*D*H)(mm) | 900*940*1940 | 885*1100*1995 | 1260*890*2010 | 1190*1045*2010 | |
Interior size(W*D*H)(mm) | 606*575*1180 | 606*738*1310 | 963*558*1350 | 894*718*1310 | |
Package size(W*D*H)(mm) | 955*960*2100 | 970*1140*2190 | 1320*970*2190 | 1270*1105*2220 | |
CBM | 1.93 | 2.42 | 2.8 | 3.12 | |
20GP/40GP/40HQ | 12/24/24 | 12/24/24 | 8/18/18 | 8/18/18 | |
Frozen Racks | Racks | 16(5*4,4*4) | 16(5*5) | 18(5*4)+6(6*4) | 24(5*5) |
Boxes (2 Inches) | 288 | 400 | 504 | 600 | |
Samples(2ml) | 28800 | 40000 | 50400 | 60000 | |
Alarm | High/low temperature | Y | Y | Y | Y |
Power failure | Y | Y | Y | Y | |
Abnormal voltage | Y | Y | Y | Y | |
Sensor error | Y | Y | Y | Y | |
Filter screen check | Y | Y | Y | Y | |
Thermostat failure | Y | Y | Y | Y | |
Low battery | Y | Y | Y | Y | |
Condenser clean | Y | Y | Y | Y | |
High ambient temperature | Y | Y | Y | Y | |
Door ajar | Y | Y | Y | Y | |
Power failure backup system(alarm) | 72h | 72h | 73h | 72h | |
Accessories | Castor | Y | Y | Y | Y |
Inside door | 2 | 2 | 2 | 2 | |
Test hole QTY/diameter | 1/25MM | 1/25MM | 1/25MM | 1/25MM | |
USB port | Y | Y | Y | Y | |
Chart recorder | / | / | / | / | |
Data logger | Optional | Optional | Optional | Optional | |
Remote alarm port | Y | Y | Y | Y | |
Optional | CO2 back up system | Optional | Optional | Optional | Optional |
LN2 back up system | Optional | Optional | Optional | Optional |

Q: How about quality of the goods?
A:lAll the running products comply with CE standards.
lIndependent quality inspection team, conducting multiple inspections and random inspections from parts supply to product dispatch.
lWell-known third-party testing service available, such as SGS, BV, and TUV, etc.
Q: What are your pre- and after-sales services?
A:lTimely reply to pre-sales enquiries
lReal-time update of manufacturing and shipment status
lContracted third-party maintenance company in over 60 countries
lAssured availability of parts supply for 10 years at least
Q: Is OEM service available.
A: Most of the running products are available for OEM customization, including logo, package and function, if attainable, customization.
Q: How long is the lead time:
A: Generally, the lead time for most stocked products is about 7~15 days, vary by models and production schedule. For those non-stocked products, the manufacturing lead time is around 20 days.