LINK1000-4G
Two Years
Two Years
Digital
Direct Connected
Multi-Functional Energy Meter
Three-phase Four-wire
Electronic Meter
Feed-through Type
Energy Meter
ISO
Customized
Linkelec
Carton
Made in China
90283012
Product Description
Intelligent communication multi-channel energy meter
1.Product profile
The intelligent communication multi-channel energy meter is a new type of power monitoring and control energy meter that integrates measurement and recording, energy measurement, alarm output, and network communication functions. This electric energy meter can measure multiple grid parameters such as voltage, current, power, and residual current; Capable of configuring independent RS485 communication interface and 4G dual-mode communication, supporting MQTT communication protocol. It can achieve the monitoring of the operation status of 4 incoming and outgoing lines and branches, as well as the indication of fault status.
4.Product installation and schematic diagramThe intelligent communication multi-channel energy meter is a new type of power monitoring and control energy meter that integrates measurement and recording, energy measurement, alarm output, and network communication functions. This electric energy meter can measure multiple grid parameters such as voltage, current, power, and residual current; Capable of configuring independent RS485 communication interface and 4G dual-mode communication, supporting MQTT communication protocol. It can achieve the monitoring of the operation status of 4 incoming and outgoing lines and branches, as well as the indication of fault status.


2.Technical indicators
3.Selection specificationsperformance parameter | Performance index | |
accuracy class | Voltage: ≤ 0.5%; Current: ≤ 0.5%; Active power: ≤ 0.5%; Reactive power: ≤ 1%; Power factor: ≤ 0.5%; Apparent work | |
Rate: ≤ 1.0%; Electricity quantity: ≤ 0.5%; Frequency: ≤± 0.02Hz | ||
display mode | OLED LCD screen | |
Connection mode | Three-phase four-wire/three-phase three-wire | |
input voltage | rated voltage | AC220V |
frequency range | 45~65HZ | |
measuring range | 154V~286V | |
incoming current | rated current | The rated current is 100mA AC 300A/100mA. |
frequency range | 45~65HZ | |
measuring range | 10A~300A | |
working power supply | rated voltage | AC 220V (allowable deviation -20%~+20%) |
Power consumption | Not more than 3W | |
communication interface | Interface form | RS485,4G module |
protocol | ModbusRTU,MQTT | |
environmental conditions | Ambient temperature and humidity | Temperature range:-40 ~+70ºC |
Maximum temperature change rate: 1.0ºC/ min | ||
Relative humidity: 10 ~ 100% | ||
Maximum absolute humidity: 35g/m | ||
operational environment | There is no explosion danger, corrosive gas and conductive dust, serious mold and violent vibration shock source. | |
storage temperature | -40ºC~80ºC | |
Clock accuracy | Daily error | ≤0.5 seconds/day, supporting communication timing. |
functional module | serial number | Function point | Function point description | Intelligent AC multi-channel watt-hour meter |
Real-time measurement | 1 | phase voltage | Phase voltage: Ua, Ub, Uc | √ |
2 | line voltage | Line voltage: Uab, Ubc, Uca | √ | |
3 | Voltage sequence component | Voltage sequence components: U1, U2, U0 | √ | |
4 | phase current | Phase current: Ia, Ib, Ic | √ | |
6 | active power | Active power: Pa, Pb, Pc, p. | √ | |
7 | wattless power | Reactive power: Qa, Qb, Qc and Q. | √ | |
8 | apparent power | Apparent power: Sa, Sb, Sc, s | √ | |
9 | Power factor | Power factor: Pfa, Pfb, Pfc, Pf | √ | |
10 | phase position | Voltage/current: ∠Ua, ∠Ub, ∠Uc, ∠Ia, ∠Ib, ∠Ic | √ | |
11 | frequency | System frequency: f | √ | |
Electricity measurement | 12 | Active power | Split-phase and combined-phase bidirectional active energy | √ |
13 | Reactive power | Split-phase and combined-phase bidirectional reactive power | √ | |
14 | Apparent electric degree | Split-phase and close-phase are in electric energy. | √ | |
freeze | 15 | Minute freezing | Freeze once at 15: 00 on the hour, with a maximum of 5,000 frozen items. | √ |
16 | Daily freezing | Freeze once at 0 o'clock, with a maximum of 1000 frozen items. | √ | |
17 | Monthly freezing | Freeze once a month, with a maximum of 24 freezes. | √ | |
Power quality | 18 | Harmonic content | The harmonic content of three-phase voltage and current is 2~31 times. | √ |
19 | Harmonic distortion rate | Total, odd and even harmonic distortion rate | √ | |
20 | imbalance/ loss of balance | Unbalanced voltage and current | √ | |
incident record | 21 | SOE record | It has 500 SOE recording functions, including alarm power failure, etc., with time scale recording. | √ |
22 | Maximum record | The maximum and minimum values of relevant parameters (voltage, current, active power, reactive power, apparent power, power factor, frequency and demand) can be counted in real time, and recorded with time scales. | ○ | |
clock | 23 | clock | Accurate clock with hardware | √ |
communication interface | 24 | RS485 communication | Standard 1 RS485 communication, supporting MODBUS-RTU protocol; Support online upgrade program through RS485 interface. | √ |
25 | 4G communication | Support MQTT protocol | √ | |
Current transformer | 26 | External current transformer | Branch 300A~100mA transformer | √ |
Note: "√" marks this function as standard, and "○" indicates that this function is optional. |

5.About our service
* We could provide 7* 24-hour phone call after-sales service.
* We provide a 2-year guarantee time and will change the meter for you within 1 year if there's something wrong with the product. Except for natural disasters or man-made reasons.
* Recommend the most advanced application technology and management model in the industry to customers, and provide customers with detailed solutions.
6.Package and ship