Isg Single-Stage Single-Suction Vertical Pipeline Centrifugal Pump

Price $300.00 Compare
Min Order 1 Set
Shipping From Shanghai, China
Popularity 341 people viewed
Quantity
+-
 

Shanghai Liansheng Pump-Making Co., Ltd.

VIP   Audited Supplier 12 years
Profile Certified by SGS/BV
LISG
1 Year
1 Year
110m-150m
>400 L/min
Motor
Single-Stage Pump
High Pressure Pump
Single Suction Pump
Vertical Pump
Verticaljoint Surface Pump
Suction Centrifugal
Closed
Pump, Pumps, Condensate Pump, Slurry Pump, Circulating Pump, Clear Water
Lisg
100% Copper Wire
Blue
Single-Stage
Electric
LYSON or OEM
Standard Export Packing or According to Customers'
ISO9001/CE
Shanghai, China
8413709990
Product Description

Product Description

Products Name: ISG Single-stage Single-suction Vertical Pipeline Centrifugal pump


Conditions of use:

Note LISG is applicable to transport temperature does not exceed 80 CELSIUS water and similar to water.



The scope of performance parameter:

1. The flow of Q=2.5 ~ 400m3/h

2. Lift H=5 ~ 125m

3. Speed n=1480/2950r/min

4. Power P=0.55 ~ 135kW

5. Diameter of inlet Dna=40 ~ 80mm

6. Outlet diameter DNm=32 ~ 65mm
fault phenomenonfailure causeelimination methods
The manual is normal
Automatic transmission failure
1.No power supply or one or two phase power supply is needed
Check all phases of power supply and restore power supply

 
Water level is too low
Put water in the sink

 
The motor burned
Repair or replace the motor

 
1.Line is loose
Check wiring and tighten connectors

 
2.Frequency converter malfunctionCheck the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting.
3The frequency converter is damagedRepair or replace
4.Pressure switch damageRepair or replace
5The pressure transmitter is damagedRepair or replace
 6.Switch failureRepair or replace
Pump non - suction pressure gauge pointer to beat violentlyInsufficient water supply for perfusion, air leakage at the connection between pipeline and instrumentCheck pipeline and bottom valve, refill water diversion. Tighten air leakage

The pump consumes too much power

 

Too much flow, impeller wear

 
Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow








About LYSON

♦ ESTABLISHED IN THE SIXTIES


♦ THROUGH THE ISO9001:2015 DOMESTIC,

INTERNATIONAL QUALITY SYSTEM CERTIFICATION


♦ SILVER MEDAL WAS AWARDED AT THE NATIONAL CONFERENCE ON THE

APPLICATION OF SPARK CUP TECHNOLOGY


♦ WIN THE NATIONAL AWARD FOR EXCELLENCE IN CIVILIZATION COMPETITION 


♦ GET THE LC OF THE CHINESE GOVERNMENT
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA