Jdcf Series 66-230kv Oil-Immersed Cascade Inductive Voltage Transformer

Price $9999.00 Compare
Min Order 1 Piece
Shipping From Henan, China
Popularity 417 people viewed
Quantity
+-
 

Henan Energy Electric Equipment Co.,Ltd

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
JDCF
Electronic, Instrument, Position Sensor, Audio, Lighting
Voltage Transformer
Single
Outdoor
Protection, Measurement
Single Layer & Tightly Wound Type
Insulating Paper
Active Type
Cascade Type
Electromagnetic Type
66kv-230kv
Acceptable
Chinese, English, Russian
Negotiable
HEZC
Cartons or Others
As required
China
Product Description

 

Company Profile

Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.

Product Description
It is outdoor,single phase and oil immersed cascade inductive voltage transformer,
which is used for metering and relay protection of 66~230kV,50 or 60Hz system.


Standards:
IEC 61869-1;IEC 61869-3
GB 20840.1; GB 20840.3

Type description:

JDCF X (GY) (W1,W2,W3)
J: Voltage transformer

D: Single-phase
C: Cascade structure
F: Individual measuring and protective winding
X: Rated voltage (kV)
(GY): Applying to high altitude
(W1,W2,W3): Pollution level
Product Features

1.It is cascade structure,which the primary winding has two (220/230kV is four) grades,winding surrounded on core column of one (220/230kV is two)single phase two-limb  core.It  will be immersed in transformer oil after desiccating under vacuu. It has advantages of stable and reliable performance of insulation, rich operated experience, long service life and convenient maintenance.
2.Perfect fuidity performance of transformer oil is good for heat dissipation,it also has self restoring capacity for the failure of partial discharge caused by air bubble and dust.
3.It has three secondary winding,whose measuring and protective winding are separate.
4.Hermetically sealed stainless steel metallic bellows is installed on the top,which can protect the transformer oil and insulation paper from 
moisture and extend the 
life time,also there is a oil level gauge on the bellows for observing the change of oil volume.
5.There  is  a  multi  function  oil  drain  valve  on  the  base,which  makes  it  more convenient for oil sampling,draining and refilling.
6. All adopted insulation parts are environmental protection materials.
7.Secondary terminal board is made of epoxy casting,the seal performance is more reliable.
8.The base uses spray painting or hot galvanizing,which gives a high degree of corrosion  resistance.
9.Fasteners and nameplate are stainless steel.

Product Parameters
Rated primary voltage,kV66 or 69110 or 115132 or 138150220 or 230
Highest voltage for equipment,kV72.5123 or 126145170245 or 252
Rated frequency50or 60
Rated power frequency withstand voltage,kV140/160230275325460
Rated lightning impulse voltage,kV325/3505506507501050
Flashover distance,mm7801050130013002000
External insulation creepage distance,mmW1 :1450
W2:1820
W3:2250
W1:2520
W2:3150
W3:3910
W1:2900
W2:3630
W3:4500
W1:3400
W2:4250
W3:5270
W1:5040
W2:6300
V3:       0
Mechanical load,N12501250125012501250
Rated secondary voltage,kV0.115/√3wwor 0.115/0.11 /0.1
Secondary terminal markingla-1n2a-2nda-dn
Accuracy class0.20.53P
Rated output,VA100250300
150150300
150 300
Thermal limiting output,VA2000
Rated voltage factor1.2/continuous;1.9/8h(66kV)
1.2/continuous;1.5/30s(110~230kV)
Dielectric dissipation factor tgo,under 10kProduct  tgö<0.02;frame  tgö<0.05
 
Structure Diagram
NO.Name
1Bellows
2Oil level gauge
3Primary terminal
4Porcelain bushing
5Base
6Rating plate
7Earthing pads
8Oil drain valve
9Terminal box
10Terminal wire clamp
 
(Type)HhOil Wt (kg)Product Wt(kg)Installation dimensions (mm)
JDCF-66 or 69144011409055010×41
JDCF-110 or 1151770143014064010×41
JDCF-132 or 13820751735165120410×410
JDCF-15021901850190800410×41
 
Primary terminal (Stainless steel)                                  Primary terminal (Stainless steel)                                       Earthing pads                                 
TypeHhOil WtProduct WtDimension
JDCF-220or230300525902101350520×520
 
Service Environment

1. Ambient  temperature:-50ºC- +45ºC
2. Altitude:≤2000m(If above 2000m,the product will be customized according to user's request)
3. Pollution level: II, III, IV.