JY2000-AL
Electromagnetic Relay
Insulation Monitor
3
Dc
3
Medium Power Relay
Enclosed Relay
Electromagnetic Type
Miniature
Electric Parameter Relay
100-2000VDC
20
100-2000VDC
110*45*75
±3% ±3 V
OEM
Please Consult for Details
10*10cm
Zhejiang, China
Product Description

JY2000-AL series controls the insulation monitoring data by RS485 or CAN communication. Send a communication frame to turn on or off the insulation monitoring function. After the insulation monitoring function is turned on, the high-voltage grounding switch is closed, and the real-time measurement of insulation resistance is realized. After the insulation monitoring is powered on, it is turned off by default, and the host computer needs to actively send a communication frame to enable the insulation monitoring function. 

 

Feature

  1. Advanced Insulation Monitoring (High Voltage)
  2. Adaptive Ground Capacitance Detection
  3. Insulation resistance from 0Ω to 10MΩ
  4. DC voltage from 0V to 2000V
  5. RS485 Control and Data Reading
  6. LD1 & LD2 LED Indicators
  7. Fast Response within 1s
  8. Reliable Relay Output

Specification

 
ParameterValue
Power supply10-30VDC
Power supply capacity12V: 90mA
24V: 45mA
≤ 1.5W
DC voltage range100V~2000V
DC voltage
measurement accuracy
0-200VDC≤2V
200~2000VDC≤0.5%
Insulation resistance
measurement range
1KΩ~10MΩ
(DC System voltage:100V~2000V)
Insulation monitoring accuracy
((When :DC voltage:100V-2000V)
DC voltage: 100V~300V≤3kΩ+10%
DC voltage: 300V~2000V≤3kΩ+5%
CY range >0.3μF, Insulation resistance>1MΩ or CY range >1μF,>10%
Insulation resistance value
update time after turning on
After insulation monitoring is turned on, the time until the effective resistance value can be read for the first time0.7s~2s
Insulation resistance value
update time
Switch the insulation resistance until the module can read the switched insulation resistance value.0.5s~3s
Alarm relay
maximum switching voltage
250VAC/30VDC
Alarm relay
maximum switching current
3A
Alarm relay contact resistance<100mΩ
Alarm relay insulation resistance100MΩ
Off-line pressure test<2mA
StandardIEC 61851-23 (2014-03):2014-11
Humidity85%
Storage temperature- 55°C ~90°C
Operating temperature- 40°C ~75°C

Application