H250/RR/M9
≤±0.1%
Water, Wastewater
Dn15~Dn300
Tube/Flange
Variable Area Flow Meter
Liquid, Gas, Steam
Mechanics
DIN, CE
1%
10: 1
IP65, IP67
Krohne
Carton
Krohne standard
Germnay
9026100000
Product Description
Krohne Variable area flowmeter
1. Rugged all-metal design
2. Easy stocking of parts thanks to modular concept
3. Complete interchangeability of all components and assemblies
4. Linear display
5. Adjustable to any fluid through replaceable cam plate
6. Shot-stroke design/parts do not project beyond the flanges, no matter what position the float is in
7. Electrical or pneumatic remote data transmission system
8. Limit switches can be installed

1. Rugged all-metal design
2. Easy stocking of parts thanks to modular concept
3. Complete interchangeability of all components and assemblies
4. Linear display
5. Adjustable to any fluid through replaceable cam plate
6. Shot-stroke design/parts do not project beyond the flanges, no matter what position the float is in
7. Electrical or pneumatic remote data transmission system
8. Limit switches can be installed

Item | Krohne Variable area flowmeter |
Metering range(100% values) | Water(20° C) 6~15000 l/h Air (0.1013MPa 20° C) 0.05~4000 m 3 /h |
Rangeability | 10: 1 |
Accuracy class | 1.5 (Special version 1.0) |
Operating data | |
Max pressure | DN15~DN50 PN4.0MPa (Special versio 25MPa) DN80~DN100 PN1.6MPa (Special versio 16MPa) |
Temperature of fluid | -80° C~+220° C |
Ambient temperature | Max 120° C(Max. 60° C if signal output is electrical) |
Current output | 4-20mA (Optional) |
Viscosity of fluid | DN15: ≤ 5mPa. s(H15.1~H15.3) ≤ 30mPa. s(H15.4~H15.9) DN25: ≤ 250mPa. s DN50~DN150: ≤ 300mPa. s |
Connection Standard | Flange to DIN2501 or ANSI , Special Other standards on request |
Electaic | M20× 1.5, PG11, 1/2" NPT |
Owerall height | 250mm |
Protection category to DIN 40050 | IP65 |
Explosion Proof | ExiaIICT3~6 ExdIIBT4 |