LC1d258m7 4p Magnetic AC Contactor with 2 No and 2 Nc 220V/110V

Price $6.45 Compare
Min Order 100 Pieces
Shipping From Zhejiang, China
Popularity 201 people viewed
Quantity
+-
 

Wenzhou Juhong Electric Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
LC1D258M7
AC
4
1
380V
25A
Ac Contactors
DIN Rail
Silver
Black
Cooper
Cooper
Cooper
1n.O+1n.C
IEC
1 Year
1000000
100000
CNJUHO
50PCS/CTN
Zhejiang
8536490090
Product Description

1.Application:

JUHONG ELECTRIC IEC Contactor, D-Line Standard, Series: LC1D, 110/690 VAC, 300 VDC Coil, 40 A Maximum Load Current, 7.5/7.7 VA Coil, 4 Pole, 25 to 400 Hz Frequency, 3.2 W Wattage, Non-Reversing Contact, 2NO-2NC Contact Configuration, 1NO-1NC Auxiliary Contacts, 10/60 A at 600 VAC, 40/60 at 600 VAC Contact, Power Factor: 0.75 Inrush, 0.3 Hold-In, Screw Clamp Connection, 105/45/99 mm Size, Screw Clamp Terminal, IP2X Enclosure, 3600 cycles/hr Operating Cycles, -5 to 60/-40 to 70
Additional Description: SQD -LC1D258F7 TeSys 4P CTR 40A AC1 2NO 2NC 110VAC COIL +OPTIONS
Catalog Description: IEC contactor, TeSys Deca, nonreversing, 40A resistive, 4 pole, 2 NO and 2 NC, 110VAC 50/60Hz coil, open style

2.Main parameter
Product or Component TypeContactor
Device short nameLC1D258M7
Contactor applicationResistive load
Utilisation categoryAC-1
AC-3
AC-3e
AC-4
Poles description4P
[Ue] rated operational voltagePower circuit <= 690 V AC 25...400 Hz
[Ie] rated operational current32 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage220 V AC 50/60 Hz
Pole contact composition2 NO + 2 NC
Protective coverwith
[Ith] conventional free air thermal
current
10 A (at 60 °C) for signalling circuit 40 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity450 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand
current
240 A 40 °C - 10 s for power circuit 380 A 40 °C - 1 s for power circuit 50 A 40 °C - 10 min for power circuit 120 A 40 °C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit40 A 104 °F (40 °C) - 10 min for power circuit
84 A 104 °F (40 °C) - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit
Average impedance2 mOhm - Ith 40 A 50 Hz for power circuit
Power dissipation per pole3.2 W AC-1
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified
Overvoltage categoryIII
pollution degree3
[Uimp] rated impulse withstand voltage6 kV IEC 60947
safety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
mechanical durability15 Mcycles
electrical durability1.4 Mcycles 40 A AC-1 at Ue <= 440 V
Control circuit typeAC 50/60 Hz
coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3...0.6 Uc (-40…60 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))
70 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
7 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation2…3 W at 50/60 Hz
Operating time12...22 ms closing
4...19 ms opening
Maximum operating rate3600 cyc/h at 60 °C
tightening torqueControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 Power circuit: 1.8 N.m - on screw clamps terminals - with screwdriver flat Ø 6 mm Power circuit: 1.8 N.m - on screw clamps terminals - with screwdriver No 2 Power circuit: 1.8 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
auxiliary contact composition1 NO + 1 NC
auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
signalling circuit frequency25...400 Hz
minimum switching voltage17 V signalling circuit
minimum switching current5 mA signalling circuit
insulation resistance> 10 MOhm signalling circuit
non-overlap time1.5 ms on de-energisation between NC and NO contact;1.5 ms on energisation between NC and NO contact
Mounting SupportPlate;Rail
standardsCSA C22.2 No 14;EN 60947-4-1;EN 60947-5-1;IEC 60947-4-1;IEC 60947-5-1;UL 508;IEC 60335-1
Product CertificationsLROS (Lloyds register of shipping);CSA;UL;GOST;DNV;CCC;GL;BV;RINA;UKCA
IP degree of protectionIP20 front face IEC 60529
protective treatmentTHIEC 60068-2-30
climatic withstandIACS E10 exposure to damp heat;IEC 60947-1 Annex Q category D exposure to damp heat
permissible ambient air temperature around the device-40…140 °F (-40…60 °C);140…158 °F (60…70 °C) with derating
operating altitude0...9842.52 ft (0...3000 m)
fire resistance1562 °F (850 °C) IEC 60695-2-1
flame retardanceV1 conforming to UL 94
 
mechanical robustnessVibrations contactor open 2 Gn;5...300 Hz);Vibrations contactor closed 4 Gn;5...300 Hz);Shocks contactor open 10 Gn for 11 ms);Shocks contactor closed 15 Gn for 11 ms)
Height*Width*Depth3.6 in (91 mm)x1.8 in (45 mm)x3.9 in (99 mm)
Net Weight0.937 lb(US) (0.425 kg)
Category22355-CTR;TESYS D;OPEN;9-38A DC
Discount ScheduleI12
GTIN3389110353075
ReturnabilityYes
Country of originChina
Unit Type of Package 1PCE
Number of Units in Package 50PCS/CTN
Warranty18 months
 
 
3.We commit:
4.Office and working department:
5.Certificate:
6.shipping:
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA