Laboratory Highly Transparent Plain Slides/Single Frosted End Microscope Slides

Price $0.08 Compare
Min Order 1000 Pieces
Shipping From Shandong, China
Popularity 364 people viewed
Quantity
+-
 

Biologix Corporation

VIP   Audited Supplier 13 years
Profile Certified by SGS/BV
7101/7105
Polishing
Float Glass
Plain Slides/Single Frosted End
25.4 X 76.2
Clear
No
72 /Pack, 50 Packs/Case
3600/Case
BIOLOGIX
10 Pieces/Bag, 50bags/Case
CE, ISO, FDA
Changzhou, Jiangsu
7017900000
Product Description
Laboratory Highly Transparent Plain Slides/Single Frosted End Microscope Slides

Feature:
· Single Frosted End Rounded Corners Microscope Slides
· Material: galss, with excellent transparent
· Slide surface highly polished Ground edges prevent chipping and personal injury
· Slides with frosted area are convenient for labeling and storage
· Slides without frosted area have a larger usable surface area



Ordering Information
Cat #MaterialTypeSize (mm)SterileUnitTotal
7101GlassPlain Slides25.4 x 76.2No72 Slides/Pack, 50 Packs/Case3600 Slides/Case
7105GlassSingle Frosted End25.4 x 76.2No72 Slides/Pack, 50 Packs/Case3600 Slides/Case

1.What are the main factors that influence the maximum centrifugal acceleration force? 
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins. 
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower. 
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2. What are autoclaving guidelines of plastics? 
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA