Laminated Sheet Egpc202, Fr-4, Epgc203, Epgc204, G11 H Epoxy Glass Cloth Sheet

Price $5.00 Compare
Min Order 1000 KG
Shipping From Hainan, China
Popularity 414 people viewed
Quantity
+-
 

Hainan Fuwang Industrial Co., Ltd.

VIP   Audited Supplier 18 years
Profile Certified by SGS/BV
EPGC308, G11-H
Insulators, Motor, Switch Baseplate, Insulating Materials for Transformer
Natural, Green
Glass, Fiberglass Cloth and Epoxy Resin
H 180
0.4~150mm
1020*2040mm/1230*2470mm/1500*2500mm
H (180)Oc
Laminated
FW
1000kg/Pallet
IEC6089-3-2 EPGC308
China
Product Description
EPGC308/G11 H epoxy glass cloth sheet

1. COMPOSITION AND PRESENTATION
FUWANG G11 is a stratified insulator made from fibre glass fabric and epoxy resin.
At delivery time the presentation of the sheets is as follows:
- Maximum sizes: 1020 X 2040mm / 1230X2470mm/1500X2500mm
- Colour: Nature / Light Green / Brown
- Surfaces: Shining
- Thickness: From 0.4 mm
- On demand we can deliver strips or finished components.

2. PROPERTIES.
-Very low hygrometric susceptibility.
- Small losses at high frequency.
- Excellent mechanical properties when cold.
- Good dielectric properties
- Workable while cold up to 3 mm thick

3. APPLICATIONS.
Very convenient for equipment on high frequencies and in general for all elements put under high dynamic stresses with high resistance to fatigue

4. MAIN TECHNICAL CHARACTERISTICS / SHEETS FW G11
Details data sheet for your reference:

5. http://sinofuwang.en.made-in-china.com
 

ITEMS
CONDITIONSTEST METHODVALUES
Thermic endurancein transformer oil for 4 hoursIEC 60893-2-7.1180 O C ( H)
Specific weight20 O CIEC 60893-21.80 - 2.0 g/cm 3
Water absorption24 hIEC 60893-2-8.21.5 mm- 19 mg
Flexural strength
( perpendicular )
23 ±2 O CIEC 60893-2-5.1340 MPa min.
  180 O C170 MPa min.
Charpy impact strength
( parallel )
23±2 O CIEC 60893-2-5.4.233 KJ/m 2 min.
Izod impact strength
( parallel )
23 ±2 O CIEC 60893-2-5.4.335 KJ/m 2 min.
Electric strength
( perpendicular )
in transformer oil at 90±2 O CIEC 60893-2-6.13.0 mm  10.2KV/mm min.
Breakdown voltage
( parallel )
in transformer oil at 90 ±2 O CIEC 60893-2-6.1> 3.0mm  35 KV min.
Insulating resistances
after immersion in water
23 ±2 O CIEC 60893-2-6.35.0 X 10 10  min.
Message Type