CKFCRS-19II
45c
Common Heat Pump
Air-source
Circulating Heat
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
CE, ISO9001, CCC, SASO
Swimming Pool Heat Pump (Ckfcrs-19II)
28 Degree
35 Degree
Panasonic
R410A
KONNEN
Safe Export Packing
2000x2050x1980
China
8418612090
Product Description
KONNEN AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE:
* Panasonic compressor & R410a refrigerant, OR Copeland compressor and R417a refrigerant; |
* Stainless steel 304 for all fasteners, for side covers of evaporator; |
* Preservative oil for copper tubes and all important part of cabinet; |
* Chinese No.1 brand "ND" shell & tube heat exchanger; |
* Japan "Saginomiya" or "Sanhua" electronic expansion valve; |
* "Sanhua" 4-way valve; |
* "Schneider" AC contactor & Relay |
* LCD controller; |
* Delivery time: 20~25 days; |
* Payment term: T/T 30% in advance and T/T 70% before delivery; |
* Warranty time: 24 months after delivery. |
WE SUPPLY OEM SERVICE!
KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):

WHY US:

KONNEN NEW PROJECTS:

WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:

KONNEN HEAT PUMPS LOADING:

PARAMETERS TABLE:
S02H series(Swimming pool heat pump) SP-150301 | ||||||||||||||
SP03PS-E3 | SP05PS-E5 | SP03P-E3 | SP05P-E5 | SP07P-E5 | SP10P-C24 | SP14P-C24 | SP20P-C48 | SP24P-C48 | SP30P-C48 | SP36P-C96 | SP48P-C96 | |||
Rated heating capacity | kW | 14 | 24 | 14 | 24 | 32 | 48 | 66 | 95 | 115 | 145 | 170 | 230 | |
Rated input power | kW | 2.45 | 4.14 | 2.37 | 4.06 | 5.69 | 8.14 | 11.57 | 16.10 | 19.49 | 25.11 | 29.31 | 39.65 | |
Rated input current | A | 12.56 | 21.23 | 4.55 | 7.80 | 10.92 | 15.63 | 22.21 | 30.91 | 37.42 | 48.21 | 56.28 | 76.13 | |
COP | / | 5.71 | 5.80 | 5.91 | 5.91 | 5.62 | 5.90 | 5.70 | 5.90 | 5.90 | 5.77 | 5.80 | 5.80 | |
*Heating capacity | kW | 12 | 20 | 12 | 20 | 25 | 40 | 52 | 80 | 95 | 120 | 145 | 190 | |
*Input power | kW | 2.30 | 3.88 | 2.33 | 3.80 | 4.87 | 7.62 | 9.98 | 15.36 | 18.20 | 22.81 | 27.83 | 36.19 | |
*Input current | A | 11.81 | 19.92 | 4.47 | 7.30 | 9.36 | 14.63 | 19.16 | 29.48 | 34.94 | 43.80 | 53.44 | 69.49 | |
*COP | / | 5.21 | 5.15 | 5.15 | 5.26 | 5.13 | 5.25 | 5.21 | 5.21 | 5.22 | 5.26 | 5.21 | 5.25 | |
Maximum input power | kW | 3.19 | 5.38 | 3.08 | 5.28 | 7.40 | 10.58 | 15.04 | 20.93 | 25.34 | 32.64 | 38.10 | 51.55 | |
Maxmum input current | A | 16.33 | 27.60 | 5.92 | 10.13 | 14.20 | 20.32 | 28.88 | 40.19 | 48.65 | 62.67 | 73.16 | 98.97 | |
Rated hot water output temperature' | ºC | |||||||||||||
Maximum hot water output temperature | ºC | |||||||||||||
Power supply | 3N 380V/50Hz | |||||||||||||
Compressor | Type | Fully closed scroll type | ||||||||||||
Start mode | ||||||||||||||
Quantity | Set | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 3 | 3 | 4 | |
Water side heat exchanger | Type | |||||||||||||
Water flow | M3/h | 6.02 | 10.32 | 6.02 | 10.32 | 13.76 | 20.64 | 28.38 | 40.85 | 49.45 | 62.35 | 73.10 | 98.90 | |
Water pressure drop | KPa | ≤70 | ||||||||||||
Pipe size | Φ | Φ50 | Φ50 | Φ50 | Φ50 | Φ50 | Φ50 | Φ50 | Φ50 | Φ90 | Φ90 | Φ110 | Φ110 | |
Protections | ||||||||||||||
Noise | DB(A) | ≤55 | ≤63 | ≤55 | ≤63 | ≤63 | ≤65 | ≤68 | ≤70 | ≤72 | ≤73 | ≤74 | ≤78 | |
Unit dimensions | mm | 700×700×870 | 820×695×1060 | 700×700×870 | 820×695×1060 | 820×695×1060 | 1000×1000×1858 | 1000×1000×1858 | 1000×2050×1900 | 1000×2050×1900 | 1000×2050×1980 | 1000×2050×1980 | 2000×2050×1980 | |
Weight | KG | 100 | 160 | 100 | 160 | 165 | 335 | 365 | 600 | 660 | 840 | 860 | 1260 | |
Testing condition: 1. Ambient temp.(DB/WB):24ºC/19ºC, Water temp.(In/Out):26ºC/28ºC | ||||||||||||||
2. *Ambient temp.(DB/WB):15ºC/12ºC, Water temp.(In/Out):26ºC/28ºC | ||||||||||||||
The above parameters are based on Refrigearnt R410A, for parameters based on other refrigerant please contact us. | ||||||||||||||
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret. |