Shanghai Shineng Electrical Equipment Co., Ltd.

VIP   Audited Supplier 6 years
Profile Certified by SGS/BV
CZB5C
2.4kw
25-65A
100-400V
Lead-Acid Battery Charger
Electric Charger
Half-Bridge Charger
Lead Acid Battery Charger
100-400V
24V
0.64
11kw
100-380V/50Hz
2.4kw
100-400V
24V
24V 25A-65A
0.64
25A-65A
24X35X26cm
25kg
Power Frequency Charger
Shineng
Carton
24x35x26cm
Shanghai, China
8504409999
Product Description

Golf Cart  Lead Acid Battery Charger Single Phase 2kw 24V 25A65A  For Forklift Car CZB5C

1. Features
CZB5C Series Intelligent Charger is the organic combination of leakage transformer, technology of Silicon-controlled rectifier and Microcomputer Control. This device could optimize
Wsa+Pulse charging characteristic curve. As charge voltage of battery increases, charge current
decreases automatically.
Pulse charge would be performed before gas emissions or in late stage of recharge. On the premise
of guarantee adequate battery power, this device would lower greatly internal temperature and reduce
gas emissions of battery, prolong the life of battery effectively and raise the charging efficiency
eventually.
The whole product has simple structure, convenient operation, complete functions and high
efficiency
 
2.Applications
This device would be applicable to recharge of lead-acid batteries which could be used in
various electric vehicle such as power pallet trucks, fork-lift truck, lift truck, electronic tour bus.
3.Operating conditions
1) No higher than 1000 meters in altitude.
2) Ambient temperature between -10 and +40 degrees C.
3) Relative humidity not exceed 85% for conditions of ambient temperature around 20±5ºC.
4) Store in a place free from conductive dust & the risk of explosion.
5) Do not store in harmful atmosphere such as corrosive gas, insulating gas, steam.
6) Store in a place free from rain & snow.
7) Deviation from vertical shall be less than 5 degrees. Working situation without violent vibration and
striking.
 
Functions
1) There are various charging modes you can choose. This device would be suitable for different
uses of lead-acid battery charging. Before leaving the factory, different charging procedures
would be set up accordingly depending on types of batteries.3
--IWUIa+ Pulse multistage charging mode. Applicable to charging of ordinary lead-acid
batteries.
--IWUIa+EQU multistage charging mode. Applicable to equalization charging of
ordinary lead-acid batteries.
--IWIa multistage charging mode. Applicable to initial & desulfuration charging
of ordinary lead-acid batteries.
--IWUUa multistage charging mode. Applicable to charging of maintenance-free lead
acid batteries.
2)
The voltage and current double closed-loop framework is applied in the PID control technology.
This device can achieve dynamic tracking and automatic adjustment of charge parameters.
Charging procedure operates referring to corresponding recharge characteristic curve. Charge
current always meets the requirements of batteries for this parameter.
3)
High-intensity LED Lamp would indicate running state of this charging unit.
4)
Nixie tube would display charger parameters such as battery voltage, charge current &
capacity and recharged time. It could also show the code of charging curve and fault.
5)
Functions of automatic detection, delaying and soft-start.
6)
Function of temperature compensation. The voltage of tipping point of gas emission would
change with the temperature.
7)
Automatically measure the battery capacity and adjust the charging curve in real-time. On the
premise of guarantee adequate battery power, this device would lower greatly internal
temperature of battery, reduce gassing and shorten charging time at the same time.
8)
This device could also record data at the end of recharge for 30 times.
9)
Protection and alarm functions of open circuit, reverse connection, over load and short
circuit breakdown.
10) Protection and alarm functions of overheat fault of transformer and module.
11) During charging, once the connection cable falls off, this device would shut down
automatically.
12) Equalization charge could ensure capacity consistency of battery packs.
13) Function of automatic initial charge(This feature is only applicable to ordinary lead-acid
batteries).
--Initial charge must be performed for the first recharge of new batteries after addition of4
liquid electrolyte.
14) Function of desulfuration Charge(This feature is only applicable to ordinary lead-acid batteries.)
Battery aging, frequently idled or improperly maintained, these all would result in the formation of lead
sulfate crystal on electrode plates. In this condition, conventional charge would not be applicable any
more, desulfuration charge shall be used instead.
 
Single-phase AC(1NPE) or two-phase AC(2PE) input power
voltage. The code of the E, Frequency:50-60Hz.
 
SpecificationInput current

A
Input

power
kVA
Output

current
DCA
Battery

parameters
 Outline

dimension

  mm
Net
weight
kg
@220V@380VVAh
7.5-10h
E24V/20A3.4  0.8 20 24 115-160240×350×26021 
E24V25A4.3  0.9 25 24 145-200

240×350×2

60

21 
E24V/30A5.1  1.1 30 24 175-240240×350×26021 
E24V/35A6.0  1.3 35 24 205-280240×350×26021 
E24V40A6.8  1.5 40 24 230-320240×350×26024 
E24V45A7.7  1.7 45 24 260-360240×350×26024 
E24V50A8.5  1.9 50 24 290-400240×350×26026 
E24V55A9.4  2.1 55 24 320-440240×350×26026 
E24V65A11.1 6.4 2.4 65 24 375-520466×360×78340 
E24V/80A13.6 7.9 3.0 80 24 465-640466×360×78340 
E36V/30A7.7  1.7 30 36 175-240240×350×26024 
E36V/35A8.9  2.0 35 36 200-280240×350×26025 
E36V/40A10.2  2.3 40 36 230-320240×350×26025 
E48V/25A8.5  1.9 25 48 145-200240×350×26025 
E48V/30A10.2  2.3 30 48 175-240240×350×26028 
E48V/35A11.9  2.6 35 48 205-280240×350×26028 
E48V/45A15.3 8.9 3.4 45 48 260-360466×360×78342 
E48V55A18.8 10.9 4.1 55 48 320-440466×360×78346 
E48V65A22.2 12.8 4.9 65 48 375-520466×360×78350 
E48V80A27.3 15.8 6.0 80 48 465-640466×360×78356 
E72V/25A12.8  2.8 25 72 145-200280×430×26034 
E72V/30A15.3  3.4 30 72 175-240280×430×26034 
         
 
2)Three-phase AC(3/PE) input power voltage. The code of the D, Frequency: 50/60Hz
 
Specifcation Input current AInput

power

kVA

Outpu

t

curre

nt
neA

Battery

parameters
Outline

dimension

mm

Net
weig

ht

kg
@220V@380V@415VVAh

7.5-10h
D48V55A10.8 6.3 5.7 4.1 55 48 320-440466×360×78362 
D48V/65A12.8 7.4 6.8 4.9 65 48 375-520466×360×78365 
D48V80A15.7 9.1 8.3 6.0 80 48 465-640466×360×78368 
D48V/100A19.7 11.4 10.4 7.5 100 48 580-800526×360×88386 
D48V/120A23.6 13.7 12.5 9.0 120 48 700-960526×360×88395 
D80V65A21.3 12.3 11.3 8.1 65 80 375-520526×360×88387 
D80V70A23.0 13.3 12.2 8.8 70 80 405-560526×360×88387 
D80V80A26.2 15.2 13.9 10.0 80 80 465-640526×360×88389 
D80V/100A32.8 19.0 17.4 12.5 100 80 580-800526×360×88395 
D80V/120A39.4 22.8 20.9 15.0 120 80 700-960526×360×883107 
D96V/70A30.4 17.6  11.6 70 96 405-560680×450×119070 
D96V80A34.8 20.1  13.2 80 96 465-640680×450×119075 
D96V/90A39.1 22.6  14.9 90 96 520-720680×450×119085 
D96V/100A43.4 25.1  16.6 100 96 580-800680×450×119095 
D96V/125A54.3 31.4  20.7 125 96 725-1000680×450×1190120 
D96V/150A65.2 37.7  24.8 150 96 870-1200680×450×1190145 
D96V/170A73.8 42.8  28.1 170 96 985-1360680×450×1190165 
D120V/160A86.9 50.3  33.1 160 120 930-1280680×550×1400220 
D120V/180A97.7 56.6  37.2 180 120 1045-1440680×550×1400250 
D120V/200A108.0 62.9  41.4 200 120 1160-1600800×550×1400245 
D120V/220A119.0 69.2  45.5 220 120 1275-1760800×550×1400270 
D312V/20A28.2 16.3  10.8 20 312 115-160526×360×88389 
D324V/20A29.3 17.0  11.2 20 324 115-160526×360×88389 
 
 
 
 
 