power cable
Construction, Underground, Power Station, Engineering Construction
Low and Medium Voltage Cable
DC Cable
PVC or XLPE
PVC or PE
Round Wire
Bare Copper Wire
ISO, CCC, CE, RoHS
PVC Power Cable
Kingyear
Copper/Aluminum Conductor XLPE/PVC Power Cable
Philippines Power Cable Price
0.6/1kv Nyy-J/O Copper Core PVC Insulated Electric
0.6/1kv
GB12706, GB12666, IEC60502, IEC60331
90c
Plant Locaed at Cable Industrial Cluster District
Future Goods: 25-35 Days, Ready Stock: 7-10days
Philippine, Yemen, Vietnam, Indonesia
1-24hours
Free
KINGYEAR
Wooden Drum
2.5mm2~800mm2
Henan, China
8544492100
Product Description
Low Voltage Copper/Aluminum Conductor XLPE/PVC Insulated Swa Armoured Electrical Power Cable 0.6/1kv PVC POWER CABLE PRICE INQUIRY
2). DC resistance: conductor resistance of PVC power cable at 20ºC per kilometer is not more than the following values.
3). Voltage Test and Partial Discharge Test of the PVC power cable
Some Low Voltage Copper/Aluminum Conductor XLPE/PVC Insulated Swa Armoured Electrical Power Cable Applications shown as below:
price inquiry !!!

KINGYEAR Cable is one of the leading cable products production enterprise in China,our mainly products are electric wire,power cable, control cable,bare conductor(AAC/AAAC/ACSR),ABC overhead cable as below.


The Construction of Low Voltage Copper/Aluminum Conductor XLPE/PVC Insulated Swa Armoured Electrical Power Cable as below:

1 ..... solid (RE) or stranded (RM/SM) bare copper
2 ..... core insulation of polyvinylchloride (PVC)
3 ..... Inner sheath or wrapping tape
4 ..... outer sheath of polyvinylchloride (PVC), black
The technical data of Low Voltage Copper/Aluminum Conductor XLPE/PVC Insulated Swa Armoured Electrical Power Cable as below for reference:
1). Rated Voltage, No. of Core and Range of Sectional Area of this PVC power cable
Rated voltage (kv) Sectional area (mm2) No. of core | 1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 |
2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | - | 26/35 | |
1 Core | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | |
2 Core | 1.5-185 | 25-185 | |||||||
3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |
4 Core | 2.5-400 | 25-400 | |||||||
5 Core | 2.5-400 | 25-400 |
Nominal section area (mm2) | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 300 | 400 | 500 | 630 | 800 |
Copper core | 12.1 | 7.41 | 4.61 | 3.08 | 1.83 | 1.15 | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 | 0.099 | 0.0754 | 0.0601 | 0.047 | 0.0366 | 0.0283 | 0.0221 |
Aluminum core | 18.1 | 12.1 | 7.41 | 4.61 | 3.08 | 1.91 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 | 0.125 | 0.1 | 0.778 | 0.0605 | 0.0469 | 0.0367 |
Rate voltage Uo (kv) Item | 0.6/1 | 1.8/3 | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | |
Voltage | Test voltage | 3.5 | 6.5 | 12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 |
Test time | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
Partial discharge test | Test voltage | - | - | 6.2 | 10.4 | 15.1 | 20.8 | 31.1 | 36.3 | 45 |
Discharge capacity | - | - | 10 | 10 | 10 | 10 | 10 | 10 | 10 |