M510T-A
3 Years
500g (1.1 Lb)
up to 8
-2.000 to 20.000 pH
0.1, 0.01, 0.001pH
± 0.1 Mv or ± 0.03%
90 *255 *40 mm
OEM
-2000.00 to 2000.00 Mv
0.1, 0.01 Mv
Other
AC Adapter, 100-240V AC Input
Haicoer
Wood Box
Shanghai, China
Product Description
M510T-A Multi-parameter Analyzer

GENERAL FEATURES
Color High contrast LCD touchscreen, 4.3 inches. Intelligent operation system provides features including user management, calibration management, electrode management, method management, data management, Log Management and etc. Multi-reading feature allows auto-read, timed-read and continuous-read. Automatic/Manual temperature compensation ensures accurate results. Auto-hold feature senses and locks the measurement endpoint. Data Storage 1000 sets for each parameter (GLP-compliant). Data analysis feature helps user review, compare and recalculate results. Support for USB communication. Auto-power off feature effectively extends the battery service life. Reset feature automatically resumes all settings back to factory default options. IP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.
1-8 points calibration with Standard Recognition. Selectable pH buffer groups, including USA, NIST, DIN, GB, MERK, JIS. User-defined pH buffer or buffer group is supported. Automatic electrode diagnosis with pH slope and offset display
1-6 points calibration. Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, ppb, etc. Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode. Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.
1-5 points calibration automatically recognizes the standard solutions. Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor. Temperature compensation type (none, linear, pure water).

Large color touch screen.
Easy operation and comfortable experience.

Method management.
Various methods are built-in, available for methods customization.

Support for Bluetooth.

Assortment of accessories.
Model | M510T | |
Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
pH | Range | -2.000 to 20.000 pH |
Resolution | 0.1, 0.01, 0.001pH | |
Accuracy | ± 0.002 pH | |
Calibration Points | Up to 8 | |
Standard Customization | Yes | |
Calibration Reminder | Yes | |
Standard Recognition | USA, NIST, MERK, JIS, GB and DIN buffers | |
Slope Limit | Yes | |
mV/ORP | Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV | |
Accuracy | ± 0.1 mV or ± 0.03% | |
EH ORP Mode | Yes | |
ORP Calibration Points | 1 custom point (relative mV) | |
pX | Range | -2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX | |
Accuracy | ± 0.002 pX | |
Calibration Points | Up to 6 | |
ISE | Range | 1.000e-9 to 9.999e+9 |
Units | mol/L, mmol/L, g/L, mg/L, μ g/L, ppm, ppb | |
Resolution | Up to 4 significant digits | |
Accuracy | ± 0.3% | |
Calibration Points | Up to 8 | |
Conductivity | Range | 0.000 μ S/cm to 3000 mS/cm |
Resolution | 0.001 μ S/cm minimum, various with range selection | |
Accuracy | ± 0.5% FS | |
Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
Calibration Points | Up to 5 | |
Calibration Reminder | Yes | |
Standard Recognition | 10 μ S/cm, 84 μ S/cm, 500 μ S/cm, 1413 μ S/cm, 12.88mS/cm; 146.5 μ S/cm, 1408 μ S/cm, 12.85mS/cm, 111.3mS/cm | |
Resistivity | Range | 5.00 Ω ·cm~100.0 M Ω ·cm |
Resolution | 0.01 Ω ·cm minimum | |
Accuracy | ± 0.5% FS | |
TDS | Range | 0.000 ppm~1000 ppt |
Resolution | 0.001ppm minimum, changed with range | |
Accuracy | ± 0.5% FS | |
Salinity | Range | 0.0 ~ 80.0 ppt |
Resolution | 0.1ppt | |
Accuracy | ± 1ppt | |
Dissolved Oxygen Concentration | Sensor Type | Polarographic |
Range | 0.00 to 99.99 ppm | |
Resolution | 0.01 ppm | |
Accuracy | ± 0.10 ppm | |
Calibration Reminder | Yes | |
Calibration Points | Air-saturated water or zero point | |
Barometric Compensation | Yes | |
Manual Salinity Factor Correction | Yes | |
Saturation | Range | (0.0 to 600.0)% |
Resolution | 0.10% | |
Accuracy | ± 2.0% | |
Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Relative Accuracy | ± 0.1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Inputs | pH Electrode | BNC(Q9) |
DO with Temp. Probe | 4-pin aviation connector | |
Conductivity with Temp. Probe | 5-pin aviation connector | |
Outputs | USB | USB 2.0 flash memory device, PC, scanner |
Display options | Backlight | Yes |
Auto Shutdown | 300, 600, 1200, 1800, 3600 sec., off | |
IP Rating | IP65 | |
Date and Time | Yes | |
General | Power | Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output |
Dimensions | 90 × 255 × 40 mm | |
Weight | 500g (1.1 lb) |



ABOUT US

Q1What is your minimum order quantity? A1The minimum order quantity is very low, and the minimum order is one set. For customized projects, it depends on different requirements. Q2Do you offer guarantee for the products? A2Yes, we offer 1-2 years warranty to our products. Q3What is the delivrey time after an drder placed? A3Our standard delivery is 3-5days when we have stock.We will let you know the lead time according to your oder quantity in time. Q4What is the warranty? A4The free warranty is one year from the day of Commissioning qualified. Q5Can you tell me your main customers? A5Sorry we could not tell you except customer's permission. At the same time,your information also will be protected. Q6How can i get the after-service? A6We will be responsible for our products in the valid time.