Cu xlpe swa pvc power cable 4x95mm2 4x185mm2
Construction, Underground, Power Station, Engineering Construction
Low and Medium Voltage Cable
Low Voltage Cable
XLPE
PVC
Round Wire
Bare Copper Wire
ISO, CCC, CE, RoHS, VDE
Cu XLPE Swa PVC Power Cable 4X95mm2 4X185mm2
Kingyear
Low Voltage Power Cable
Cu XLPE Swa PVC Power Cable 4X95mm2 4X185mm2
4 Cores
XLPE
GB12706, GB12666, IEC60502, IEC60331
Black, Red, Yellow etc
Availaible
ISO9001/ISO14001
Plant Locaed at Cable Industrial Cluster District
Future Goods: 25-35 Days, Ready Stock: 7-10days
KINGYEAR
Wooden/Steel Drum or as Specified
Power cable 4x95mm2 4x185mm2
Henan, China
8544492100
Product Description
Main cable 4cx185mm2 cable 95 mm 4 core xlpe armoured cu xlpe swa pvc power cable 4x95mm2
PRICE INQUIRY
Similar Products:
KINGYEAR Cable is one of the leading cable products production enterprise in China,our mainly products are electric wire,power cable, control cable,bare conductor(AAC/AAAC/ACSR),ABC overhead cable as below.
2). DC resistance: conductor resistance at 20ºC per kilometer is not more than the following values.
3). Voltage Test and Partial Discharge Test.
Applications shown as below:
price inquiry !!!
PRICE INQUIRY
Similar Products:
KINGYEAR Cable is one of the leading cable products production enterprise in China,our mainly products are electric wire,power cable, control cable,bare conductor(AAC/AAAC/ACSR),ABC overhead cable as below.

Structure For Reference (Any of your customized can be accepted)
1 ..... solid (RE) or stranded (RM/SM) bare copper
2 ..... core insulation of polyvinylchloride (PVC)
3 ..... Inner sheath or wrapping tape
4 ..... outer sheath of polyvinylchloride (PVC), black
The technical data of Main cable 4cx185mm2 cable 95 mm 4 core xlpe armoured cu xlpe swa pvc power cable 4x95mm2 as below for reference:
1). Rated Voltage, No. of Core and Range of Sectional Area.
Rated voltage (kv) Sectional area (mm2) No. of core | 1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 |
2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | - | 26/35 | |
1 Core | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | |
2 Core | 1.5-185 | 25-185 | |||||||
3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |
4 Core | 2.5-400 | 25-400 | |||||||
5 Core | 2.5-400 | 25-400 |
Nominal section area (mm2) | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 300 | 400 | 500 | 630 | 800 |
Copper core | 12.1 | 7.41 | 4.61 | 3.08 | 1.83 | 1.15 | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 | 0.099 | 0.0754 | 0.0601 | 0.047 | 0.0366 | 0.0283 | 0.0221 |
Aluminum core | 18.1 | 12.1 | 7.41 | 4.61 | 3.08 | 1.91 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 | 0.125 | 0.1 | 0.778 | 0.0605 | 0.0469 | 0.0367 |
Rate voltage Uo (kv) Item | 0.6/1 | 1.8/3 | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | |
Voltage | Test voltage | 3.5 | 6.5 | 12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 |
Test time | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
Partial discharge test | Test voltage | - | - | 6.2 | 10.4 | 15.1 | 20.8 | 31.1 | 36.3 | 45 |
Discharge capacity | - | - | 10 | 10 | 10 | 10 | 10 | 10 | 10 |