WT-MP400
Car Type, Trailer Type, Marine, Land Use
Emergency Crew, Standby Unit, Common Units
AC Three Phase
Water Cooling
Fixed
Diesel Generator
400/230V 380/220V 440/220V 415/240V 480/277V
Single or Three Phase
50Hz/60Hz
1500rpm/1800rpm
23
Water Cooled
AVR Auto Voltage Regulator
Brushless, Self Exciting, 100% Copper
Class "H"
ISO9001, ISO14001, CE
Marathon
Plastic Seaworth Packing with Carton
500x800x1050MM
China
8501310000
Product Description


WT SERIES STAMFROD SIMILAR AC ALTERNATOR SPECIFICATION | |||||||||
AC Brushless atlernator,3Ph, 0.8PF, IP23, H insulation. | |||||||||
MODEL | 3Phase/50Hz/340-415V | 3Phase/60Hz/220-440V-480V | |||||||
Standby Power | Continuous power | Standby Power | Continuous power | ||||||
KVA | KW | KVA | KW | KVA | KW | KVA | KW | ||
WT184E | 22 | 18 | 20 | 16 | 25 | 21 | 23 | 18 | |
WT184F | 30 | 24 | 27 | 22 | 34 | 28 | 31 | 25 | |
WT184J | 44 | 35 | 40 | 32 | 51 | 40 | 46 | 37 | |
WT224D | 55 | 44 | 50 | 40 | 63 | 51 | 57 | 46 | |
WT224E | 70 | 56 | 63 | 50 | 80 | 64 | 72 | 57 | |
WT224F | 88 | 70 | 80 | 64 | 101 | 80 | 92 | 74 | |
WT274C | 110 | 88 | 100 | 80 | 126 | 101 | 115 | 92 | |
WT274D | 125 | 100 | 113 | 90 | 144 | 115 | 130 | 103 | |
WT274E | 150 | 120 | 137.5 | 110 | 172 | 138 | 158 | 126 | |
WT274F | 165 | 132 | 150 | 120 | 190 | 152 | 172 | 138 | |
WT274G | 200 | 160 | 180 | 144 | 230 | 184 | 207 | 166 | |
WT274H | 220 | 176 | 200 | 160 | 253 | 202 | 230 | 184 | |
WT274J | 250 | 200 | 230 | 184 | 287 | 230 | 264 | 211 | |
WT274K | 275 | 220 | 250 | 200 | 316 | 253 | 287 | 230 | |
WT444D | 300 | 240 | 275 | 220 | 345 | 276 | 316 | 253 | |
WT444E | 350 | 280 | 313 | 250 | 402 | 322 | 360 | 287 | |
WT444F | 413 | 330 | 375 | 300 | 475 | 379 | 431 | 345 | |
WT544C | 500 | 400 | 450 | 360 | 575 | 460 | 517 | 414 | |
WT544D | 550 | 440 | 500 | 400 | 632 | 506 | 575 | 460 | |
WT544E | 650 | 520 | 575 | 460 | 747 | 598 | 661 | 529 | |
WT544F | 715 | 570 | 650 | 520 | 822 | 655 | 747 | 598 | |
WT544G | 825 | 660 | 750 | 600 | 948 | 759 | 862 | 690 | |
WT634C | 880 | 704 | 800 | 640 | 1011 | 809 | 920 | 736 | |
WT634D | 1000 | 800 | 910 | 728 | 1149 | 920 | 1046 | 837 | |
WT634E | 1100 | 880 | 1000 | 800 | 1264 | 1011 | 1149 | 920 | |
WT634F | 1250 | 1000 | 1100 | 900 | 1437 | 1149 | 1264 | 1034 | |
WT634G | 1375 | 1100 | 1250 | 1000 | 1580 | 1264 | 1437 | 1149 | |
WT634H | 1512 | 1210 | 1375 | 1100 | 1738 | 1391 | 1580 | 1264 | |
WT634J | 1650 | 1320 | 1500 | 1200 | 1897 | 1517 | 1724 | 1379 | |
WT734C | 1875 | 1500 | 1700 | 1360 | 2155 | 1724 | 1954 | 1563 | |
WT734D | 2063 | 1650 | 1875 | 1500 | 2371 | 1897 | 2155 | 1724 | |
WT734E | 2250 | 1800 | 2000 | 1600 | 2586 | 2069 | 2299 | 1839 | |
WT734H | 2500 | 2000 | 2250 | 1800 | 2874 | 2299 | 2586 | 2069 |
SPECIFICATIONS & OPTIONS | ||||
STANDARDS | ||||
WINTPOWER industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359. Other standards and certifications can be considered on request. | ||||
AUTO VOLTAGE REGULATORS | ||||
SX460 AVR - STANDARD | ||||
With this self excited control system the main stator supplies power via the Automatic Voltage Regulator (AVR) to the exciter stator. The high efficiency semiconductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three phase full wave bridge rectifier. This rectifier is protected by a surge suppressor against surges caused, for example, by short circuit. | ||||
AS440 AVR | ||||
With this self-excited system the main stator provides power via the AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by a surge suppressor against surges caused, for example, by short circuit or out-of-phase paralleling. The AS440 will support a range of electronic accessories, including a 'droop' Current Transformer (CT) to permit parallel operation with other ac generators. | ||||
MX341 AVR | ||||
This sophisticated AVR is incorporated into the WINTPOWER Permanent Magnet Generator (PMG) control system. The PMG provides power via the AVR to the main exciter, giving a source of constant excitation power independent of generator output. The main exciter output is then fed to the main rotor, through a full wave bridge, protected by a surge suppressor. The AVR has in-built protection against sustained over-excitation, caused by internal or external faults. This de-excites the machine after a minimum of 5 seconds. An engine relief load acceptance feature can enable full load to be applied to the generator in a single step. If three-phase sensing is required with the PMG system the MX321 AVR must be used. We recommend three-phase sensing for applications with greatly unbalanced or highly non-linear loads. | ||||
MX321 AVR | ||||
The most sophisticated of all our AVRs combines all the features of the MX341 with, additionally, three-phase rms sensing, for improved regulation and performance. Over voltage protection is built-in and short circuit current level adjustments is an optional facility. | ||||
WINDINGS & ELECTRICAL PERFORMANCE | ||||
All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th …) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion. | ||||
TERMINALS & TERMINAL BOX | ||||
Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access. | ||||
SHAFT & KEYS | ||||
All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. | ||||
INSULATION/IMPREGNATION | ||||
The insulation system is class 'H'. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. | ||||
QUALITY ASSURANCE | ||||
Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. | ||||
The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%. | ||||
NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing typical of product range. | ||||





ΔFAQ
What's your power range of Generators?
Answer: We can offer the range from 5kva~3000kva.
2.What's your delivery time?
Answer: Generally,we can delivery in 15-35 days after confirmation of order.
3.What's your payment?
Answer: We can accept T/T 30% in advance, and the balance 70% shall be paid before shipment
or L/C at sight. But based on some special project and special order,we can do something support on payment item.
4.What's your warranty?
One year or 1000 hours (according to whichever reach first) from Ex-Factory date
5.What's your MOQ?
Answer:We accept power generator MOQ is 1 set .
WINTPOWER Service System
Customer-focused traditional service better and better service levels worldwide-network Service
Concepts:Ensure that customers at ease using for WINTPOWER Products Serving the customers, WINTPOWER gains trust .Work together with Customers During the service period, WINTPOWER do best firstly and protects customers' interests.
In case of failure to use the generator, WINTPOWER help customer until they know how to use
WINTPOWER Service Principles
Customer foremost and honesty as foundation. Serving the customers heart and soul at all levels 24 hours each day.
Δ Factory Inspection: the test items before delivery are mainly as follows:
1.Each gensets shall be put into commission and loading more than 1 hours totally. They are tested on idle
load, testing range 25% 50% 75% 100% 110% 75% 50% 25% 0%
2.The noise level is tested by requested
3.All of the meters on the control panel shall be tested
The appearance of the genset and all of the label and nameplate shall be checked