Meatrol Me337 Power Analyzer Rogowski Measuring Instrument Panel Meter

Price $35.00 Compare
Min Order 1 Piece
Shipping From Shanghai, China
Popularity 280 people viewed
Quantity
+-
 

ROGOWSKI TECHNOLOGY (SHANGHAI) CO., LTD.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
ME337
1 Year
1 Year
Digital
Panel Mounting
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter, Power Analyzer
Three-phase Four-wire
Electronic Meter
Terminal Type or RJ45 Port
Cts and Rogowski Coil
Energy Meter
RoHS, ISO, CE
Customized
External Cts, External Rogowski Coil
Alarm, 6 Tariff
95~265VAC, 12V DC, 24V DC
3pH4w 3pH3w 1pH2w (L-N) 1pH2w(L-L) 1pH3w(L-L-N)
Power Analysis, Tariff Meter
8K Samples Per Second
50th Max
2400BPS~115200BPS
Class 0.5s
Modbus RTU, RS485 Port
Adjustable From 0.1A to 9999A
0-600VAC
50/60Hz
LCD Display
MEATROL
Poly Bag and Stand Export Carton
96*96 *45mm
China
9030331000
Product Description
World-famous manufacturer
Three major production bases in Shanghai, Chongqing, and Zhejiang
Looking forward to in-depth communications, project cooperation, and exclusive agency
ME337
Three phase multi-function Smart meter 


ME337 panel type three-phase multi-function power meter, connecting to external Rogowski coil or voltage type CTs, realize the test without removing the wire, simplify the test steps, and save construction costs. ME337 supports three-phase and single-phase systems; It can measure multiple electrical parameters such as voltage, current, power factor, harmonics, power, and energy of A, B and C phases.
ME337 is equipped with RS485 communication interface, through the standard Modbus-RTU protocol, can be compatible with various configuration systems, the front-end collected electrical parameters real-time transmission to the system data center.

 
1.  Product Features
*Fast installation
    Product size is standard 96 panel type
    Installation method is a snap on type, without screws
*Support multiple current transformer connections
    The ME337N series supports a new type of current transformer - rogowski coil direct connection, without the need for an external integrator 
    The ME337N series supports voltage output type current transformer connection simultaneously
    The ME337C series supports direct current connection, with a maximum connection current of 7A
*Support multiple power grid systems
    Supports three-phase four wire, three-phase three wire, one phase three phase, and single-phase systems
*Multiple power supply options available
    Available in 220VAC, 24VDC and 12VDC power supplies
*Support voltage and current harmonic measurement
    Supports voltage, current, fractional harmonics, up to 50 measurements
    Support voltage and current harmonic distortion and harmonic value measurement
    Support voltage and current total harmonic distortion measurement
*More features
    Support 6 rate tariff energy, support RTC switching or manual switching
    Support demand measurement
    Support alarm setting
    Support current transformer orientation modification
    Support current channel modification

           Model naming
 

 2.  Features overview
 
Overview
TypePanel type
ModelME337
Current sensor typeME337NME337C
Rogowski coil, voltage output type CTCurrent type transformer
CharacteristicSupport direct access to Rogowski coilsDirect current connection
AdvantageSuitable for wide current range, without disassembling wires for measurement
Wire system3P4W 4CT,3P4W 3CT,3P3W 3CT,3P3W 2CT,1P3W,1P2W
ApplicationPower analysis, energy measurement
Display screenLCD display
Weight259g
SizeL*W*D:96*96 *45mm
ColorWhite and black
Current measurement
Channel input rangeME337NME337C
0-900mVAC peak,636mV RMS0-7A AC
Measuring rangeRogowski coilsVoltage output type CT0-7A AC
50mV/kA@50Hz(0-12000A),@60Hz(0-10000A)
85mV/kA@50Hz(0-7000A),@60Hz(0-6000A)
100mV/kA@50Hz(0-6000A),@60Hz(0-5000A)...
Varies with instrument transformer parameters
Voltage measurement
Measuring range0~600VAC Phase voltage
Maximum measurement720VAC Phase voltage
Digital signal
Relay output1 electromagnetic relay output, contact capacity: 3A 30V DC, 3A 250V AC
Digital input2 dry contact inputs, optocoupler isolated (5kVrms)
Communication
RS485One RS485 communication interface, interface type: two-wire half-duplex
Communication rate: 2400bps~115200bps
Specification: Modbus-RTU
Power supply
PowerME337XX2ME337XX3ME337XX4
95~265VAC/110~370VDC,45~60Hz18-36VDC9-18VDC
Maximum power consumption3.5VA

3.  Data display
 
Instantaneous value
Phase voltageU1,U2,U3,AVG
Line voltageU12,U23,U31,AVG
CurrentI1,I2,I3,AVG,In
Grid frequencyF1,F2,F3,∑ (Total)
Power factor PFPF1,PF2,PF3,∑(Total)
Displacement Power factor DPFDPF1,DPF2,DPF3,∑(Total)
Active powerP1,P2,P3,∑(Total)
Reactive powerQ1,Q2,Q3,∑(Total)
Apparent powerS1,S2,S3,∑(Total)
Energy
Active Energy ImportEP1,EP2,EP3,∑(Total)
When the total Energy reaches 1.0 x 10^9 kWh, the energy of each phase will automatically clear to zero
Active Energy ExportEP1,EP2,EP3,∑(Total)
When the total Energy reaches 1.0 x 10^9 kWh, the energy of each phase will automatically clear to zero
Reactive Energy ImportEQ1,EQ2,EQ3,∑(Total)
When the total Energy reaches 1.0 x 10^9 kVARh, the energy of each phase will automatically clear to zero
Reactive Energy ExportEQ1,EQ2,EQ3,∑(Total)
When the total Energy reaches 1.0 x 10^9 kVARh, the energy of each phase will automatically clear to zero
Apparent EnergyES1,ES2,ES3,∑(Total)
When the total Energy reaches 1.0 x 10^9 kVAh, the energy of each phase will automatically clear to zero
Tariff EnergyET1,ET2, ET3,ET4, ET5,ET6
When Energy reaches 1.0 x 10^9 kWh, Energy automatically clears to zero
Harmonics
Voltage harmonic percentageTotal harmonics (U1, U2, U3), odd total harmonics (U1, U2, U3), even total harmonics (U1, U2, U3)
Fractional harmonics of order 1-50 (U1, U2, U3)
Current harmonic percentageTotal harmonics (I1, I2, I3), odd total harmonics (I1, I2, I3), even total harmonics (I1, I2, I3), K factor (I1, I2, I3)
Fractional harmonics of order 1-50 (I1, I2, I3)
Voltage harmonic valueTotal harmonics (U1, U2, U3)
Fractional harmonics of order 1-50 (U1, U2, U3)
Current harmonic valueTotal harmonics (U1, U2, U3)
Fractional harmonics of order 1-50 (U1, U2, U3)
Phase diagram
Phase sequenceVoltage, current
Voltage angleU1,U2,U3
Current angleI1,I2,I3
Voltage and current angleUI1,UI2,UI3
Demand
DemandTotal Active power, Total Reactive power, Total Apparent power
Total Active power demand maxMaximum demand and time
Total Reactive power demand maxMaximum demand and time
Total Apparent power demand maxMaximum demand and time
Unbalance
Voltage unbalanceNegative order, zero order
Current unbalanceNegative order, zero order
Max.&Min.
Phase voltagePhases and averages
Line voltagePhases and averages
CurrentPhases and averages
Active powerPhases and averages
Reactive powerPhases and averages
Apparent powerPhases and averages

4.  Accuracy and certification
 
Measuring accuracy
current measurement accuracy0.1%+Accuracy of current sensor 
Voltage measurement accuracy±0.2%(60V~600V AC)
Grid frequency±0.01%(45~65Hz)
Power factor±0.005
Active and apparent powerIEC62053-22 level 0.5S
Reactive powerIEC62053-21 level 1S
Active energyIEC62053-22 level 0.5S
Reactive energyIEC62053-21 level 1S
Environment condition
Operating temperature-20ºC~+70ºC
Storage temperature-40ºC~+85ºC
Humidity range5~95% RH, 50ºC(non-condensing)
Class of pollution2
Over voltage capabilityCAT III 1000V, It is suitable for distribution system below 277 / 480VAC
Insulation strengthIEC61010-1
Altitude3000m Max
Antipollution levelIP20(Meet the standard of  IEC 60629)
Quality guarantee period12 months
 

Current sensors for reference, more options could be offered.
 
RATED CURRENTCURRENT SENSORDESCRIPTION
5ASCT-10Diameter 10mm
50ASCT-16Diameter 16mm
100AMRC-16Diameter 16mm
(Rogowski coil)
300AMRC-24Diameter 24mm
(Rogowski coil)
600AMRC-36Diameter 36mm
(Rogowski coil)
1kANRC-100Diameter 100mm
(Rogowski coil)
3kANRC-150Diameter 150mm
(Rogowski coil)
6kANRC-200Diameter 200mm
(Rogowski coil)
 







Message Type