UN3000
Hfnc Machine
Respiratory Therapy
Oxygen Therapy
Without LCD Display
Adult
Oxygen Therapy
Hospital (ICU/Ricu)
Single or Dual
0.1-1, 1-10, 2-18, 1-15, 6-60, 7-70, 10-80, 10-120
21%-100%
+/-3%
When Gas Supply Pressure Difference > 0.1 MPa
>57 dB(a)
3lpm
UN Medical
Carton
63*62*11.5cm&55.5*38.5*48.5cm
China
9019200090
Product Description
UN-Medical Air Oxygen Blender Double or Single
Model:UN3000

Adult / Infant HFNC Machine:

Specification:
Configuration and Package:



Multiple Choices:


Applications and Custom Choices:
HFNC Machine without Medical Air Compressor(Above)
HFNC Machine with Medical Air Compressor(Below)

Exhibitions Image

Factory Image


Shipment and payment
For the order which less than 20units, more of the customers choose the shipment by Express Courier or by Air Cargo.
Our normal Lead Time is within 5-7working days after payment.
Contact us: Yuki. Cai

Model:UN3000

Adult / Infant HFNC Machine:
·Medical device treatment: In addition to drug treatment, respiratory support treatments relying on medical devices, such as oxygen therapy, invasive mechanical ventilation, extracorporeal membrane oxygenation (ECMO), and circulatory support are of much helpful to those the most serious cases of pneumonia. It also plays an important role in the treatment of critically ill patients. It is time to introduce our high flow oxygen blender for replacement. It is very helpful for the early infection cases and the recovery patients from critical stages.
·High Flow Nasal Cannula(HFNC) oxygen therapy is a form of non -invasive respiratory support, which comprises an air oxygen blender, an active humidifier, a single heated circuit and a nasal cannula. It delivers adequately heated and humidified medical gas up to 10-60L/min, and is considered to have a number of physiological effects: reduction of anatomical dead space, PEEP effect, constant fraction of inspired oxygen and good humidification. It is widely used in RICU and ICU.

Specification:
Adjustment Method of Oxygen Concentration | Merchanical |
FiO2 | 21%-100% |
Flow | 2-18LPM;1-10LPM and 10-120LPM |
Pressure of gas source | Air/Oxygen @ 0.3-0.4 Mpa |
Blender Alarm | When gas supply pressure difference > 0.1 Mpa |
Blender Alarm Noise | >57 dB(A) |
Accuracy of FiO2 | 3% |
Humidifier Supply Voltage/Frequency | 220V/ 110V 50/60Hz |
Humidifier Temperature monitoring | 0-75ºC |
Humidifier Heater Plate Over-temperature Cut Off | 95±5ºC |
Heater Wire(Max.) | 22V-,2.73A, 60W, 50/60Hz |
Humidifier Temperature control settings | Heated wire mode(mode indicator lighted) |
Temperature grade(with indicator status) Continuous flow range Delivered patient temperature P1 (·○○) 5L/min-60L/min 25-29ºC P2 (··○) 5L/min-60L/min 29-35ºC P3 (···) 5L/min-60L/min 35-39ºC | |
Non-heated wire mode(It is not recommended in adult HFNC. Operate manual of humidifier show details) |
Configuration and Package:



Multiple Choices:


Applications and Custom Choices:
HFNC Machine without Medical Air Compressor(Above)
HFNC Machine with Medical Air Compressor(Below)

Exhibitions Image

Factory Image


Shipment and payment
For the order which less than 20units, more of the customers choose the shipment by Express Courier or by Air Cargo.
Our normal Lead Time is within 5-7working days after payment.
Contact us: Yuki. Cai