DNSMAL30
IVD Reagent
Test Strips & Test Tube
Without Ethylene Oxide Sterilization
Two Years
Adult
Plastic and Paper
OEM
1PCS/Foil Pouch, 40 PCS/Valve Bag, 2000 PCS/Carton
Strip/Cassette
by Air or by Sea
Strip: 2.5mm, 3.0mm; Cassette: 3.0mm, 4.0mm
Diagnos
Carton
Jiangsu, China
3822001000
Product Description
Medical Diagnostic Malaria Cassette Antigen pv pf pan Rapid Test Kit
The one step Cassette Style Malaria P.f. test is a rapid test based on the principle of immunoassay combined with conjugated colloid gold technology. The Malaria P.f. test((Whole Blood) is a diagnostic device to detect the presence of the P.f. antigen in whole blood |
Details of products
Model Number: | DNSMAL30 | Brand Name: | Diagnos and OEM |
Power Source: | Manual | After-sale Service: | Online Technical Support |
Specimen: | Urine /Serum | Format: | Cassette |
Accuracy: | 99.5% | Spencimen: | Whole blood |
Quality Certification: | FSC/CE/ISO13485 | Warranty: | 2 years |
Product Information



Test Procedure
Allow the test kit, specimen, buffer, and/or controls to equilibrate to room temperature (15-30°C) prior to testing.
2. Remove the test kit from the foil pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
3. Place the test device on a clean and level surface. Transfer the specimen by a Disposable Specimen Dropper(or a Pipette):
To use a Hold the dropper vertically, draw the specimen up to the Fill Line as shown in illustration below(approximately 10 µL). Transfer the specimen to the specimen well (S) of the test device, then add 2 full drops of buffer (approximately 100 µL) and start the timer. Avoid trapping air bubbles in the specimen well (S).
4. Wait for the red line(s) to appear. The result should be read at 15 minutes. Do not interpret the result after 20 minutes.

* POSITIVE*: In addition to a pink colored control (C) band, a Distinct pink colored band will also appear in the test (T) region.
*Note(Weak Positive): Colored band appearing in control Region (C) together with a faint colored band in Test Region (T).
* Negative: Only one colored band appears on the control (C) region. No apparent band on the test (T) region.
Invalid: A total absence of color in both regions is an indication of procedure error and/or the test reagent has deteriorated.
* Negative: Only one colored band appears on the control (C) region. No apparent band on the test (T) region.
Invalid: A total absence of color in both regions is an indication of procedure error and/or the test reagent has deteriorated.

Storage and Stability

Packing & Delivery

1. Strip:1 test and 1 decissant in a single pouch,100pcs in a polybag or medium box,5000pcs packed one carton;
Cassette:1 test and 1 decissant in a single pouch,40pcs in a polybag or medium box,2000pcs packed one carton.
2. Shipping methods: By sea or by air.
Company Profile
Our Advantages:

FAQ

Contact Us
Promise: Great Service is our mission, high quality is our obligation! As we strongly believe that QUALITY and SINCERE are very important among business trip !
Welcome to enquiry!
