MC-0724
Catheter
High Quality PC Material, PU Material
Ethylene Oxide Sterilization
Five
Adult
with or Without Logo Printing
Free for 2PCS
MCR/OEM
24h/72h/Child/Adult
Closed Suction Catheter
ISO13485/ FDA
Class II
1PCS/Pouch, 10 Pouches/Box, 10 Boxes/Carton
30days
Transparent
MCR
Carton
10fr/12fr/14fr/16fr
China
901839
Product Description
Closed Suction Catheter (Y-Piece) 72 hours for Adult, Push Switch & Luer Lock Type, Endotracheal/ Tracheostomy Closed suction Catheter

-It is designed with a protective sleeve to isolate the germs inside and help caregivers avoid cross-infection.
-Simultaneous ventilation design will allow the patients' comfort of suctioning without stopping the air ventilation.
-Push switch and Luer lock. This design can keep breathing and isolate the turbulent cleaning chamber and prevent spray back, which reduces the risk of VAP (ventilator-associated pneumonia) for ventilated patients.
Feature
- Continuous Breathing
Simultaneous ventilation
- Soft Blue Suction Tip
This design reduces damage to the patient while suctioning.
After returning the catheter, the tip of the tube is easier for irrigational cleaning.
- Double Swivel Connector
15mm connector of Double Swivel
- Disconnecting Wedge
Designed to equip the wedge with both disconnecting and clipping functions
- For Endotracheal Tube and Tracheostomy Tube
Designed for endotracheal and tracheostomy tube using
Tubes with different length are available
- Prevent Cross Infection
Designed with a protective sleeve to isolate the bacteria inside and help caregivers avoid cross-infection.

Product Data Sheet
-Closed Suction Catheter Standard Form

We can produce the closed suction catheter according to customers' requirements!!!
-Instructions for Use
*Set up Procedure
1. Inspect the product before use. Do not use it if the package is not intact.
2. Open the sealed package and remove the product.
3. Connect the Endotracheal Tube/Tracheostomy Tube to the Revolvable adapter.
4. Connect ventilator tube to the Revolvable Ventilator Connector.
5. Attach the date label to the color ring.
6. Before suctioning commences, ensure that the cap of the MDI Port and Irrigation Port is closed.
7. Before suctioning: please ensure that the on-off valve is in the open position. Simply slide the on-off valve to a position which allows the catheter to enter the Endotracheal tube/Tracheostomy tube.
*Suctioning Procedure
Caution-always use the recommended vacuum levels./Consider length of suctioning time
1. Grip the three-way adaptor in one hand and use the other hand to feed the suction catheter into the Endotracheal tube/Tracheostomy tube to the required depth.
Depth markers can be visible through the protective cover for your guidance.
2. Once the suction catheter is in the desired position /depth depress the vacuum control valve to begin suctioning.
3. Remove the suction catheter until the protective sleeve is straight.
4. Repeat steps1-3 as necessary.