DR850X
Customized
CE, ISO13485
Large
1ms~6300 Ms
Venu1717X
40kv-150kv
Manual Control
10mA-400mA
32kw
220VAC,±10%,50Hz
Aec Ionization Chamber Power Supply:+/-15V
DELL
Support Dicom 3.0 and Pacs Network in Hospital
Can Be Connect with Laser Printer to Print Film
40kv~125kv
DAWEI
Export Standard
250*140*95CM
China
9022140090
Product Description
RD-850X Digital X-ray Radiography System(DR)

3, Product characteristics and technical parameters
No. | Component | Performance parameter |
1 | Medical diagnostic X-ray high-frequency high-voltage generator | Output Power: 50kW |
Input Voltage: 220VAC,±10%,50Hz | ||
Inverter Frequency: 25kHz,±10% | ||
kV range: 40 KV~150KV | ||
mA range: 10 mA~630 mA | ||
ms range: 1ms~6300 ms | ||
mAs range: 0.1mAs~200mAs | ||
Tech mode: kV-mA(AEC);kV-mAs;kV-mA-ms | ||
APR: 2000 | ||
AEC(Optional): AEC Ionization chamber power supply:+/-15V Minimum exposure time:5ms | ||
Auxiliary power supply: +24V DC 2A;24V AC 8A | ||
Communication Interface: RS-232 | ||
2 | X-ray Tube Assembly | X-ray Tube Voltage Range: 50kV~150kV |
Nominal Focal Spot Value: 0.6mm(Small Focus)/1.2mm(Large Focus) | ||
Nominal Anode Input Power: 20kW(Small Focus)/50kW(Large Focus) | ||
Anode Heat Content: 300KHu | ||
3 | Flat Panel Detector | Image Sensor: a-Si (Amorphous Silicon) TFT |
Scintillator: CsI:Tl | ||
Effective Array: 3072 ×3072 | ||
Pixel Size: 139 um | ||
Effective Area (H x V): 427mm×427mm | ||
Preview Time: 3s | ||
Imaging Time: 5s | ||
Spatial Resolution: 3.6 lp/mm | ||
AD Conversion: 16 bit | ||
Data Interface: Gigabit Ethernet | ||
Trigger Mode: AED(optional)/Software/Prep | ||
Dimension (L × W × H): 460mm×460mm×15mm | ||
Weight: 4kg | ||
Power Consumption: 20W |

Ultra-wide range of millisecond-level control, with three exposure modes of kV-mA, kV-mAs, and kV-mA-ms.
Fault self diagnosis, accurate positioning error, convenient maintenance, modular design.
Industry leading automatic tube calibration function, perfect control tube current accuracy.
Flat panel detector

The high-performance cesium iodide process achieves high-quality images while reducing exposure dose.
139μm pixel size, 16-bit ADC high-definition image details.
X-ray Tube Assembly

High anode heat content:The anode heat content of the tube is 150kHU, which can achieve more stable continuous exposure performance and better meet the requirements of continuous work.
Photography Stand


DICOM 3.0 networking interface for seamless integration Into
your PACS or RlS system.
*Digital Storage: Quick and convenient,save the cost Comparing with traditional film storage.
*Image Process: Multi-grade denoise, LlH,negative &positive images, image reverse and so on
*Medical History Management:Database management,Graphic reports, Support WORKLIST
*Digital Printer: can be connect with laser printer to print film.
*Digital Network:Support DICOM 3.0 and PACS network in hospital.