TNN10
Customized
CE, FDA, EEC, ISO13485
Medium
with Alarm Function
Cryobiology Cooling Device
Air Cooling
Microcomputer
Hydrocarbon Refrigeration
Cyclopentane
Plywood Box
China
8418401000
Product Description
Model number | MCO-170I | MCO-170 | MCO-170MP | |||||||||||||
External Dimensions (W x D x H) | 620× 772 × 907 mm. | 620× 772 × 907 mm. | 620× 772 × 907 mm. | |||||||||||||
Internal Dimensions (W x D x H) | 490 × 525× 666 mm. | 490 × 525× 666 mm. | 490 × 525× 666 mm. | |||||||||||||
Volume | 170L. | 170L. | 170L. | |||||||||||||
Net weight | 100kg | 100kg | 100kg | |||||||||||||
Performance | ||||||||||||||||
Temperature control range | AT+5~50ºC | AT+5~50ºC | AT+5~50ºC | |||||||||||||
Temperature Uniformity | ±0.25ºC(AT:22°C,Settings:37°C,CO2:5%,no load ) | ±0.25ºC(AT:22°C,Settings:37°C,CO2:5%,no load ) | ±0.25ºC(AT:22°C,Settings:37°C,CO2:5%,no load ) | |||||||||||||
Temperature Fluctuation | ±0.1°C(AT:22°C,Settings:37°C,CO2:5%,no load ) | ±0.1°C(AT:22°C,Settings:37°C,CO2:5%,no load ) | ±0.1°C(AT:22°C,Settings:37°C,CO2:5%,no load ) | |||||||||||||
CO2 concentration control method | PID | PID | PID | |||||||||||||
Display | 7 inch LCD | 7 inch LCD | 7 inch LCD | |||||||||||||
CO2 sensor | IR sensor | TC sensor | IR sensor | |||||||||||||
CO2 Control Range | 0 ~ 20 % | 0 ~ 20 % | 0 ~ 20 % | |||||||||||||
CO2 Fluctuation | ±0.15 %(AT:22°C,Settings:37°C,CO2:5%,no load ) | ±0.15 %(AT:22°C,Settings:37°C,CO2:5%,no load ) | ±0.15 %(AT:22°C,Settings:37°C,CO2:5%,no load ) | |||||||||||||
Ambient temperature | 5~35ºC | 5~35ºC | 5~35ºC | |||||||||||||
Heating method | Direct Heat & Air Jacket System | Direct Heat & Air Jacket System | Direct Heat & Air Jacket System | |||||||||||||
Humidification method | Natural evaporation of water in the tray | natural evaporation of water in the tray | natural evaporation of water in the tray | |||||||||||||
Humidity Level & Fluctuation | 95±5% | 95±5% | 95±5% | |||||||||||||
Noise Level (db) | ≤45dB(A) | ≤45dB(A) | ≤45dB(A) | |||||||||||||
Sterilization method | UV lamp 4W×1 | UV lamp 4W×1 | UV lamp 4W×1 | |||||||||||||
Circulation method | Air stirring type | Air stirring type | Air stirring type | |||||||||||||
O2 concentration control method | None | None | PID | |||||||||||||
O2 sensor | None | None | Zirconia | |||||||||||||
O2 Control Range | None | None | 2~18%, 22~80% | |||||||||||||
O2 Fluctuation | None | None | ±0.15 %(AT:22°C,Settings:37°C,CO2:5%,no load ) | |||||||||||||
Pull up and pull down | ||||||||||||||||
Temperature and carbon dioxide concentration recovery curve 30s +60s after opening the door | ||||||||||||||||
Construction | ||||||||||||||||
Exterior Material | Painted Steel | Painted Steel | Painted Steel | |||||||||||||
Interior Material | SUS304 steel | SUS304 steel | SUS304 steel | |||||||||||||
Insulation materials | PUF | PUF | PUF | |||||||||||||
Outer Doors/Lid | Painted Steel | Painted Steel | Painted Steel | |||||||||||||
Outer Door Lock | Optional | Optional | Optional | |||||||||||||
Inner Doors/Lid | Tempered glass | Tempered glass | Tempered glass | |||||||||||||
Tray material | SUS304 | SUS304 | SUS304 | |||||||||||||
Tray deminsion | 469*444*9mm | 469*444*9mm | 469*444*9mm | |||||||||||||
Tray number | 4pcs | 4pcs | 4pcs | |||||||||||||
Filter | 0.3um efficiency: more than 99.97% | 0.3um efficiency: more than 99.97% | 0.3um efficiency: more than 99.97% | |||||||||||||
CO2 connection port | Pagoda connector | Pagoda connector | Quick plug connector | |||||||||||||
O2 connection port | ||||||||||||||||
Controller | ||||||||||||||||
Temp sensor | Dual IR sensor | Dual IR sensor | Dual IR sensor | |||||||||||||
Accuracy value | 0.1 | 0.1 | 0.1 | |||||||||||||
UV lamp | 4W×1 | 4W×1 | 4W×1 | |||||||||||||
Access Port | 1 | 1 | 1 | |||||||||||||
Access Port Position | Back | Back | Back | |||||||||||||
Access Port Diameter | 30mm | 30mm | 30mm | |||||||||||||
Casters | Adjustable feet | Adjustable feet | Adjustable feet | |||||||||||||
Alarm(V = Visual Alarm, B = Buzzer Alarm, R = Remote Alarm) | ||||||||||||||||
CO2 concentration exceeds upper limit alarm | V-B-R | V-B-R | V-B-R | |||||||||||||
CO2 concentration exceeds lower limit alarm | V-B-R | V-B-R | V-B-R | |||||||||||||
Door open alarm | V-B-R | V-B-R | V-B-R | |||||||||||||
Alarm for empty CO2 cylinder or CO2 solenoid valve failure | V-B-R | V-B-R | V-B-R | |||||||||||||
UV lamp alarm | V-B-R | V-B-R | V-B-R | |||||||||||||
Ambient temperature sensor failure | V-B-R | V-B-R | V-B-R | |||||||||||||
High temperature protection sensor failure in the box | V-B-R | V-B-R | V-B-R | |||||||||||||
High temperature alarm inside the box | V-B-R | V-B-R | V-B-R | |||||||||||||
Low temperature alarm inside the box | V-B-R | V-B-R | V-B-R | |||||||||||||
High temperature protection alarm inside the box | V-B-R | V-B-R | V-B-R | |||||||||||||
Electrical | ||||||||||||||||
Power Supply(V) | 220 | 230 | 230 | |||||||||||||
frequency (Hz) | 50 | 50 | 50 | |||||||||||||
Rated input power | 330W | 330W | 343W | |||||||||||||
Power consumption | 1.4kW▪h/24h | 1.4kW▪h/24h | - | |||||||||||||
Standard Accessories | ||||||||||||||||
Accessories | Tray×4,gas pipe×1,gas pipe clip×2,humidification tray×1,stacking board×1,wear pad×2,M4 screw×4,M5 gasket×4,M8 gasket×4 | Tray×4,gas pipe×1,gas pipe clip×2,humidification tray×1,stacking board×1,wear pad×2,M4 screw×4,M5 gasket×4,M8 gasket×4 | Tray×4,gas pipe×1,gas pipe clip×2,humidification tray×1,stacking board×1,wear pad×2,M4 screw×4,M5 gasket×4,M8 gasket×4 | |||||||||||||
Options | ||||||||||||||||
Options | Platform trolley | Platform trolley | Platform trolley | |||||||||||||
Electronic lock | Electronic lock | Electronic lock | ||||||||||||||
Communication Systems | ||||||||||||||||
Standard port | ||||||||||||||||
Optional port | RS485,USB | RS485,USB | RS485,USB | |||||||||||||
Quality Management System | ||||||||||||||||
Certification | CE, ISO13485, ISO9001, ISO14001 | CE, ISO13485, ISO9001, ISO14001 | - |

emperature Control System
• Controlled by micro-computer, LCD display, touched screen;
• The inner temperature can be adjusted at the range of -40ºC--86ºC,the temperature regulation accuracy is 0.1ºC.
Security Control System
• Multi malfunction alarms: high temperature alarm, low temperature alarm, sensor malfunction alarm, condenser dirty alarm, low battery alarm, power failure alarm, over pressure alarm, over ambient temperature alarm, open the door alarm and so on for safe use;
• Besides, you can check history alarming information and derive data. All the history data can be saved over 10 years;
• Three alarming methods: buzzer alarming, independent icon alarming, and remote alarming:
• Protection function: compressor power-on delay protection, time between power off; overpressure protection, password, protection and normal operation protection under failure mode;
• Password protection can prevent parameters from being changed randomly;
• Display screen with running indication and communication status indication can show real-time operation of the freezer;
•The power switch has two-way fuse overcurrent protection, together with the power -on indicator light ensure safety.
• Controlled by micro-computer, LCD display, touched screen;
• The inner temperature can be adjusted at the range of -40ºC--86ºC,the temperature regulation accuracy is 0.1ºC.
Security Control System
• Multi malfunction alarms: high temperature alarm, low temperature alarm, sensor malfunction alarm, condenser dirty alarm, low battery alarm, power failure alarm, over pressure alarm, over ambient temperature alarm, open the door alarm and so on for safe use;
• Besides, you can check history alarming information and derive data. All the history data can be saved over 10 years;
• Three alarming methods: buzzer alarming, independent icon alarming, and remote alarming:
• Protection function: compressor power-on delay protection, time between power off; overpressure protection, password, protection and normal operation protection under failure mode;
• Password protection can prevent parameters from being changed randomly;
• Display screen with running indication and communication status indication can show real-time operation of the freezer;
•The power switch has two-way fuse overcurrent protection, together with the power -on indicator light ensure safety.

Refrigeration System
• Optimized cascade refrigeration technology, special evaporation system and condensation system, strong refrigerating efficiency;
• International famous brand compressor and EBM fan electromotor and oil separator, stable product performance, strong refrigerating efficiency;
•Enhanced sealing design: double door seal;
•Heating-free pressure-balanced valve (patent), easy to open the door, keep the cold air and avoid the freezer on fire.
Humanized Design
• Unique handle design: the door can be opened by both hands, individual press lock on the handle and 2 padlocks;
• Unique "Thin Body" (only DW-86L348) design and detachable handle help the freezer go through the narrow doors;
• Wide voltage design can help it work stably under 198-254V;
• Can show the temperature curve and history data, and have derive data function;
• Press-out type dust removal cover with locks, simple and convenient for maintenance;
• Thermometer holes design for temperature examination.
• Optimized cascade refrigeration technology, special evaporation system and condensation system, strong refrigerating efficiency;
• International famous brand compressor and EBM fan electromotor and oil separator, stable product performance, strong refrigerating efficiency;
•Enhanced sealing design: double door seal;
•Heating-free pressure-balanced valve (patent), easy to open the door, keep the cold air and avoid the freezer on fire.
Humanized Design
• Unique handle design: the door can be opened by both hands, individual press lock on the handle and 2 padlocks;
• Unique "Thin Body" (only DW-86L348) design and detachable handle help the freezer go through the narrow doors;
• Wide voltage design can help it work stably under 198-254V;
• Can show the temperature curve and history data, and have derive data function;
• Press-out type dust removal cover with locks, simple and convenient for maintenance;
• Thermometer holes design for temperature examination.




Dedicated in bio-science, Alphavita Bio-scientific (Dalian) Co., Ltd. (Alphavita) is a professional provider of comprehensive solutions for laboratory area, and clinical application. Based in sample preservation, Alphavita is cable of exploring sample resources in-depth.
Alphavita is a new brand born with the development of Sanyo and Panasonic. Sanyo Electric Co., Ltd., as the top provider of lab equipment, was widely recognized in research and medical fields after its first launch in China in the 1970s. After Panasonic's acquisition of Sanyo Electric Co., Ltd. in 2012, the brand was changed from Sanyo to Panasonic. In 2018, Alphavita completed the integration with Panasonic's Biomedical Business Division, becoming the sole enterprise to run Panasonic's former biomedical business in China. While using the brand Panasonic legally and independently, we created a new brand - Alphavita in 2019, to officially start our business in life science.
Alphavita is a new brand born with the development of Sanyo and Panasonic. Sanyo Electric Co., Ltd., as the top provider of lab equipment, was widely recognized in research and medical fields after its first launch in China in the 1970s. After Panasonic's acquisition of Sanyo Electric Co., Ltd. in 2012, the brand was changed from Sanyo to Panasonic. In 2018, Alphavita completed the integration with Panasonic's Biomedical Business Division, becoming the sole enterprise to run Panasonic's former biomedical business in China. While using the brand Panasonic legally and independently, we created a new brand - Alphavita in 2019, to officially start our business in life science.

While inheriting Sanyo's and Panasonic's proven technologies, Alphavita devotes itself to 4 categories of products: sample preservation product, sterilization product, cell culture product and lab environment equipment, aiming to improve enterprise competitiveness and user-friendliness on a digital and intelligent basis.
On the strength of Panasonic's business operation in China for more than 50 years, Alphavita will inherit and continue Sanyo's and Panasonic's concept and technology. With "To Protect Life with Bio-science" as our mission, Alphavita will keep challenging, making breakthroughs and contributions to the development of life science in China and the whole world.
On the strength of Panasonic's business operation in China for more than 50 years, Alphavita will inherit and continue Sanyo's and Panasonic's concept and technology. With "To Protect Life with Bio-science" as our mission, Alphavita will keep challenging, making breakthroughs and contributions to the development of life science in China and the whole world.