Megger MIT2500
Yes
1 Year Warranty
Digital Only
RoHS, CE
Non-Customized
Megger
Mit2500
15 to 400 Hz
>1000 Test Results
50V to 2500V
IP54
33*30*12cm
2kg
megger
DHL/UPS/FedEx
33*30*12cm
U. K.
9030331000
Product Description
Designed for motor and cable testing, specialist applications and electrical testing applications, where operation voltages exceed 1000 V and higher insulation test voltage needed. The MIT2500 offers both fixed range voltages of 50, 100, 500, 1000 and 2500 V, as well as a range that allows any voltage between 50 and 2500 V to be "dialed in". This is supported by the new test voltage feedback control, which maintains the output test voltage to within 2% of the selected range, even when under test.
The MIT2500 Insulation and Continuity Tester has been designed for motor and cable testing, specialist applications and electrical testing applications, where operation voltages exceed 1000 V and higher insulation test voltages are needed.
The MIT2500 offers both fixed range voltages of 50 V, 100V, 250 V, 500 V, 1000 V and 2500 V, as well as a variable range that allows any voltage between 50 V and 2500 V to be "dialled in". This is supported by the new test voltage feedback control, which maintains the output test voltage to within 2% of the selected range, even when under test.

Megger MIT2500 - 2500V Insulation Tester
- Guard terminal for high resistance accuracy
- Adjustable insulation test voltage from 50 V to 2500 V
- Stabilised insulation test voltage
- Rechargeable options for mains and car charging
The MIT2500 offers both fixed range voltages of 50 V, 100V, 250 V, 500 V, 1000 V and 2500 V, as well as a variable range that allows any voltage between 50 V and 2500 V to be "dialled in". This is supported by the new test voltage feedback control, which maintains the output test voltage to within 2% of the selected range, even when under test.
Insulation | |
Accuracy | 50 V, 10 GΩ ± 2%, ±2 digits ±4% per GΩ 100 V, 20 GΩ ± 2%, ±2 digits ±2% per GΩ 250 V, 50 GΩ ± 2%, ±2 digits ±0.8% per GΩ 500 V, 100 GΩ ± 2%, ±2 digits ±0.4% per GΩ 1000 V, 200 GΩ ± 2%, ±2 digits ±0.2% per GΩ 2500 V, 200 GΩ ± 2%, ±2 digits ±0.2% per GΩ Service error: BS EN 61557-2 (2007) 50 V, ± 2% ±2d, 100 to 900 kΩ ±10.5% 100V, ± 2% ±2d, 100 to 900 kΩ ±10.3% 250 V, ± 2% ±2d, 100 to 900 kΩ ±10.3% 500 V, ± 2% ±2d, 100 to 900 kΩ ±10.3% 1000 V, ± 2% ±2d, 100 to 900 kΩ ±11.5% |
Guard Terminal Performance | <5% error at 500 kΩ parallel circuit resistance with 100 MΩ load |
Display Range | Analogue: 1 GΩ full scale |
Resolution | 0.1 kΩ |
Short Circuit/Charge Current | 2 mA +0% -50% to EN 61557-2 (2007), except 2500 V |
Terminal Voltage Accuracy | -0%, 2%, ±2 V |
Test Current | 1 mA at minimum pass value of insulation to a maximum of 2 mA maximum |
Operation | EN61557: 0.1 MΩ to 1 GΩ |
Maximum Capacitive Load | 15 nF on tests above 1000 V |
Leakage Current Display | 10% ±3 digits |
Voltage | ±3% ±2 digits ±0.5% of rated voltage |
Timer Control | Countdown timer 60 second (adjustable to 10 minutes) *Note: The "Insulation" specifications only apply when high quality silicone leads are being used. |
Continuity | |
Measurement | 0.01 Ω to 1 MΩ (0 to 1000 kΩ on analog scale) |
Accuracy | ±3% ±2 digits (0 to 100 Ω) ±5% ±2 digits (100 Ω to 500 kΩ) Service error: BS EN 61557-4 (2007) - ±2%, 0.1 to 2 Ω ±6.8% |
Open Circuit Voltage | 5 V ± 1 V |
Test Current | 200 mA (–0 mA, 20 mA), 0.01 to 4 Ω |
Polarity | Single polarity (default)/dual polarity (configurable on setup) |
Lead Resistance | Null up to 10 Ω |
General Specifications | |
Voltage | Range: DC: 0 to 600V AC: 10 mV to 600 V TRMS sinusoidal (15 to 400 Hz) Unspecified: 0 to 10 mV (15 to 400 Hz) Accuracy: AC: ±2% ±2 digits Service error: BS EN 61557-1 (2007) - ±2% ±2d, 0 V 300 V AC/DC ±5.1% Waveform: Non-sinusoidal: ±3% ±2 digits >100 mV to 600 V TRMS ±8% ±2 digits 10 to 100 mV TRMS Default voltmeter: ±0.5% ±1 digit (100 to 400 Hz) unspecified |
Frequency | Measurement range: 15 to 400 Hz Measurement accuracy: ±0.5% ±1 digits |
Capacitance Measurement | Capacitance range: 0.1 nF to 10 µF Accuracy: ±5% ± 2 digits (1 nF to 10 µF) |
Storage Capacity | >1000 test results |
Data Download | Bluetooth® wireless Bluetooth® Class II |
Range | Up to 32.8' (10 m) |
Temperature | Operating: 14 to 131°F (-10 to 55°C) Storage: -13 to 158°F (-25 to 70°C) Calibration: 68°F (20°C) Co-efficient: <0.1% per °C up to 1 GΩ <0.1% per °C per GΩ above 1 GΩ |
Humidity | 90% RH at 104°F (40°C) maximum |
Power Supply | 6 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) alkaline 6 x 1.2 NiMH rechargeable cells may be used |
Battery Life | 3000 insulation tests with duty cycle of 5 seconds ON /55 sec OFF at 1000 V into 1 MΩ |
Maximum Altitude | 6561.68' (2000 m) |
Fuse | Use only 2 x 500 mA (FF) 1000 V 1.26 x 0.24" (32 x 6 mm) ceramic fuse of high breaking capacity HBC 30 kA minimum |
Safety Protection | The instruments meet EN 61010- 1:2010 and EN 61010-2-030:2010 to 600 V phase to earth, Category IV. Refer to safety warnings supplied |
EMC | In accordance with IEC 61326 including amendment No.1 |
IP Rating | IP54 |
Dimensions | 9 x 4.25 x 2.32" (228 x 108 x 63 mm) |
Weight | 1.13 lbs (815 g) In the case: 3.14 lbs (1.75 kg) *Note: All quoted accuracies are at 68°F (20°C) |
What's included with the Megger MIT2500
- Hand-Held Insulation and Continuity Tester
- Red/Black/Blue Silicone Test Leads with Prods and Clips
- 2.5 kV Red/Black/Blue Silicone Test Leads with Clips
- Carrying Case
- 6 x AA Alkaline Batteries
- Owner's Information CD