SZY-136
Submersible
Contact
Customizable
Ceramics
Good Stability and Accuracy
Stainless Steel
IP68
CE
Customized
0~1....50m.....500m
4~20mA (Default), 0~5V, 0~10V (Customized)
0.5% (0.2% Can Be Customized)
≤0.5fs%
≤0.2fs%
≤0.2%Fs/4h
≤0.04%Fs/ºC
≤0.2%Fs/Year
24VDC (Default), 12V, 5V (Customized)
0~50ºC
-20~70ºC (Recommended Below 50ºC)
300%
>1×10^8 Pressure Cycle (25ºC)
Various Liquids Compatible with 304
316L Stainless Steel
Aice Tech
Cartons
26*21*16cm 1kg
China
9026100000
Product Description
Submersible Hydrostatic Liquid Level Sensor

Product Features
Good stability, high accuracy, high performance / price ratio, directly into the measured medium, installation
and use is quite convenient, solid-state structure, no moving parts, high reliability, long service life, from water, oil
to viscosity of the larger paste can be measured with high accuracy, not affected by the measured medium blistering,
deposition, electrical characteristics no material fatigue wear, insensitive to vibration, shock no polarity 4-20mA
output.
Working Principle
Measuring principle by hydrostatic pressure
When the level transmitter is put into the measured liquid at a certain depth, the pressure on the liquid surface
of the sensor is P=ρ.g.h+P0 in the formula
P: the pressure on the liquid surface of the sensor
Unit:Pa
ρ: density of the measured liquid
Unit:Kg/m³
g: local acceleration of gravity
Unit:m/s²
P0:Atmospheric pressure on the liquid surface
Unit:Pa
H: sensor into the liquid depth
Unit:m
At the same time, the atmospheric pressure P0 on the liquid surface is introduced into the back pressure
chamber of the sensor through the air guide cable to offset the P0 on the liquid surface of the sensor, so that the
pressure measured by the sensor is P=ρ.g.h. Obviously, the liquid level depth H can be obtained by measuring the
pressure P. The pressure signal sensed by the sensor is converted and amplified by the circuit and output as a
standard signal after compensation.
Note: This model is used for open container level measurement.

Note: This model is used for open container level measurement.
Technical parameters
-Measurement range: 0-500m (range can be customized at will)
-Output signal:4-20mA(default), 0-5V, 0-10V, 0.5-4.5V, RS485
-Measurement accuracy:0.5%(default), 0.25%
-Nonlinearity:≤0.5FS%
-Repeatability:≤0.2FS%
-Zero drift: ≤0.2%FS/4H
-Temperature drift: ≤0.04%FS/ºC
-Stability: ≤0.2%FS/year
-Operating voltage: DC 24V (default), DC 12V, DC 5V
-Compensation temperature:0~50ºC
-Working temperature:-20~70ºC
-Overload capacity:300%
-Measurement medium:Liquid compatible with 304 (can be customized with 316L stainless steel)
-Shell material: 304 stainless steel
-Diaphragm material: 316L stainless steel
-Cable material: polyurethane (customizable PTFE)
-Protection level: IP68

Range | 0~1....50m.....500m |
Output signal | 4~20mA (default), 0~5V, 0~10V (customized) |
Measurement accuracy | 0.5% (0.2% can be customized) |
Nonlinear | ≤0.5FS% |
Repeatability | ≤0.2FS% |
Zero drift | ≤0.2%FS/4H |
Temperature drift | ≤0.04%FS/ºC |
Stability | ≤0.2%FS/year |
Operating Voltage | 24VDC (default), 12V, 5V (customized) |
Compensated temperature | 0~50ºC |
Operating temperature | -20~70ºC (recommended below 50ºC) |
Overload capacity | 300% |
Measuring medium | >1×10^8 pressure cycle (25ºC) |
Shell material | Various liquids compatible with 304 |
Diaphragm material | 316L stainless steel |
Protection class | IP68 |