CS310X(Option A)
Free
3 Years
Wuhan Corrtest Instruments
4
+/- 1A on Each Channel
+/- 10V
10uhz~1MHz
Energy, Materials, Battery, Corrosion, etc
Support
Corrtest
Standard Carton
4-channel
China
9027899090
Product Description
Corrtest Multichannel potentiostat/ galvanostat/EIS is a versatile instrument offering 8 slots.
Multichannel potentiostat/ galvanostat model CS310X (Option A) is the 4-channel potentiostat. 4 slots are occupied with potentiostat boards. The rest 4 slots are unoccupied for future adding potentiostat board(s). Option A equals that you have 4 sets independent single-channel potentiostat/galvanostat in one chassis.
EIS module (10μHz~1MHz) is equipped in only ONE channel. Each channel potential control range is ±10V, current control range ±1A, can meet experiment requirement for most people.
Full floating module and electrical isolation design guarantee each channel is totally independent, which ensures accurate data and efficient simultaneous measurements.
4-channel potentiostat
Application
- Reaction mechanism of Electrosynthesis, electrodeposition (electroplating), anodic oxidation.
- Electrochemical analysis, electro-catalysis, sensor;
- New energy materials, advanced functional materials, photoelectronic materials;
- Corrosion study of metals in water, concrete and soil etc;
- Fast evaluation of corrosion inhibitor, water stabilizer, coating and cathodic protection efficiency.
There are 4 basic options for CS310X.
Option A: 4-channel with EIS in one channel
Option B: 4-channel, with EIS in all four channels
Option C: 8-channel, with EIS in one channel
Option D: 8-channel, with EIS in all 8 channels
The number of the channel and EIS modules can be cusomized.
Lower model can be upgraded to higher one by adding more potentiostat boards on current device
EIS module can be upgraded online.
Specifications
Techniques
Stable polarization
Simultaneous Measurements
You can choose a same electrochemical technique in every channel. As is shown in below picture, we let 4 channels do EIS.

In each channel, the user can also choose different experiments. Set the parameters for experiment in each channel and start simultaneous measurements. As is shown in the below picture, EIS, galvanostatic charge and discharge, CV, and polarization curve tests are conducted at the same time.

Multichannel potentiostat/ galvanostat model CS310X (Option A) is the 4-channel potentiostat. 4 slots are occupied with potentiostat boards. The rest 4 slots are unoccupied for future adding potentiostat board(s). Option A equals that you have 4 sets independent single-channel potentiostat/galvanostat in one chassis.
EIS module (10μHz~1MHz) is equipped in only ONE channel. Each channel potential control range is ±10V, current control range ±1A, can meet experiment requirement for most people.
Full floating module and electrical isolation design guarantee each channel is totally independent, which ensures accurate data and efficient simultaneous measurements.

Application
- Reaction mechanism of Electrosynthesis, electrodeposition (electroplating), anodic oxidation.
- Electrochemical analysis, electro-catalysis, sensor;
- New energy materials, advanced functional materials, photoelectronic materials;
- Corrosion study of metals in water, concrete and soil etc;
- Fast evaluation of corrosion inhibitor, water stabilizer, coating and cathodic protection efficiency.
There are 4 basic options for CS310X.
Option A: 4-channel with EIS in one channel
Option B: 4-channel, with EIS in all four channels
Option C: 8-channel, with EIS in one channel
Option D: 8-channel, with EIS in all 8 channels
The number of the channel and EIS modules can be cusomized.
Lower model can be upgraded to higher one by adding more potentiostat boards on current device
EIS module can be upgraded online.
Model | CS310X | |||
Options | Option A | Option B | Option C | Option D |
Number of channels | 4 | 4 | 8 | 8 |
Max. current on each channel | ±1A | ±1A | ±1A | ±1A |
Potential range on each channel | ±10V | ±10V | ±10V | ±10V |
EIS (10μHz~1MHz) | Included on 1 channel only | Included on all 4 channels | Included on 1 channel only | Included on all 8 channels |
Standard supply | Instrument host CS310X-1 set CS studio6 software, Power cable - 1 piece, Ethernet cable - 1 piece Electrode cable -8 pcs Dummy cell, Manual | Instrument host CS310X-1 set CS studio6 software, Power cable - 1 piece, Ethernet cable - 1 piece Electrode cable -16 pcs Dummy cell, Manual |
Specifications
Specifications | |
Number of channels with boards: 4 | Channel insulation resistance: >100MΩ |
Communication: Ethernet | Lower-pass filter: covering 8-decade |
Potential control range: ±10V | Constant current control range: ±1A on each channel |
Potential accuracy: 0.1%×full range±1mV | Current accuracy: 0.1%×full range |
Potential resolution:10μV(>100Hz), 3μV(<10Hz) | Current resolution: 1pA |
Potential rise time: <1μs(<10mA), <10μs(<2A) | Current range: 2nA ~1A, 10 ranges |
Reference electrode input impedance: 1012Ω||20pF | Maximum current output: ±1A |
Compliance voltage: ±21V | Current increment during scan: 1mA @1A/ms |
CV and LSV scan rate: 0.001mV~10000V/s | Potential increment during scan: 0.076mV@1V/ms |
CA and CC pulse width: 0.0001~65000s | DPV and NPV pulse width: 0.0001~1000s |
SWV frequency:0.001~100KHz | CV minimum potential increment: 0.075mV |
AD data acquisition:16bit@1MHz,20bit @1kHz | IMP frequency:10μHz~1MHz |
DA resolution:16bit, setup time:1μs | Current and potential range: automatic |
Operating System requirements: Windows 10/11 | Weight: 12.5 Kg Dimensions: 40*40*14cm |
Electrochemical Impedance Spectroscopy (EIS) | |
Signal generator | |
Frequency range: 10μHz~1MHz | AC signal amplitude: 1mV~2500mV |
Frequency accuracy: 0.005% | Signal resolution: 0.1mV RMS |
DDS output impedance: 50Ω | DC Bias: -10V~+10V |
Wave distortion: <1% | Waveform: sine wave, triangular wave, square wave |
Scan mode: Logarithmic/linear, increase/decrease | |
Signal analyzer | |
Maximum integral time:106 cycles or 105s | Measurement delay:0~105S |
Minimum integral time:10ms or the longest time of a cycle | |
DC offset compensation | |
Potential compensation range: -10V~+10V | Current compensation range: -1A~+1A |
Bandwidth adjustment: automatic and manual, 8-decade frequency range |
Techniques
Stable polarization
- Open Circuit Potential (OCP)
- Potentiostatic (I-T curve)
- Galvanostatic
- Potentiodynamic (Tafel plot)
- Galvanodynamic (DGP)
- Multi Potential Steps
- Multi Current Steps
- Potential Stair-Step (VSTEP)
- Galvanic Stair-Step (ISTEP)
- Chronopotentiometry (CP)
- Chronoamperametry (CA)
- Chronocaulometry (CC)
- Linear Sweep Voltammetry (LSV)
- Cylic Voltammetry (CV)
- Staircase Voltammetry (SCV) #
- Square Wave Voltammetry (SWV) #
- Differential Pulse Voltammetry (DPV) #
- Normal Pulse Voltammetry (NPV)#
- Differential Normal Pulse Voltammetry (DNPV) #
- AC Voltammetry (ACV) #
- 2nd harmonic AC Voltammetry (SHACV)
- Fourier Transform AC Voltammetry (FTACV)
- Battery Charge and Discharge
- Galvanostatic Charge and Discharge (GCD)
- Potentiostatic Charging and Discharging(PCD)
- Potentiostatic Intermittent Titration Technique (PITT)
- Galvanostatic Intermittent Titration Technique (GITT)
- Potentiostatic EIS (Nyquist, Bode)
- Galvanostatic EIS
- Potentiostatic EIS (Optional freq.)
- Galvanostatic EIS(Optional freq.)
- Mott-Schottky
- Potentiostatic EIS vs. Time (Single freq.)
- Galvanostatic EIS vs. Time (Single freq.)
- Cyclic polarization curve (CPP)
- Linear polarization curve (LPR)
- Electrochemical Potentiokinetic Reactivation (EPR)
- Electrochemical Noise (EN)
- Zero resistance Ammeter (ZRA)
- Differential Pulse Amperometry (DPA)
- Double Differential Pulse Amperometry (DDPA)
- Triple Pulse Amperometry (TPA)
- Integrated Pulse Amperometric Detection (IPAD)
Simultaneous Measurements
You can choose a same electrochemical technique in every channel. As is shown in below picture, we let 4 channels do EIS.

In each channel, the user can also choose different experiments. Set the parameters for experiment in each channel and start simultaneous measurements. As is shown in the below picture, EIS, galvanostatic charge and discharge, CV, and polarization curve tests are conducted at the same time.