Product Description
- Illuminate your operations with the crisp, clear clarity of our 7-bit LED display, designed to deliver precise readability even in challenging environments.
- Empower your weighing capabilities with our support for a single analog scale input, accommodating up to a robust 12 load cells, ensuring unparalleled accuracy and reliability.
- Certification: Boasting an impressive CPA 6000e certification, this scale achieves a division up to a remarkable 150,000, setting new standards in precision.
- Connectivity redefined with standard serial ports: Choose between 2 RS232 + RS232/485, or 2 RS232 + RS485 configurations, each enhanced with a LAN port for versatile networking.
- Experience seamless integration with our standard support for MODBUS-RTU, and for those opting for the ethernet version, enjoy MODBUS-TCP functionality.
- Enhance your system's versatility with our optional PLC communication interface, tailored to meet the most demanding industrial standards.
- Connect with precision using PROFIBUS-DP, ideal for Siemens PLC, and CC-link, perfectly suited for Mitsubishi PLC applications.
- Navigate the future of connectivity with our PROFINET capability, featuring dual LAN ports and a built-in switch, optimized for Siemens PLC systems.
- Advance your automation with EtherNet/IP, offering dual LAN ports and a built-in switch, compatible with Rockwell PLC and Delta PLC, ensuring seamless integration.
- Scale with precision using our 4-20 mA outputs: Choose from a single scale with 16-bit precision DAC or dual scales, both delivering exceptional accuracy.
- Customize your system effortlessly with our optional I/O (input/output), providing the flexibility to adapt to evolving operational needs.
- Harness the power of comprehensive control with 8 input channels and 12 open-collector output channels, designed for versatile applications.
- Achieve precision with ease through our multiple calibration modes, tailored to suit diverse operational requirements.
- Optimize accuracy with up to 5-point weight calibration or choose the convenience of calibration without weights, ensuring flexibility in setup.
- Simplify the calibration process with remote calibration via our advanced PLC communication interface, streamlining your operations.
- Application supports: Tailor your solutions with our adaptable application support, designed to meet the specific demands of your industry.
- Versatile applications: Basic weighing version includes lower and upper limit level detection, ensuring reliability and precision.
- Maximize control with dual-speed preset point control and 8 simple comparison outputs, empowering efficient and precise operations.
- Ensure safety with our built-in load cell safety barrier, enabling direct connections to scale platforms in both Zone 1 and Zone 2 environments.
- Working power supply: Designed for efficiency, our system operates on DC 24VDC with a maximum power consumption of less than 6 W, ensuring sustainability.


Product selection configuration: Tailor your purchase with our flexible product selection options, designed to meet your specific operational needs.
Indicator Model Number | Shell Type | Hardware Sub-item | I/O Option | PLC Interface | Application Sub-items | Language | Power Supply |
ID511XX | H | C | 1 | 0 | 0 | 0 | D |
ID511XX | H: Zone 2 explosion-proof and dustproof housing | C: RS232+RS232/485 E: LAN+RS232+RS485 | 0: None 1: In x 8 / OC Out x 12 3: In x 8 / MOS Out x 12 | 0: None A: Scale x 1 4-20mA output B: Scales x 2 4-20mA output C: CC-LINK E: EtherNet/IP F: PROFINET G: EtherNet/IP+scale x 1 4-20mA H: PROFINET+scale x 1 4-20mA P: PROFIBUS communication interface T: EtherCAT U: EtherCAT + scale x 1 4-20mA output V: PROFIBUS-DP + scale x 1 4-20mA K: CCLINK IE FB | 0: Standard application | 0: Chinese 1: English | D: 24VDC no power cable |
Common configuration: Choose our common configuration for a straightforward, reliable setup that meets everyday operational demands.
Material No. | Configuration Model | Configuration Description |
851108T | ID511XXHC0000D | ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS232/485), MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable |
851108U | ID511XXHE0000D | ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS485) and 100m LAN port, MODBUS-RTU, MODBUS-TCP, basic application software version, 7-bit LED display, 24VDC no power cable |
851108V | ID511XXHC1000D | ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, intrinsically safe explosion-resistant load cell output interface), serial ports x 2 (RS232 + RS232/485), In x 8 / OC Out x 12, MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable |
851108X | ID511XXHC0P00D | ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS232/485), PROFIBUS communication interface, MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable |
851108Y | ID511XXHC0A00D | ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, intrinsically safe explosion-resistant load cell output interface), serial ports x 2 (RS232 + RS232/485), 4-20 mA analog output interface, MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable |
851108Z | ID511XXHC0B00D | ID511, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS232/485), 4-20 mA analog output interface x2, MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable |
8511090 | ID511XXHC0C00D | ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS232/485), CC-LINK communication interface, MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable |
8511091 | ID511XXHC0E00D | ID511, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS232/485), EtherNet/IP communication interface, MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable |
8511092 | ID511XXHC0F00D | ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS232/485), PROFINET communication interface, MODBUS-RTU, basic application software version, 7-bit LED display, 24VDC no power cable |
85110E6 | ID511XXHC0T00D | ID511XX, 304 stainless steel dustproof housing, zone 2 explosion-proof (gas explosion-proof + dust explosion-proof, output interface of intrinsically safe anti-explosion load cell), serial ports x 2 (RS232 + RS232/485), MODBUS-RTU, EtherCAT communication interface, basic application software version, 7-bit LED display, 24VDC no power cable |


Desktop placement | Wall bracket installation |