A6
Anaesthesia Machine
Operation
ISO13485
Adult
With LCD Display
KOJUI
Wooden Carton
Nanjing
Product Description
Anaesthesia Machine NewBright A6


ADVANCED DESIGN & MONITORING
Large screen high-definition TFT wide viewing angle color LCD touch screen
New interface design, reasonable layout and color matching
Pressure-Time waveform, Flow-Time waveform display on the same screen
Powerful monitoring and alarm functions
Comprehensive respiratory mechanics monitoring allows you to fully grasp the patient's respiratory status

HIGH-PRECISION VAPORIZER
Vaporizer can support low flow anesthesia as low as 0.2L/min and large flow anesthesia up to 15L/min.
Accurate output of concentrations under varying conditions of pressure, flow and temperature.
Support Selectatec Mounting type and Cagemount compatible
4 Kinds of Vaporizer for Choice: Halothane, Enflurane, Isoflurane and Sevoflurane
Fill-in type: Pouring

INTEGRATED BREATHING CIRCUIT
Integrated breathing circuit with APL valve, excellent tightness and safety.
Made of special materials, resistant to corrosion and high temperature.
Compact structure, no external pipelines, good mechanical compliance.
Impeller sampling is used at the exhalation end to avoid inaccurate monitoring of tidal volume due to water vapor condensation.
Drive bellows is not required to repalce when operating pediatric anesthesia.
Large volume of CO2 canister, single tank structure for more convenient in assembly.
ACGO PORT
With ACGO port to connect with T circuit or BAIN circuit for open-operation.
Convenient for patients'oxygen inhalation and post-operative recovery.

AGSS PORT
AGSS exhaust gas collection system can be installed.
Reduce environmental pollution in the operating room Ensure the safety of medical staff and patients.
TECHNICAL PARAMETERS
PART OF ANESTHESIA MACHINE
Main Body
High-strength engineering plastic rack, light, beautiful and corrosion resistant
Scope of Application:
Adult, Child
Gas Source
O2: 0.28~0.6MPa, N2O: 0.28~0.6MPa
Flow Meter
O2: 0.05~1.0L/min,1.1~10L/min
N2O: 0.05~1.0L/min,1.1~10L/min
O2-N2O Linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.16±0.02Kpa, the flow of nitrous oxide would be cut off.
Flow Rate of Rapid Oxygen Supply
25~75L/min
Low Oxygen Pressure Alarm
There will be sound alarm when the oxygen pressure < 0.2MPa
Vaporizer
It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
Among Halothane,Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer.
Respiratory Circuit
Working mode: All-close, Semi-close, Semi-open
APL: ≤12.5 kPa
Respiratory Bellows
Bellows for adults and children
Tidal volume range:0~1500 ml
Light
Equipped with LED illumination, easy for observation
ACGO Port
With ACGO port to connect with T circuit or BAIN circuit for open-operation.
AGSS Port
AGSS exhaust gas collection system can be installed.
PART OF VENTILATOR
Display Mode
High-definition 10.1"TFT color LCD touch screen display, easy and convenient operation
Ventilation Mode
IPPV, SIPPV, SIMV, MANUAL
Ventilation Function
PEEP,SIGH, IRV
Ventilation Parameters
Tidal volume:50~1500 ml
Rate:2~99 bpm
SIMV rate:2~20 bpm
I:E:2:1~1:8
Inspiratory trigger pressure: -10~20 cmHO
PEEP:2~20 cmHO
Pressure range:5~60 cmHO
SIGH:1.5 times the inspiratory time/ 100 times breath
Parameters For Ventilation Monitoring
Tidal Volume, Ventilation Volume, IPPV Rate, SIMV Rate, I:E, Peak Pressure of Airway, Pressure-Time Waveform, Flow Rate-Time Waveform, PEEP, Inspiratory Trigger Pressure (Average Pressure, FiO2 Oxygen Concentration, Battery Level)
Security Alarm System
Oxygen Concentration Alarm: Upper limit setting range:21%~99%,Low limit setting range:18%~80%
Airway Pressure Alarm: Upper limit setting range:5~60 cmHO,Low limit setting range:0~50cmHO
Per-minute Ventilation Volume Alarm: Upper limit setting range:1~20L/min,Low limit setting range: 0~19L/min
Tidal Volume alarm: Upper limit setting range:100~1500ml,Low limit setting range 0~1400ml
Sustained High Pressure Alarm: It will give alarm when stress have consistently been higher than 25 cmHO for 15s.
Suffocation Alarm: It will give alarm when stress have consistently been higher than 10 cmHO and tidal volume is less than 120ml for 15s.
Tube Escape Alarm: It will give alarm when stress have consistently been less than 2cmHO for 15s.
Low Battery Level Alarm: It will give alarm when battery level is less than 14±0.5V
Negative Pressure Alarm: It will give alarm when airway stress has been less than 10cmHO for 1s.
Power Supply
AC 220V 50Hz
Built-in Li Battery (Work at least for 8 hours)
Options
Mechanical Arms Bracket for Patient Monitor
ETCO2 monitoring2
Large screen high-definition TFT wide viewing angle color LCD touch screen
New interface design, reasonable layout and color matching
Pressure-Time waveform, Flow-Time waveform display on the same screen
Powerful monitoring and alarm functions
Comprehensive respiratory mechanics monitoring allows you to fully grasp the patient's respiratory status

HIGH-PRECISION VAPORIZER
Vaporizer can support low flow anesthesia as low as 0.2L/min and large flow anesthesia up to 15L/min.
Accurate output of concentrations under varying conditions of pressure, flow and temperature.
Support Selectatec Mounting type and Cagemount compatible
4 Kinds of Vaporizer for Choice: Halothane, Enflurane, Isoflurane and Sevoflurane
Fill-in type: Pouring

INTEGRATED BREATHING CIRCUIT
Integrated breathing circuit with APL valve, excellent tightness and safety.
Made of special materials, resistant to corrosion and high temperature.
Compact structure, no external pipelines, good mechanical compliance.
Impeller sampling is used at the exhalation end to avoid inaccurate monitoring of tidal volume due to water vapor condensation.
Drive bellows is not required to repalce when operating pediatric anesthesia.
Large volume of CO2 canister, single tank structure for more convenient in assembly.
ACGO PORT
With ACGO port to connect with T circuit or BAIN circuit for open-operation.
Convenient for patients'oxygen inhalation and post-operative recovery.

AGSS PORT
AGSS exhaust gas collection system can be installed.
Reduce environmental pollution in the operating room Ensure the safety of medical staff and patients.
TECHNICAL PARAMETERS
PART OF ANESTHESIA MACHINE
Main Body
High-strength engineering plastic rack, light, beautiful and corrosion resistant
Scope of Application:
Adult, Child
Gas Source
O2: 0.28~0.6MPa, N2O: 0.28~0.6MPa
Flow Meter
O2: 0.05~1.0L/min,1.1~10L/min
N2O: 0.05~1.0L/min,1.1~10L/min
O2-N2O Linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.16±0.02Kpa, the flow of nitrous oxide would be cut off.
Flow Rate of Rapid Oxygen Supply
25~75L/min
Low Oxygen Pressure Alarm
There will be sound alarm when the oxygen pressure < 0.2MPa
Vaporizer
It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
Among Halothane,Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer.
Respiratory Circuit
Working mode: All-close, Semi-close, Semi-open
APL: ≤12.5 kPa
Respiratory Bellows
Bellows for adults and children
Tidal volume range:0~1500 ml
Light
Equipped with LED illumination, easy for observation
ACGO Port
With ACGO port to connect with T circuit or BAIN circuit for open-operation.
AGSS Port
AGSS exhaust gas collection system can be installed.
PART OF VENTILATOR
Display Mode
High-definition 10.1"TFT color LCD touch screen display, easy and convenient operation
Ventilation Mode
IPPV, SIPPV, SIMV, MANUAL
Ventilation Function
PEEP,SIGH, IRV
Ventilation Parameters
Tidal volume:50~1500 ml
Rate:2~99 bpm
SIMV rate:2~20 bpm
I:E:2:1~1:8
Inspiratory trigger pressure: -10~20 cmHO
PEEP:2~20 cmHO
Pressure range:5~60 cmHO
SIGH:1.5 times the inspiratory time/ 100 times breath
Parameters For Ventilation Monitoring
Tidal Volume, Ventilation Volume, IPPV Rate, SIMV Rate, I:E, Peak Pressure of Airway, Pressure-Time Waveform, Flow Rate-Time Waveform, PEEP, Inspiratory Trigger Pressure (Average Pressure, FiO2 Oxygen Concentration, Battery Level)
Security Alarm System
Oxygen Concentration Alarm: Upper limit setting range:21%~99%,Low limit setting range:18%~80%
Airway Pressure Alarm: Upper limit setting range:5~60 cmHO,Low limit setting range:0~50cmHO
Per-minute Ventilation Volume Alarm: Upper limit setting range:1~20L/min,Low limit setting range: 0~19L/min
Tidal Volume alarm: Upper limit setting range:100~1500ml,Low limit setting range 0~1400ml
Sustained High Pressure Alarm: It will give alarm when stress have consistently been higher than 25 cmHO for 15s.
Suffocation Alarm: It will give alarm when stress have consistently been higher than 10 cmHO and tidal volume is less than 120ml for 15s.
Tube Escape Alarm: It will give alarm when stress have consistently been less than 2cmHO for 15s.
Low Battery Level Alarm: It will give alarm when battery level is less than 14±0.5V
Negative Pressure Alarm: It will give alarm when airway stress has been less than 10cmHO for 1s.
Power Supply
AC 220V 50Hz
Built-in Li Battery (Work at least for 8 hours)
Options
Mechanical Arms Bracket for Patient Monitor
ETCO2 monitoring2