Natural Gas Digital Display Roots Flow Meter Biogas Gas Methane Volumetric Type

Price $2000.00 Compare
Min Order 1 Piece
Shipping From Shanghai, China
Popularity 252 people viewed
Quantity
+-
 

Aister Instrument (Shanghai) Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
ATLQ
Technical Support
1 Year
>±1%
Nature Gas, Gas
DN50-100
Tube/Flange
Industrial Production
Turbine Flow Meter
Gas
Electrical Principles
Closed Pipeline
CE, ISO
DN25 - 250
1:10, 1:20, 1:30
-10~+100 Degree
Three-Wire Pulsing
Carton Box with PP Film Wooden Box
China
9026801000
Product Description
Product Description

Gas Lobed Rotor (Roots) Flowmeter widely used in urban gas trade measurement, especially for organs, schools, enterprises and institutions, hotels, restaurants and other large gas users trade measurement. It can also be used for various industrial raw gas main metering, gas distribution station, main gas supply station and other occasions.

Product Parameters
 
 
ModelFlow Spec
Size
(mm)
Flow Range
(m³/h)
Start up flow
(m³/h)
Max Pressure loss
(KPa)
ATQL-25G16DN251-250.050.08
ATQL-40G25DN401-400.050.08
ATQL-50G25
DN50
1-400.10.08
G402-650.10.1
G652-1000.120.15
ATQL-80G65
DN80
2-1000.120.15
G1002.5-1600.10.15
G1603-2500.10.18
ATQL-100G160DN1003-2500.10.2
G2504-5000.650.35
ATQL-150G400DN1508-6500.760.46
G65015-10000.850.5
ATQL-200G1600DN20032-16000.950.6
Detailed Photos
Installation Instructions

Installation Tips
 

  1. Before installation and use, the user should read this description in detail to ensure the correct installation and reasonable use of the flow meter, so as not to affect the normal operation and measurement accuracy;
  2. Before installing the flow meter, the outlet package should be removed, and granular impurities must be prevented from falling into the measuring room, such as anti-rust oil on the surface of the measuring room, which can be washed with gasoline or kerosene, and impurities in the pipeline should be strictly removed. A filter or filter should be installed upstream of the flow meter to prevent rust slag, welding slag and impurities from entering the measuring room;
  3. When the flow meter is installed, whether the outlet is vertical or horizontal, the rotor axis should be kept horizontal as far as possible. In order to prevent the rust slag and welding slag impurities in the newly installed pipeline from entering the flow meter, the user should first install the transition pipe on the installation position of the flow meter, vent for a period of time (about a week), ensure that there are no large particles of impurities, and then replace the flow meter;
  4. Install the flow meter to ensure that the center of the flow meter is aligned with the center of the pipeline, without misalignment, and that the flow meter is not affected by external forces (including axial and tangential).
Model Selection
ATQL Parameters×××××××××
Size (mm)DN25-DN200mm       
Accuracy1.5% (standard)1
1.0%2
Nominal Pressure1.0MPa1
1.6MPa2
Others3
Body MaterialAluminum AlloyA
Stainless SteelS
Output/
Communication
Pulse1
Pulse+4~20mA3
Pulse+4~20mA+RS4854
Power SupplyBattery Powered1
Battery Powered + External Power DC24V2
Ex-proofWith1
Without2
InstallationHorizontalH
VerticalV
Certifications

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA