Product Description
Gas Lobed Rotor (Roots) Flowmeter widely used in urban gas trade measurement, especially for organs, schools, enterprises and institutions, hotels, restaurants and other large gas users trade measurement. It can also be used for various industrial raw gas main metering, gas distribution station, main gas supply station and other occasions.
Model | Flow Spec | Size (mm) | Flow Range (m³/h) | Start up flow (m³/h) | Max Pressure loss (KPa) |
ATQL-25 | G16 | DN25 | 1-25 | 0.05 | 0.08 |
ATQL-40 | G25 | DN40 | 1-40 | 0.05 | 0.08 |
ATQL-50 | G25 | DN50 | 1-40 | 0.1 | 0.08 |
G40 | 2-65 | 0.1 | 0.1 | ||
G65 | 2-100 | 0.12 | 0.15 | ||
ATQL-80 | G65 | DN80 | 2-100 | 0.12 | 0.15 |
G100 | 2.5-160 | 0.1 | 0.15 | ||
G160 | 3-250 | 0.1 | 0.18 | ||
ATQL-100 | G160 | DN100 | 3-250 | 0.1 | 0.2 |
G250 | 4-500 | 0.65 | 0.35 | ||
ATQL-150 | G400 | DN150 | 8-650 | 0.76 | 0.46 |
G650 | 15-1000 | 0.85 | 0.5 | ||
ATQL-200 | G1600 | DN200 | 32-1600 | 0.95 | 0.6 |



Installation Tips
- Before installation and use, the user should read this description in detail to ensure the correct installation and reasonable use of the flow meter, so as not to affect the normal operation and measurement accuracy;
- Before installing the flow meter, the outlet package should be removed, and granular impurities must be prevented from falling into the measuring room, such as anti-rust oil on the surface of the measuring room, which can be washed with gasoline or kerosene, and impurities in the pipeline should be strictly removed. A filter or filter should be installed upstream of the flow meter to prevent rust slag, welding slag and impurities from entering the measuring room;
- When the flow meter is installed, whether the outlet is vertical or horizontal, the rotor axis should be kept horizontal as far as possible. In order to prevent the rust slag and welding slag impurities in the newly installed pipeline from entering the flow meter, the user should first install the transition pipe on the installation position of the flow meter, vent for a period of time (about a week), ensure that there are no large particles of impurities, and then replace the flow meter;
- Install the flow meter to ensure that the center of the flow meter is aligned with the center of the pipeline, without misalignment, and that the flow meter is not affected by external forces (including axial and tangential).
ATQL | Parameters | ××× | × | × | × | × | × | × |
Size (mm) | DN25-DN200mm | |||||||
Accuracy | 1.5% (standard) | 1 | ||||||
1.0% | 2 | |||||||
Nominal Pressure | 1.0MPa | 1 | ||||||
1.6MPa | 2 | |||||||
Others | 3 | |||||||
Body Material | Aluminum Alloy | A | ||||||
Stainless Steel | S | |||||||
Output/ Communication | Pulse | 1 | ||||||
Pulse+4~20mA | 3 | |||||||
Pulse+4~20mA+RS485 | 4 | |||||||
Power Supply | Battery Powered | 1 | ||||||
Battery Powered + External Power DC24V | 2 | |||||||
Ex-proof | With | 1 | ||||||
Without | 2 | |||||||
Installation | Horizontal | H | ||||||
Vertical | V |