New Silu UPS Uninterruptible Power Supply Cye2K Online 2000va/1600W Built-in Battery Mh12V7ah * 4, Server Voltage Regulation, Power Outage, Silent 220V

Price $95.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 423 people viewed
Quantity
+-
 

New Idea Electric Co.,Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
CYE2K
Single Phase
On-line
Sealed Maintenance Free
Industry
Lighting
Long-acting Machine
Sine Wave Output UPS
Small Type
Decentralized
Xinsilu
15 Minutes(Customizable)
Four 7ah Batteries
ISO9001-ISO45001-ISO14001
72V
450*192*335mm
NICEA
Paper Box with Wooden Box
450*192*335MM
China
3101
Product Description
Tech nical parameters
ModelWall-mounted typeVertical type
1KVA2KVA3KVA1KVA2KVA3KVA
Capacity1KW2KW3KW1KW2KW3KW
Input

Voltage
Range
Minimum switching voltageAt 50% load, 11OVAC +3%; at 100% load, 176VAC+3 %
Minimum recovery voltageMinimum switching voltage +10V
Maximum switching voltage300VACI3 %
Maximum recovery voltageMaximum switching voltage -10V
Frequency Range40-60HZ@50HZ system/50-70HZ@60HZ system
PhaseL+ N+PE
Power Factor100% load z0.99
Output
Output Voltage208/220/230/240VAC
Output Voltage AccuracyI1%
Frequency Range
(synchronization range)
40-60hz@50HZsystem/50-70HZ@60HZsystem
Frequency Range (battery mode)50hz+0.1 HZor60HZ+0.1 HZ

Overload
AC Mode30min@102%-110%Ioad, 10min@110%-130%load 30s@130%-150%Ioad, 500ms@>150 %Ioad
Battery Mode10min@102%-110%Ioad, 1min@110%-130%load 10s@130%-150%Ioad, 500ms@> 150 %Ioad
Current peak ratio3:1 (Maximum)
Harmonic distortion2% ( linear load ) , 5%(non-linear load)
Switching timeMains  BatteryOms
Inverter Bypass0ms
Effectiveness
AC Mode95%
Battery Mode94.8% (20pcs batteries)
Battery

Standard
Battery Number2 pcs4 pcs6 pcs2 pcs4 pcs6 pcs
Charging Currentdefault 1A
Charging Voltage13.65 x NI1 %

Long Run
Battery Number3 pcs6 pcs8 pcs3 pcs6 pcs8 pcs
Charging CurrentPreset: 6A110%, 1-12A optional
Charging Voltage13.65x N*1%
Apperance
StandardSize
Long Width High(mm)
310"438"88380"438"88506"438"88284"145"213398"145"213450"192"335
Long RunSize
Long Width High(mm)
310"438"88380"438"88380"438"88284"145"213398"145"213398"145"213
Environment
Operating Temperature0-40°C
Operating Moisture< 95%And no condensation
Operating Altitude< 1000m""
Noiseless than 50dB@1Meter
Management
SmartRS-232Suppon Windows@2000/2003/XP/Vista/2008. Windows@7/8, Linux. Unix and MAC
Optional SNMPSupport for power management by SNMP administrator and web browser.
Warning Code Description
Warning CodeEnglish MeaningLinked ActiveTriggering ConditionsRecovering Conditions

1
Battery is not connectedWarning,
battery discharge
Battery voltage less than 8V/PCSRecoverab Ie(10V/PCS)

2
Low voltage in batteryWarning, battery test models return to main modelDefault 11.2/pcs, Custom settings 10.5-14V/PCS(2)Recoverable (Action point
+0.2V/pcs)

3
Charging short circuiWarning,
No charging to batteries
The battery voltage is lower than 5V/pcs,current is more than 4A
Unrecoverab ie



4


Mains L/N reverse connectionor the groundwire is not connected



Warning



Hardware trigger
Reco nn ect the L/ N of the ma in s powe r afte r powe r fa iIure , ch eck wheth er the gro u nd wire is con n ected , or send a co mm u n icatio n com ma n d to p ro hi b it L/N reverse conn ecti o n

8

High voltage in battery
Warning,
battery discharge

Default 11.2/pcs, Custom settings +0.4V/PCS
Recoverable (DefauIt13.7V
/PCS,custom settings +0.4V
/pcs)

9

Chargerfa ilure

Warning
After 5 minutes of charging, the battery voltage is still less than 10VRecoverable (battery voltage more than 10.5V)

10

Over-temperature warning
Warning,
battery discharge
PFC or INV temperature sensor is higher than 80 degrees CelsiusRecoverab ie (The temperature sensor is below 75 degrees C elsius)
12Fan failureWarningNo fan speed signal detectedRecoverable

13

Mains disconnect

Warning
The difference between the mains voltage and the bypass voltage is greater than 100V
Recoverable
14EEPROM failureWarningEEPROM read and write failedUnrecoverable

18
Inverter output overvoltageWarning,
battery discharge

load more than 102%
Recoverable
(overload less than 97%)

22
Overload lock in bypass
Warning
3 times of overload transfer to bypass mode in 30 minutes
Manual boot can be restored
23EPO actionWarning,
battery discharge
 Recoverable
24Maintenance switch actionWarningShort circuit of CN4 terminal on control boardRecoverable
The fault code table
Fault codeEnglish meaningRelated actionsTrigg er conditionRecovery condition
1Busbar boost soft start failureTurn to fault modeWhen the busbar starts soft, the 30S cannot reach 380VUnrecoverable
2Busbar over voltageTurn to fault modeWhen the busbar is above 450V,it will lasts 5sUnrecoverable
3Busbar und ervoltageTurn to fault modeWhen the busbar is below 200V, it will lasts 400msUnrecoverable
4DC boost failureTurn to fault modeDC-DC hardware protection that triggered the exceptionUnrecoverable
gBattery relay short circuitTurn to fault modeBattery voltage is greater than 310V and lasts for 4sUnrecoverable
9Busbar soft start relay failureTurn to fault modeThe bus relay is still below SOV after 5s soft startUnrecoverable
10Bus bar short circuitTurn to fault modeDuring normal operation, the mother is instantaneously below 180VUnrecoverable

17
Inverter soft StaFt
failure

Turn to fault mode
After inverting soft start 40s, the rated output voltage cannot be reached, or after inverting soft 2s, the inverter voltage is still less than 20V.
Unrecoverable
18Inverter output overvoltageTurn to fault modeThe inverter voltage is higher than 276V and lasts 400msUnrecoverable
19Inverter output undervoltageTurn to fault modeThe inverter voltage is below 130V and lasts 400msUnrecoverable
20Inverter short circuitTurn to fault modeThe inverter voltage is less than SOV, the current is hipher than 20A, andlasts 4sUnrecoverable
26Negative power protectionTurn to fault modeInverter power is less than -2400W for 20ms, or -800W for 120msUnrecoverable

33
Inverter relay open
Turn to fault mode
When the inverter relay is cIosed,the difference between the inverter voltage andthe output voltage exceeds 30V for 160ms
Unrecoverable

34

Inverter rela short circuity

Turn to fault mode
When the bypass relay is cIosed,the inverter relay is disconnected and the inverter bridge is not working the difference between the inverter voltage and the bypass voltage is
less than 30V

Unrecoverable

35
Bypass FBIay open
Turn to fault mode
When the bypass relay is cIosed,the difference between the bypass voltage and the output voltage exceeds 30V for 160ms
Unrecoverable

36

Bypass relay short circuit

Turn to fault mode
When the bypass relay and the inverter relay are disconnected,the difference etween the output voltage and the bypass voltage is less
than 30V for 160ms

Unrecoverable

37
Input and O t Ut reversed 'J p
Turn to fault mode
When the bypass relay and the inverter relay are disconnected,the bypass voltage is less than 20V, but the output voltage is greater than 150V
Unrecoverable
39Charger short circuitTurn to fault modeThe battery voltage is less than SOV and the charging current is higher than 4AUnrecoverable
66Overload faultTurn to fault modeThe load exceeds the specificationUnrecoverable
67Reverse batteryTurn to fault modeThe battery input is reversedUnrecoverable
68Model recognition errorTurn to fault modeUndefined machine modelUnrecoverable
73No bootloaderTurn to fault modeNo boot programUnrecoverable

FAQ

Q: Are you a factory or a trading company?

A: We are a factory with a 10 year production and sales history in AC/DC power supply, uninterruptible power supply. We warmly welcome your visit.

Q: What is the delivery time?
A: Generally, the delivery time is between 7-30 days after receiving payment from the customer.
Accurate information depends on the product and quantity, and we can further communicate on this.

Q: Do you have a minimum order quantity requirement?
A: The minimum order quantity for most products is 1 set. The minimum order quantity for individual UPS is 10

Q: How long is your warranty period?
A: We provide customers with a 2-year warranty and a 1-year warranty.

Q: Can you provide customized services?
A: Yes. Since 20014, we have been involved in OEM and ODM projects.
So that we can provide professional customized services for our customers.

Q: Do you have after-sales service?

A: Yes, we have an after-sales service team.
Our after-sales engineers can provide support and guidance through video or phone when needed.

Q: Do you conduct testing after completing production?
A: Yes, our production engineer team will conduct testing upon completion of the goods, and we will provide the testing information to customers for reference before delivery.
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA