Insulated
Solid
Copper
PVC
PVC
Round Wire
Nmd90 Cable
cUL
300V
14/2 12/2 10/2 8/2
2+1, 3+1
PVC
White, Orange, Red, Black
T90
Canada
Plastic or Drum
Standard Export Drum
14awg 12awg 10awg 8awg 6awg
Tangshan, Hebei Province
8544492100
Product Description
300V 14/2 12/2 flat NMD90 cable with Cul certificate for Canadian market
NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations. The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C for two-conductor cables and -10°C for three-conductor cables (with suitable handling procedures). Material should be properly stored above 0°C for 24 hours prior to installation. The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code1 for further information related to applications




NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations. The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C for two-conductor cables and -10°C for three-conductor cables (with suitable handling procedures). Material should be properly stored above 0°C for 24 hours prior to installation. The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code1 for further information related to applications
ASTM
CSA C22.2 No. 48 (non-metallic sheathed cable)
Canadian Electrical Code
Conductors:
Solid 14-10 AWG soft, uncoated copper, per ASTM-B3
Stranded 8 AWG conductor and larger uncoated, copper ASTM-B8
Insulation:
Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90°C in dry locations.
Grounding Conductor:
Soft, uncoated copper per ASTM-B3 and/or ASTM-B8
Jacket:
A 30-mil, color-coded, PVC jacket is applied over the completed assembly as follows:
14 AWG White I 12 AWG Yellow I 10 AWG Orange I 8 AWG Black I 6 AWG Black
Size (AWG) | Number of Strands | Ground Wire Size | Insulation Thickness (in) | Allowable Ampacity (Amps)* | Outside Diameter (in) | Approximate Net Weight (lbs/1000 ft) | |
PVC | Nylon | ||||||
14/2 G | Solid | 14 | 0.015 | 0.004 | 15 | 0.170 x 0.390 | 56 |
12/2 G | Solid | 12 | 0.015 | 0.004 | 20 | 0.160 x 0.450 | 82 |
10/2 G | Solid | 10 | 0.020 | 0.004 | 30 | 0.210 x 0.493 | 123 |
8/2 G | 7 | 10 | 0.030 | 0.005 | 40 | 0.290 x 0.580 | 185 |
6/2 G | 7 | 10 | 0.030 | 0.005 | 55 | 0.330 x 0.695 | 256 |
14/3 G | Solid | 14 | 0.015 | 0.004 | 15 | 0.170 x 0.450 | 74 |
12/3 G | Solid | 12 | 0.015 | 0.004 | 20 | 0.345 | 107 |
10/3 G | Solid | 10 | 0.020 | 0.004 | 30 | 0.430 | 165 |
8/3 G | 7 | 10 | 0.030 | 0.005 | 40 | 0.555 | 251 |
6/3 G | 7 | 10 | 0.030 | 0.005 | 55 | 0.612 | 352 |
4/3 G | 7 | 8 | 0.040 | 0.006 | 70 | 0.820 | 565 |
2/3 G | 7 | 8 | 0.040 | 0.006 | 95 | 0.945 | 841 |
**14/4 G & 14/2-2 G | Solid | 14 | 0.015 | 0.004 | 12 | 0.345 | 90 |
**12/4 G & 12/2-2 G | Solid | 12 | 0.015 | 0.004 | 16 | 0.385 | 132 |
**10/4 G | Solid | 10 | 0.020 | 0.004 | 30 | 0.540 | 205 |