AC60
45-67/100/120/200/240Hz
Single/Three
1.5 Percent
Spwm Switch Type
Yes
50Hz/60Hz
Hybrid Load
BOS
Wooden Crate
customizable
Jinan China
Product Description

Product Overview
The AC60 series is a power supply that converts the mains power into the required voltage and frequency through a power conversion circuit. Its main features are to provide pure and reliable sine wave power output, low harmonic distortion, high stability of frequency and voltage regulation. It can simulate the output characteristics of different voltages and frequencies around the world, and is suitable for applications such as factory production lines, quality verification, and research and development.
The AC60 series is a power supply that converts the mains power into the required voltage and frequency through a power conversion circuit. Its main features are to provide pure and reliable sine wave power output, low harmonic distortion, high stability of frequency and voltage regulation. It can simulate the output characteristics of different voltages and frequencies around the world, and is suitable for applications such as factory production lines, quality verification, and research and development.
Products features
1.High overload capacity.The power unit is modular and can withstand 2 times the rated current without causing a voltage drop;
2.Fast and dynamic response:The transient change of the sudden load voltage is < 1%, and the recovery time is < 20ms;
3.Good human-computer interaction:7-inch, resolution 800*480 touch operation display;
4.Strong anti-interference:It adopts optical fiber drive control, which has strong anti-electromagnetic interference ability and reliability;
5.High level of protection:The surface of the equipment cabinet is electrostatic sprayed, and the PCB is sprayed with conformal paint and glue.
1.High overload capacity.The power unit is modular and can withstand 2 times the rated current without causing a voltage drop;
2.Fast and dynamic response:The transient change of the sudden load voltage is < 1%, and the recovery time is < 20ms;
3.Good human-computer interaction:7-inch, resolution 800*480 touch operation display;
4.Strong anti-interference:It adopts optical fiber drive control, which has strong anti-electromagnetic interference ability and reliability;
5.High level of protection:The surface of the equipment cabinet is electrostatic sprayed, and the PCB is sprayed with conformal paint and glue.


Application industry
It is used in various automation systems, laboratories, measurement rooms, etc. for various precision tests for AC source effect testing, and can also be used as a centralized power supply for factories and laboratories.
It is used in various automation systems, laboratories, measurement rooms, etc. for various precision tests for AC source effect testing, and can also be used as a centralized power supply for factories and laboratories.
1.
Device model | AC60 -11005 | AC60 -11010 | AC60 -11030 | AC60 -11050 | AC60 -11100 | AC60 -11150 | AC60 -11200 | AC60 -11300 |
Rated power | 0.5kVA | 1kVA | 3kVA | 5kVA | 10kVA | 15kVA | 20kVA | 30kVA |
Input AC indicators | ||||||||
Power supply system | Single phase two wire+PE | |||||||
Voltage range | 220V ( ±15%) | |||||||
Frequency range | 50/60Hz ( ±10%) | |||||||
Characteristics of output AC | ||||||||
Power supply system | Single phase two wire | |||||||
Voltage range | Low:0~150VL -N ,HIgh:0~300VL -N | |||||||
Current range(Low) | 4A | 9A | 27A | 45A | 90A | 136A | 181A | 272A |
Current range(HIgh) | 2A | 4A | 13A | 22A | 45A | 68A | 90A | 136A |
Frequency range | Fixed frequency:50/60Hz ,frequency modulation:45~65Hz | |||||||
Source effect | ≤0.1%F.S | |||||||
Load effect | ≤0.1%F.S | |||||||
Voltage accuracy | ≤0.1%F.S | |||||||
Frequency accuracy | ≤0.01%F.S | |||||||
Voltage harmonics | ≤2% | |||||||
Response time | ≤5ms | |||||||
Equipment efficiency | ≥90% | |||||||
Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | |||||||
System function | ||||||||
Oline adjustment function | Adjustable output voltage and frequency online | |||||||
Quick setting function | Customizable settings for multiple sets of output voltage and frequency | |||||||
Memory function | After power failure recovery, the last output mode and parameters can be remembered | |||||||
Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | |||||||
Display and Communication | ||||||||
Local operation | Digital LED | LCD display screen | ||||||
Display resolution | Voltage:0.1V , Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | |||||||
Display accuracy | Voltage:0.1%F.S , Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | |||||||
Remote communication | No communication | RS 485/LAN | ||||||
Communication Protocol | No communication protocol | standard Modbus RTU/Modbus TCPIP | ||||||
Safety | ||||||||
Pressure Resistance Strength | 2000Vdc/60s/no breakdown | |||||||
Insulation Resistance | ≥20MΩ@500Vdc | |||||||
Grounding Resistance | ≤100mΩ | |||||||
Noise | ≤65dB(A) | |||||||
Usage environment | ||||||||
Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | |||||||
Cooling Method | Fan forced air cooling | |||||||
Protection Level | IP 21 | |||||||
Altitude | ≤5000m@>2000m derating use | |||||||
Size(W*D*H)mm | 440*460*133 (Including footings) | 440*460*133 (Including footings) | 440*460*242 (Including footings) | 350*560*675 (Including moving wheels) | 400*660*800 (Including moving wheels) | 400*660*800 (Including moving wheels) | 500*820*1100 (Including moving wheels) | 500*820*1100 (Including moving wheels) |
2.
Device model | AC60 -31100 | AC60 -31150 | AC60 -31200 | AC60 -31300 | AC60 -31450 | AC60 -31600 | AC60 -311000 |
Rated power | 10kVA | 15kVA | 20kVA | 30kVA | 45kVA | 60kVA | 100kVA |
Input AC indicators | |||||||
Power supply system | Three-phase four-wire+PE | ||||||
Voltage range | 380V ( ±15%) | ||||||
Frequency range | 50/60Hz ( ±10%) | ||||||
Characteristics of output AC | |||||||
Power supply system | Single phase two wire | ||||||
Voltage range | Low:0~150VL -N ,HIgh:0~300VL -N | ||||||
Current range(Low) | 90A | 136A | 181A | 272A | 409A | 545A | 909A |
Current range(HIgh) | 45A | 68A | 90A | 136A | 204A | 272A | 454A |
Frequency range | Fixed frequency:50/60Hz ,frequency modulation:45~65Hz | ||||||
Source effect | ≤0.1%F.S | ||||||
Load effect | ≤0.1%F.S | ||||||
Voltage accuracy | ≤0.1%F.S | ||||||
Frequency accuracy | ≤0.01%F.S | ||||||
Voltage harmonics | ≤2% | ||||||
Response time | ≤5ms | ||||||
Equipment efficiency | ≥90% | ||||||
Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | ||||||
System function | |||||||
Oline adjustment function | Adjustable output voltage and frequency online | ||||||
Quick setting function | Customizable settings for multiple sets of output voltage and frequency | ||||||
Memory function | After power failure recovery, the last output mode and parameters can be remembered | ||||||
Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | ||||||
Display and Communication | |||||||
Local operation | Digital LED | LCD display screen | |||||
Display resolution | Voltage:0.1V , Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | ||||||
Display accuracy | Voltage:0.1%F.S , Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | ||||||
Remote communication | RS 485/LAN | ||||||
Communication Protocol | standard Modbus RTU/Modbus TCPIP | ||||||
Safety | |||||||
Pressure Resistance Strength | 2000Vdc/60s/no breakdown | ||||||
Insulation Resistance | ≥20MΩ@500Vdc | ||||||
Grounding Resistance | ≤100mΩ | ||||||
Noise | ≤65dB(A) | ||||||
Usage environment | |||||||
Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | ||||||
Cooling Method | Fan forced air cooling | ||||||
Protection Level | IP 21 | ||||||
Altitude | ≤5000m@>2000m derating use | ||||||
Size(W*D*H)mm | 400*650*800 (Including moving wheels) | 400*650*800 (Including moving wheels) | 500*820*1105 (Including moving wheels) | 500*820*1105 (Including moving wheels) | 520*1160*1355 (Including moving wheels) | 520*1160*1355 (Including moving wheels) | 520*1160*1355 (Including moving wheels) |
3.
Device model | AC60 -33100 | AC60 -33200 | AC60 -33300 | AC60 -33450 | AC60 -33600 | AC60 -33900 | AC60 -331000 | AC60 -331200 | AC60 -331500 | |
Rated power | 10kVA | 20kVA | 30kVA | 45kVA | 60kVA | 90kVA | 100kVA | 120kVA | 150kVA | |
Input AC indicators | ||||||||||
Power supply system | Three phase four wire+PE | |||||||||
Voltage range | 380V ( ±15%) | |||||||||
Frequency range | 50/60Hz ( ±10%) | |||||||||
Characteristics of output AC | ||||||||||
Power supply system | Three phase four wire | |||||||||
Voltage range | Low:0~150VL -N ,HIgh:0~300VL -N | |||||||||
Current range(Low) | 30A | 60A | 90A | 136A | 181A | 272A | 303A | 363A | 454A | |
Current range(HIgh) | 15A | 30A | 45A | 68A | 90A | 136A | 151A | 181A | 227A | |
Frequency range | Fixed frequency:50/60Hz ,frequency modulation:45~65Hz | |||||||||
Source effect | ≤0.1%F.S | |||||||||
Load effect | ≤0.1%F.S | |||||||||
Voltage accuracy | ≤0.1%F.S | |||||||||
Frequency accuracy | ≤0.01%F.S | |||||||||
Voltage harmonics | ≤2% | |||||||||
Response time | ≤5ms | |||||||||
Equipment efficiency | ≥90% | |||||||||
Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | |||||||||
System function | ||||||||||
Oline adjustment function | Adjustable output voltage and frequency online | |||||||||
Quick setting function | Customizable settings for multiple sets of output voltage and frequency | |||||||||
Memory function | After power failure recovery, the last output mode and parameters can be remembered | |||||||||
Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | |||||||||
Display and Communication | ||||||||||
Local operation | LCD display screen | |||||||||
Display resolution | Voltage:0.1V ,Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | |||||||||
Display accuracy | Voltage:0.1%F.S ,Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | |||||||||
Remote communication | RS 485/LAN | |||||||||
Communication Protocol | standard Modbus RTU/Modbus TCPIP | |||||||||
Safety | ||||||||||
Pressure Resistance Strength | 2000Vdc/60s/no breakdown | |||||||||
Insulation Resistance | ≥20MΩ@500Vdc | |||||||||
Grounding Resistance | ≤100mΩ | |||||||||
Noise | ≤65dB(A) | |||||||||
Usage environment | ||||||||||
Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | |||||||||
Cooling Method | Fan forced air cooling | |||||||||
Protection Level | IP 21 | |||||||||
Altitude | ≤5000m@>2000m derating use | |||||||||
Size(W*D*H)mm | 500*820*1105 (Including moving wheels) | 500*820*1105 (Including moving wheels) | 520*1160*1355 (Including moving wheels) | 520*1160*1355 (Including moving wheels) | 650*1420*1470 (Including moving wheels) | 650*1420*1470 (Including moving wheels) | 650*1420*1470 (Including moving wheels) | 650*1420*1470 (Including moving wheels) | 650*1420*1470 (Including moving wheels) |
4.
Device model | AC60 -332000 | AC60 -333000 | AC60 -334000 | AC60 -336000 | AC60 -338000 | AC60 -3310000 | AC60 -3312000 | AC60 -3316000 | AC60 -3320000 |
Rated power | 200kVA | 300kVA | 400kVA | 600kVA | 800kVA | 1000kVA | 1200kVA | 1600kVA | 2000kVA |
Input AC indicators | |||||||||
Power supply system | Three phase four wire+PE | ||||||||
Voltage range | 380V ( ±15%) | ||||||||
Frequency range | 50/60Hz ( ±10%) | ||||||||
Characteristics of output AC | |||||||||
Power supply system | Three phase four wire+PE | ||||||||
Voltage range | Low:0~150VL -N ,HIgh:0~300VL -N | ||||||||
Current range(Low) | 303A | 454A | 606A | 911A | 1215A | 1519A | 1823A | 2431A | 3038A |
Frequency range | Fixed frequency:50/60Hz ,frequency modulation:45~65Hz | ||||||||
Source effect | ≤0.1%F.S | ||||||||
Load effect | ≤0.1%F.S | ||||||||
Voltage accuracy | ≤0.1%F.S | ||||||||
Frequency accuracy | ≤0.01%F.S | ||||||||
Voltage harmonics | ≤2% | ||||||||
Response time | ≤5ms | ||||||||
Equipment efficiency | ≥90% | ||||||||
Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | ||||||||
System function | |||||||||
Oline adjustment function | Adjustable output voltage and frequency online | ||||||||
Quick setting function | Customizable settings for multiple sets of output voltage and frequency | ||||||||
Memory function | After power failure recovery, the last output mode and parameters can be remembered | ||||||||
Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | ||||||||
Display and Communication | |||||||||
Local operation | LCD display screen | ||||||||
Display resolution | Voltage:0.1V , Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | ||||||||
Display accuracy | Voltage:0.1%F.S , Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | ||||||||
Remote communication | RS 485/LAN | ||||||||
Communication Protocol | standard Modbus RTU/Modbus TCPIP | ||||||||
Safety | |||||||||
Pressure Resistance Strength | 2000Vdc/60s/no breakdown | ||||||||
Insulation Resistance | ≥20MΩ@500Vdc | ||||||||
Grounding Resistance | ≤100mΩ | ||||||||
Noise | ≤65dB(A) | ||||||||
Usage environment | |||||||||
Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | ||||||||
Cooling Method | Fan forced air cooling | ||||||||
Protection Level | IP 21 | ||||||||
Altitude | ≤5000m@>2000m derating use | ||||||||
Size(W*D*H)mm | 1550*850*1985 (Including moving wheels) | 1550*850*1985 (Including moving wheels) | 1910*1160 *1940 | 3100*900 *2080 | 3100*900 *2080 | 4900*1600 *2080 | 4900*1600 *2080 | 4900*1600 *2080 | 4900*1600 *2080 |



Shandong BOS Energy Technology Co., Ltd. (referred to as BOS) is a high-tech enterprise in Shandong Province specializing in the research and development, manufacturing, sales, and service of power equipment. For more than 20 years, BOS has focused on power electronic conversion technology. Committed to providing customers with the best system solutions, our products include AC/DC test power supplies, AC/DC power supplies, shore power, and new energy product lines. The production base covering an area of 20000 square meters, built in 2010, has an annual output value of over 100 million yuan. BOS is one of the most influential "leading enterprises" among domestic high-power power supply manufacturers.
BOS has multiple national patents in the field of power supply and has passed international ISO9001 quality system certification, ISO14001 environmental management system certification, and ISO45001 occupational health and safety management system certification; And has successively won honors such as specialized and innovative, gazelle enterprise, and high-tech enterprise, as well as awards such as "Best Supplier of Small and Medium Power Bidirectional Energy Storage Inverters"; Establishing an energy conversion and energy storage engineering technology center; It is a member unit of the China Power Association, a member unit of the Port Science and Technology Committee, an executive director unit of the China Renewable Energy Association, and a qualified supplier for procurement by the Chinese Academy of Sciences.













1.Q:Are you manufacturers?
--Yes, we have an independent factory covering an area of over 20000 square meters.
2. Q:Can the power of the product be customized?
--Yes, we can customize products according to your needs.
3.Q: Is there any guarantee for after-sales service after purchasing products from your store?
--Yes,during the warranty period, we will regularly visit customers and collect feedback information to continuously improve the quality of our company's products and services.
4.Q:How is your production management and quality control?
--Our company's production process for all products follows ISO9001, with professional operators controlling each production step. Quality inspectors also conduct regular inspections, and after each product undergoes performance testing, a comprehensive quality inspection will be conducted.